5. maiNteNaNce
5.1.
When the lift is not in use, it must be returned to its lowest position to minimise ram and piston corrosion.
5.2.
Keep the lift clean and wipe off any oil or grease. lubricate all moving parts..
5.3.
Before each use check all parts. if any part of the lift is damaged or suspect, remove lift from service and take necessary action to
repair.
do Not use the lift if it is believed to have been subjected to abnormal load or shock. inspect and take appropriate action.
8
5.4.
check the ram and piston periodically for signs of corrosion. clean exposed areas with a clean oiled cloth.
5.5.
topping up the oil. top up the oil as in section 4.2. use only a good quality jack oil, such as sealey Jack oil.
do Not use any other fluid such as: brake fluid, automatic transmission fluid or engine oil.
8
6. troubleShootiNg
symPtom
Jack will not lift load
Jack will lift but not retain pressure
Jack will lift but not lower after unloading
Poor lift performance
importaNt: No reSpoNSibility iS accepted for iNcorrect uSe of the lift.
Hydraulic products are repaired by local service agents only. We have service/repair agents in all parts of the uK.
DO NOT return the product to us. Please call us on 01284 757500 to obtain the address and telephone number of your local agent.
If the product is under guarantee please contact your dealer.
de-commissioning: should the lift become completely unserviceable, draw off the oil into an approved container and dispose of the lift and
the oil according to local regulations.
parts support is available for this product. to obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
environmental protection
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
importaNt: no liability is accepted for incorrect use of this product.
WarraNty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack sealey limited
PossiBle course
release valve not tightly closed
overload condition
Hydraulic unit malfunction
foot release valve not tightly closed
overload condition
Hydraulic unit malfunction
reservoir over filled
linkage binding
fluid level low
Air trapped in system
sole uK distributor, sealey Group.
Kempson Way, suffolk Business Park,
Bury st. edmunds, suffolk.
iP32 7Ar
Original Language Version
solution
close foot release valve
remove / release load
service hydraulic unit
close foot release valve fully
remove / reduce load
service hydraulic unit
drain fluid to correct level
clean and lubricate moving parts
ensure proper fluid level
Bleed system
01284 757500