For infrared/radio transmission

Advertisement

Interface
Installation instructions
Type
English
IF59-A2
1
For Infrared Transmission
For Radio Transmission

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IF59-A2 and is the answer not in the manual?

Questions and answers

Summary of Contents for BLUM IF59-A2

  • Page 1 Interface For Infrared Transmission For Radio Transmission Installation instructions English Type IF59-A2...
  • Page 2 The language version of the manufacturer (DE/EN) is decisive for the technical content. Subject to technical change without notice. Original operating instructions © 2007 - 2018 by Blum-Novotest GmbH All brands stated in this document are the property of the respective brand owners. Article number of this documentation: 180168_EN...
  • Page 3: Table Of Contents

    3.2 IF59-A2 at PLC........
  • Page 4 10. Service............46 © by Blum-Novotest...
  • Page 5: Introduction

    Please read and observe the notes included in these instructions. Subject to technical change without any notice. Keys Information on secondary literature Additional advice LED shines LED flashes Green Blue Orange Violet White © by Blum-Novotest V3A | 08/2018...
  • Page 6: Further Applicable Documents

    1 2 3 freely selectable 1 2 3 Default condition of standard version 1 2 3 Further applicable documents Control-specific connection diagrams These are available at Blum-Novotest. Installation instructions IF59-30 Abbreviations operating voltage Solid State Relais Switch V3A | 08/2018...
  • Page 7: System Overview

    System overview 2. System overview Complete system The interface IF59-A2 is compatible for BLUM measuring devices with infrared and ra- dio transmission. The receiver enables wireless communication between the measuring devices and the NC control. Data transfer to the NC control via IF59-A2 interface.
  • Page 8 System overview TC60/61/62/63 BG60/61 RC66 TC63/TC64 Z-Nano Z-Nano RC IF59 - A2 Fig. 2-2 V3A | 08/2018 © by Blum-Novotest...
  • Page 9: Dimensions

    1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 39,5 Fig. 2-3 (1) DIP switch 1 (4) Button SET (2) DIP switch 2 (5) LED SET (3) Coding switch © by Blum-Novotest V3A | 08/2018...
  • Page 10: Technical Data

    4 x 10 mA Outputs 4 x 50 mA Push-pull 1 x 50 mA Solid State Relay (SSR) Interface RS232 Storage temperature -20 °C ... +70 °C Operating temperature +5 °C ... +50 °C Tab. 2-1 V3A | 08/2018 © by Blum-Novotest...
  • Page 11: Electrical Connection

    Connect each individual wire to its own terminal. NOTICE Damage by improper installation of cables and hoses  When mounting cables and hoses, please provide sufficient strain relief.  Please note the minimum binding radius of cables and hoses. © by Blum-Novotest V3A | 08/2018...
  • Page 12: Overview

    1 2 3 4 5 6 7 8 9 10 IF59-2 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 IC56 RC66 NC/PLC/PC IC57 Fig. 3-1 V3A | 08/2018 © by Blum-Novotest...
  • Page 13 Electrical connection NOTICE Measuring system malfunctioning and damage possible as a result of faulty earthing.  Use the enclosed BLUM accessory set!  Earth the measuring system as per the installation instructions for the accessory set! NOTICE Material damages caused by wrong wiring of the interfaces at the machine control The electrical connections, mentioned in this instruction, are exemplary and may vary depending on the machine control.
  • Page 14: If59-A2 At Plc

    Electrical connection IF59-A2 at PLC 3.2.1 Switch-on / Off Level-Controlled M(Mode TC) BATTERY ERROR STATUS STATUS 1 2 3 4 5 6 7 8 9 1011 1213 1415 1 2 3 4 5 6 7 8 9 10 IF59 1 2 3 Fig.
  • Page 15 IR: Probe switch-off method: Optical off (flash) Radio: Automatic pairing via input AUX is not possible. Switch-on/-off via M-function START = 24 V Start release M(Mode TC) = 1 Mode TC M(Mode TC) = 0 Mode standby © by Blum-Novotest V3A | 08/2018...
  • Page 16 STATUS STATUS 1 2 3 4 5 6 7 8 9 1011 1213 1415 1 2 3 4 5 6 7 8 9 10 IF59 1 2 3 Fig. 3-3 Switch-on / off Level-Controlled V3A | 08/2018 © by Blum-Novotest...
  • Page 17 IR: Probe switch-off method: Optical off (flash) Radio: Automatic pairing via input AUX is not possible. Switch-on/-off via M-function START = 24 V Start release M(Mode DUO) = 1 Mode DUO M(Mode DUO) = 0 Mode standby © by Blum-Novotest V3A | 08/2018...
  • Page 18 1 2 3 4 5 6 7 8 9 1011 1213 1415 1 2 3 4 5 6 7 8 9 10 IF59 1 2 3 Fig. 3-4 Switch-on / Off Level-Controlled, 2 M-Codes V3A | 08/2018 © by Blum-Novotest...
  • Page 19 M(Mode DUO) = 0 M(Mode TC) = 0 Mode standby M(Mode DUO) = 0 Measurement DUO: M(Mode TC) = 0 M(Mode DUO) = 1 Mode DUO M(Mode DUO) = 0 Mode standby M(Mode TC) = 0 © by Blum-Novotest V3A | 08/2018...
  • Page 20: Switch-On / -Off Impulse-Controlled

    1 2 3 4 5 6 7 8 9 1011 1213 1415 1 2 3 4 5 6 7 8 9 10 IF59 1 2 3 Fig. 3-5 Switch-On / -Off Impulse-Controlled IR: Probe switch-off method: Optical off (flash) V3A | 08/2018 © by Blum-Novotest...
  • Page 21: Switch-On Autoflash - Switch-Off Timeout

    1 2 3 4 5 6 7 8 9 1011 1213 1415 1 2 3 4 5 6 7 8 9 10 IF59 1 2 3 Fig. 3-6 Switch-ON Autoflash / Switch-Off Timeout OFF Not available for radio transmission IR: Probe switch-off method: Timeout Off © by Blum-Novotest V3A | 08/2018...
  • Page 22: Electrical Connection If59-A2 And Laser System / Z-Nano On One Mea

    Electrical connection Electrical connection IF59-A2 and laser system / Z-Nano on one mea- suring input STATUS (YE) STATUS (GY) 1 2 3 1 2 3 DYNAMIC (GN) Y *.* EN0, EN1, EN2 1 2 3 4 5 6 7 8 9 1011 1213 1415...
  • Page 23: Configuration

    A new dip-switch position is confirmed on the LED SET with a flashing sequence (red – green – blue). 1 2 3 4 5 6 7 8 9 10 1 2 3 4 4 5 6 7 8 9 10 1 2 3 © by Blum-Novotest V3A | 08/2018...
  • Page 24: Dip Switch 1

    Battery low: “Low” signal (falling edge) ERROR: Error Error: “High” signal (rising edge) OFF * ERROR: Error: “Low” signal (falling edge) Status2 N/C: Status2 OFF * Status2 N/O: * status of delivery ** not valid for radio transmission V3A | 08/2018 © by Blum-Novotest...
  • Page 25 Here, the signals STATUS and ERROR must be con- trolled. OFF * Error causes "status deflected" "Battery low" activates output signal ERROR Error OFF * "Battery low" doesn’t influence output signal ERROR * status of delivery ** not valid for radio transmission © by Blum-Novotest V3A | 08/2018...
  • Page 26 If mode DUO is not selected, the receiver switches to standby automatically. ON ** Transmitter power for activation signal (flash) 50% Activation OFF * Transmitter power for activation signal (flash) 100% * status of delivery ** not valid for radio transmission V3A | 08/2018 © by Blum-Novotest...
  • Page 27: Dip Switch 2

    Input AUX = enabled Input AUX OFF * Input AUX = disabled Input AUX: Measurement with level change high-low Condition: IF59-A2 in Mode Standby Input AUX OFF * Input AUX: Measurement with level change low-high Condition: IF59-A2 in Mode Standby...
  • Page 28: Electrical Connection

    24 V / 50 mA Stat1 Output STATUS1 24 V / 50 mA Error Output ERROR 24 V / 50 mA Stat2 Output STATUS2 Solid State Relay (SSR) Input AUX 10 ... 30 V / 10 mA Mass V3A | 08/2018 © by Blum-Novotest...
  • Page 29 IC56 / RC66 / IC57-A1 / IC57-A2 / IC57-A3 Adapter cable 142810 / 142812 IC57-A3 Adapter cable 142808 / 142809 Connection Designation Data T x D receiver data V24 interface R x D transmitter data V24 interface Mass Tab. 4-1 © by Blum-Novotest V3A | 08/2018...
  • Page 30: Setup Radio System

    Setup radio system 5. Setup radio system In order that a radio measuring system can work together with the IF59-A2, it must be assigned to an operating mode in which it can be activated. This process is called "pair- ing".
  • Page 31 Probes with DIGILOG or RG-function can be used in the operating mode TC or in the operating mode DIGILOG. For the pairing procedure, please use the coding switch position 1, 2, 3. Tab. 5-1 During operating mode DIGILOG, the LED SET is shining blue. © by Blum-Novotest V3A | 08/2018...
  • Page 32: Pairing Procedure Via Set-Key (Manual Pairing)

     Magnetic pin 1. Turn coding switch to requested probe assignment. 2. Actuate SET-key on IF59-A2, until LED SET flashes white. 1 2 3 4 5 6 7 8 9 10 1 2 3 4 4 5 6 7 8 9 10 1 2 3 3.
  • Page 33 Setup radio system off MODE 4. Turn back coding switch on IF59-A2, position "0". Actuate SET-key on IF59-A2. 1 2 3 4 5 6 7 8 9 10 1 2 3 4 4 5 6 7 8 9 10 1 2 3...
  • Page 34 Pairing successful 4 5 6 7 8 9 10 1 2 3 Failure pairing Pairing runs 1b + 1c Pairing successful 1b + 1c Failure pairing Pairing runs Pairing successful Failure pairing MODE Tab. 5-2 V3A | 08/2018 © by Blum-Novotest...
  • Page 35: Pairing Procedure Via M-Function (Automatic Pairing)

    Setup radio system Pairing procedure via M-function (automatic pairing) Probe Z-Nano cannot be operated via the AUX-input as the AUX-input is used for pairing.  IF59-A2, DIP switch 2: 1 2 3  Touch probe: Standby-Mode IF59-A2: Standby-Mode RC66:connected with IF59-A2 ...
  • Page 36 M(Mode TC) M(Mode DUO) M(Start) M(Mode BG) M(Mode TWIN) Ba ery Error 24 V Status Status 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 IF59-2 Fig. 5-1 V3A | 08/2018 © by Blum-Novotest...
  • Page 37 3. Signal Stat1 = high:End of pairing off MODE Signal Error = high:Pairing successful Signal Error = low:Pairing failed 4. To terminate the action, reset signals TC / DUO / BG / TWIN. 5. Reset signal AUX. © by Blum-Novotest V3A | 08/2018...
  • Page 38: Measuring Sequence

    (6) Error transmission interrupted (SW8=OFF, SW4=OFF) (2) Mode TC (7) Error rectified (3) Activate probe (8) Warning: Battery low (SW5=OFF) (M-Code) (4) Deflect stylus (9) Deactivate probe (M-Code) (5) Stylus initial position (10) Exchange probe / standby V3A | 08/2018 © by Blum-Novotest...
  • Page 39: Tc - Level Controlled - Sw8=On

    (6) Error transmission interrupted (SW8=ON, SW4=OFF) (2) Mode TC (7) Error rectified (3) Activate probe (M-Code) (8) Warning: Battery low (SW5=OFF) (4) Deflect stylus (9) Deactivate probe (M-Code) (5) Stylus initial position (10) Exchange probe / standby © by Blum-Novotest V3A | 08/2018...
  • Page 40: Tc - Impulse-Controlled

    (6) Error transmission interrupted (SW8=OFF, SW4=OFF) (2) Mode TC (7) Error rectified (3) Activate probe (M-Code) (8) Warning: Battery low (SW5=OFF) (4) Deflect stylus (9) Deactivate probe (M-Code) (5) Stylus initial position (10) Exchange probe / standby V3A | 08/2018 © by Blum-Novotest...
  • Page 41 M-function is repeated as long as the ERROR signal gives the message "probe system ready". Otherwise the probing system is not switched on with M46 but switched off! © by Blum-Novotest V3A | 08/2018...
  • Page 42: Tc - Switch-On Autoflash / Switch-Off Timeout

    (6) Error transmission interrupted (SW8=OFF, SW4=OFF) (2) Mode TC (7) Error rectified (3) Activate probe (Autoflash) (8) Warning: Battery low (SW5=OFF) (4) Deflect stylus (9) Deactivate probe (M-Code) (5) Stylus initial position (10) Exchange probe / standby V3A | 08/2018 © by Blum-Novotest...
  • Page 43: Troubleshooting

    LED SET flashes red The receiver is not identified. Check cable wiring. Connect the cable according to the wiring diagram. Execute voltage reset: Disconnect plug X1 for a short time and recon- nect again. © by Blum-Novotest V3A | 08/2018...
  • Page 44: Order Numbers

    Order numbers 8. Order numbers Use original parts and accessories by Blum-Novotest only. Interface IF59-A2 142821 V3A | 08/2018 © by Blum-Novotest...
  • Page 45: Ec Declaration Of Incorporation

    The relevant technical information is compiled acc. to annex VII part B and, where ap- propriate, we will send the information concerning the components to the different countries. The industrial property rights of Blum-Novotest GmbH will remain unaffect- Component name...
  • Page 46: Service

    Service 10.Service Headquarters: Worldwide: Blum-Novotest GmbH Kaufstr. 14 88287 Grünkraut, Germany Tel.:+49 751 6008-0 Fax:+49 751 6008-156 www.blum-novotest.com Vertrieb/Sales: sales@blum-novotest.com Service: service@blum-novotest.com Hotline: Vertrieb/Sales: Tel.:+49 751 6008-200 Tel.:+49 751 6008-202 Service: V3A | 08/2018 © by Blum-Novotest...
  • Page 48 www.blum-novotest.com...