Vante SEBRA MINI 2380 Operation Manual

Hand-held tube sealer power source

Advertisement

operation manual
VT-108723-US
MINI™ Model 2380
Hand-Held Tube Sealer
Power Source
VANTE INC
IGNITING INNOVATION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SEBRA MINI 2380 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vante SEBRA MINI 2380

  • Page 1 VT-108723-US MINI™ Model 2380 Hand-Held Tube Sealer Power Source VANTE INC IGNITING INNOVATION...
  • Page 2 © 2007–2011, 2017 Vante Inc. All rights reserved.
  • Page 3 Any information and descriptions contained in this manual may not be reproduced, released to the general public, or used in conjunction with any professional instruction without written consent of Vante, USA. Please direct any written inquiries to the appropriate address. USA Location...
  • Page 4 ® ® ™ Vante SEBRA MINI Tube Sealer Power Source P/N VT-108723-US, Manual revision: C...
  • Page 5: Table Of Contents

    Chapter 5, Cleaning and maintenance Cleaning and maintenance ................23 Cleaning the power source case ..............23 Troubleshooting and maintenance ............24 CUSTOMER SERVICE ..................25 Services ....................25 ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 6 Figure 3-5, Attachment of RF Power Cable ..........15 Figure 4-1, Properly Removing the Battery Using the Strap ......19 Figure 4-2, Properly Removing the Battery by Sliding ........19 ® ® ™ Vante SEBRA MINI Tube Sealer Power Source P/N VT-108723-US, Manual revision: C...
  • Page 7: Preliminary Information

    Chapter 1 Preliminary information Document This manual is a guide for the operation, care, and maintenance of the Vante ® scope SEBRA Model 2380 MINI™ Hand-Held Tube Sealer Power Source. ® Intended This manual is intended for use by personnel having technical skills and a...
  • Page 8: Symbols Found On The Device

    Identifies any terminal intended for connection to an external conductor, for protection against electrical shock in case of a fault. Power ON Power OFF Fuse Serial Number Catalog Number Manufacturer ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 9: Device Specifications

    Maximum relative humidity 70% Pollution degree Warning: Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 10: Electrical Specifications

    100-240VAC, 50-60 Hz Output 15VDC, 55mA and 1.4A RF power output 40 watts minimum into matched 50Ω load, at initial power up Primary 40.68±0.02 MHz frequency ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 11: Product Overview

    Chapter 2 Product overview The Vante SEBRA Model 2380 MINI™ Hand-Held Tube Sealer Power ® ® Source (Sealer) is a compact, portable, battery powered device that employs SMART™ electronics (which detect the end of the seal and arcing problems) to generate radio frequency (RF) to make uniform, quality seals on a variety of tubing sizes without power adjustment by the user.
  • Page 12 This detection circuit is activated when the battery voltage has dropped to a point in which a limited number of good seals remain. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 13: Component Identification

    The serial plate (2-3), located on the underside of the RF power source, indicates the model number and serial number of the unit. ® Refer to the serial number when contacting Vante Customer Care Center. See Table 2-1, “2380 Sealer Component Functions,” on page 8 for a complete description of the functions of the indicated items.
  • Page 14: Figure 2-3, Serial Plate For Model 2380

    Turns battery power "on" or "off". Rocker type switch located on the power interface panel of the RF power source next to the RF ready light. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 15: Operating Environment

    C). To ensure optimal performance, it is recommended that the sealer be acclimated to the ambient environmental operating temperature for approximately one hour prior to use. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 16: Pvc Tubing Size Categories

    MEDIUM (typically, blood bag tubing) size only. Note: To perform continuous sealing on tubing of SMALL and LARGE sizes, a different sealer may be required. Contact Vante for more information. "Maximum" mode, which may be used for tubing of MEDIUM and LARGE sizes only, refers to sealing in which a prescribed maximum number of seals is made at a rapid, repetitive rate, followed by a specified period of no Sealer activity.
  • Page 17: Duty Cycle

    1 minute 40 seconds, then none for 4 minutes Maximum 10 Large 6 seconds seals in 1 minute, then none for 10 minutes ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 18: Seal Spacing

    (2.5 cm) to avoid rupture of the tubing due to pressure build-up. Warning: Never attempt to make segmentation seals closer than recommended without validating for seal integrity. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 19: Setup And Sealing Procedure

    Setup and sealing procedure 1. Remove the components from their protective shipping containers and ® visually inspect them for obvious damage. Contact Vante Customer Care Center if any damage is found. Note: If possible, retain shipping containers and packing materials for future use.
  • Page 20: Figure 3-2, Battery Connector Location

    Figure 3-3, Properly Installing the Battery 6. Once the battery is fully seated, engage the RF power source connector to the battery connector. See 3-4. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 21: Figure 3-4, Battery To Power Source Connection

    Warning: Do NOT attempt to use any other length or type of RF power cable. Unauthorized substitution of the RF power cable may result in malfunction of the Power Source and will void the warranty! ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 22 Warning: Never use the Power Source in the presence of flammable anesthetics. A potential explosion hazard may exist if arcing should occur in the presence of such compounds. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 23: Battery Replacement

    12V NiCad battery pack. The battery pack will provide approximately 1500 seals on typical blood bag tubing when fully charged and sealing system is properly tuned. Caution: Use only with battery packs equipped with a Positive Thermal Cutout (PTC) device and approved for use with Vante SEBRA ® ®...
  • Page 24: Figure 4-1, Properly Removing The Battery Using The Strap

    Figure 4-2, Properly Removing the Battery by Sliding 3. Install a fully charged battery pack as described in Chapter 3. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 25: Battery Charging

    "ON" indicator light flashes, leave battery pack on charger for one hour. If amber charge status light still fails to illuminate after one hour, disconnect battery pack from charger and contact Vante Customer Care Center for battery pack replacement. 3. Leave battery pack on battery charger until completely charged. Battery pack is completely charged when amber charge status indicator light flashes every 1/8-second.
  • Page 26 Caution: If Pending Mode period (amber charge status light flashes every 1½ second) exceeds one hour, disconnect battery pack from charger and contact Vante’s Customer Care Center for battery pack replacement. 5. Disconnect the battery pack from the charger and reinstall into the RF power source (see Chapter 3) or set aside as a back up.
  • Page 27: Cleaning And Maintenance

    The fluids may run into the electronic components and cause contamination of the electronics and subsequent unit malfunction. Never immerse the power source in any liquid. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 28: Troubleshooting And Maintenance

    Troubleshooting Troubleshooting activities The following table provides simple maintenance activities that may resolve maintenance device issues. If the problem continues to occur, contact the local Vante representative. Table 5-1, Troubleshooting guide Problem Cause Action No RF power out. Cables not properly Be sure all connections connected.
  • Page 29: Customer Service

    In any event, contact the local Vante representative. USTOMER SERVICE Services Clinical training The local Vante representative will provide staff training upon delivery of the equipment and should be contacted to organize further instruction if needed. Repair service Vante maintains a worldwide network of company-trained service representatives responsible for responding to technical needs concerning equipment.
  • Page 30 ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...
  • Page 31: General Information

    RF energy. However, misuse or direct contact between human tissue tissue and RF electrode(s) can result in severe RF burns. There is no evidence that Vante RF instruments interfere with the function of RF effects on modern cardiac pacemakers.
  • Page 32 Vante Inc. 3480 E. Britannia Dr. Suite 120 Tucson, AZ 85706 USA www.vante.com...
  • Page 33 © 2007-2011, 2017 Vante Inc. ® ® ™ P/N VT-108723-US, Manual revision: C Vante SEBRA MINI Tube Sealer Power Source...

Table of Contents