Commissioning
4.6 Commissioning with the operator panel
4.6.2

BOP controls and displays

How to use the BOP
Table 4- 4
Key
72
Operator controls of the Basic Operator Panel and its functions
Function
Status LED
Parameter access
Increase displayed
values
Decrease displayed
values
Function key
Start motor
Stop motor
Change direction of
rotation
Jog mode
Function / result
Shows parameter numbers, values, and physical units of
measure.
This button allows you to access the parameter list.
r _ _ _ _ read-only parameters: for display only
P_ _ _ _ write parameters: these can be changed
This button allows you to scroll forwards in the parameter
list;
This button allows you to scroll backwards in the parmeter
list.
The function of this button varies depending on the data
displayed:
If a parameter number is displayed and you press this
button once briefly, you can return to the start of the
parameter list r0000.
If a parameter value is displayed and you press this
button once briefly, the cursor jumps to the next position
(e.g. in a multi-digit number). This allows you to change a
decimal number digit by digit, for example.
If an alarm or a fault message is displayed and you press
this button once briefly, this acknowledges the message.
Press this button to start the motor.
In the factory setting, this button is not active:
activate with P0700 = 1
Press this button to stop the motor.
OFF2 is always activated: Press twice briefly or press
once for longer: The motor coasts to a standstill.
In the factory setting, OFF1 is not active.
To activate it, set P0700 = 1.
When you press this button, the direction of motor rotation
is reversed (CW/CCW).
In the factory setting, this button is not active.
To activate it, set P0700 = 1.
Run the motor in jog mode. The motor rotates at a
predefined speed for as long as this key is pressed (and
kept down).
In the factory setting, this button is not active.
To activate it, set P0700 = 1.
CU240S and CU240E Control Units, FW 3.2
Operating Instructions, 03/2009, A5E02440075B AA

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SINAMICS G120 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Cu240s pnCu240s pn-fCu240eCu240sCu240s dpCu240s dp-f

Table of Contents

Save PDF