  • Page 1: Table Of Contents

    WireCrafters Installation Instructions INCLUDED IN THIS MANUAL General Information Slide Door Receiver Panels & Posts Tunnel Door Adjustable panels Basic Ceiling TES-4 & JSPE Detail 2” x 2” Horizontal Ceiling Tube Hinge Door Hardware 2” x 4” Horizontal Ceiling Tube Hinge Door Inside Swing 2”...
  • Page 2: General Information

    1-800-626-1816 The following General Installation Instructions should be used as a guide for installing WireCrafters Style 840 Partitions. Because of the varying job site conditions, and infinite layout possibilities, there is no “recommended” way to install the product. Good common sense and proper safety precautions must be used during installation.
  • Page 3: Panels & Posts

    WireCrafters Panels and Posts Panels and Posts Installation Use a chalk line to outline the partition layout on the floor. a. Out to out dimensions shown on drawing are to face side of posts. b. Post base plates project 2-1/2” beyond outline of partition.
  • Page 4: Adjustable Panels

    WireCrafters Adjustable Panel Installation Adjustable Panel (AP) Installation Used to fill gaps of 1” to 11” in partition runs. 1. Place 3-1/4” spacer block under non-supported end of partition run. 2. Fit the AP panel in the gap between the end post (or building wall) and wire mesh panel.
  • Page 5: Tes-4 & Jspe Detail

    WireCrafters TES-4 & JSPE Details POST SPLICE INSTRUCTIONS Force the JSPE (A) into the bottom post (B) until it bottoms out on panel bolt (C). Force (D) until the top and bottom posts meet flush.
  • Page 6: Hinge Door Hardware

    WireCrafters Hinge Door Hardware Pack...
  • Page 7: Hinge Door Inside Swing

    WireCrafters Hinge Door Inside Swing Right Hand Shown INSTALLER NOTES: 1. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads. DO NOT USE IMPACT TYPE GUNS.
  • Page 8: Hinge Door Outside Swing

    WireCrafters Hinge Door Outside Swing Right Hand Shown INSTALLER NOTES: 1. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads. DO NOT USE IMPACT TYPE GUNS.
  • Page 9: Dutch Door

    WireCrafters Dutch Door Outside Swing Right Hand Shown INSTALLER NOTES: 1. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads. DO NOT USE IMPACT TYPE GUNS.
  • Page 10: Double Hinge Door

    WireCrafters Double Hinge Door INSTALLER NOTES 1. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads. DO NOT USE IMPACT TYPE GUNS. Securely clamp part in place before attaching with self drilling screws.
  • Page 11: Slide Door Hardware

    WireCrafters Slide Door Hardware Pack...
  • Page 12: Slide Door Outside

    WireCrafters Outside Slide Door INSTALLER NOTES 1. Doors wider than 5’ are made up of multiple door panels (see page 16), and use two pieces of track spliced at Splice Track Bracket (A). 2. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads.
  • Page 13 WireCrafters Outside Slide Door...
  • Page 14: Slide Door Inside

    WireCrafters Inside Slide Door INSTALLER NOTES 1. Doors wider than 5’ are made up of multiple door panels (see page 16), and use two pieces of track spliced at Track Bracket (A). 2. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads.
  • Page 15 WireCrafters Inside Slide Door...
  • Page 16: Slide Door Panel Assembly

    WireCrafters 6’ or Wider Slide Door Panel Assembly SLIDE DOOR PANEL ASSEMBLY 1. Attach door panel (A) to leaf panel(s) (B) with 3/8” x 1” bolts. a. 10’ wide doors have 4’ 2” wide door panel, 4’ wide leaf panel, and 2’ wide leaf panel.
  • Page 17: Slide Door Receiver

    WireCrafters Slide Door Receiver Note: Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece when installing self-drilling screws. DO NOT USE IMPACT TYPE GUNS. RECEIVER LOCATION : 1. Measure from floor to center of the installed slide door’s lock opening-...
  • Page 18: Tunnel Door

    WireCrafters Tunnel Door INSTALLER NOTES 1. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads. DO NOT USE IMPACT TYPE GUNS. Securely clamp part in place before attaching with self drilling screws.
  • Page 19: Basic Ceiling

    WireCrafters Basic Ceiling INSTALL SLOTTED ANGLE 1. Cut slotted angle 1/2” shorter than panel width. 2. Install slotted angle on the top panel with one leg up to the inside of the enclosure or wall using 3/8” x 1” bolts.
  • Page 20: 2" X 2" Horizontal Ceiling Tube

    WireCrafters 2” x 2” Horizontal Ceiling Tube 2” x 2” CEILING TUBE 1. Note overall layout of ceiling. 2. Identify location(s) of 2” x 2” horizontal ceiling tube(s) (A). 3. Using two self drilling screws, center and attach one 3/16” x 1-3/4” x 3”ceiling bracket (B) on posts(D) where horizontal ceiling tubes are to be installed.
  • Page 21: 2" X 4" Horizontal Ceiling Tube

    WireCrafters 2” x 4” Horizontal Ceiling Tube 2” X 4” CEILING TUBE Note location(s) of 2” x 4” horizontal ceiling tube(s) (A). Center and attach one 3/16” x 1-3/4” x 3” Angle Bracket (B) to the top 2” side of 2”...
  • Page 22: 2" X 6" Horizontal Ceiling Tube

    WireCrafters 2” x 6” Horizontal Ceiling Tube 2” X 6” CEILING TUBE 1. Note location(s) of 2” x 6” horizontal ceiling tube(s) (A). 2. Lift ceiling tube (A) so that holes in mounting plates match holes at top of partition wall post (D).
  • Page 23: Ceiling Tube Masonry Connections

    WireCrafters Ceiling Tube Masonry Connections...
  • Page 24: Physical Barrier

    WireCrafters Physical Barrier 6’-2” Height PHYSICAL BARRIER 6’ 2” HEIGHT PANEL & POST INSTALLATION Use a chalk line to outline the partition layout on the floor. a. Out to out dimensions shown on drawing are to face side of posts.
  • Page 25: Barrier Hinge Door Outside Swing

    WireCrafters Barrier Hinge Door Outside Swing Right Hand Shown INSTALLER NOTES: 1. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads. DO NOT USE IMPACT TYPE GUNS. Securely clamp part in place before attaching with self drilling screws.
  • Page 26: Barrier Hinge Door Inside Swing

    WireCrafters Barrier Hinge Door Inside Swing Right Hand Shown INSTALLER NOTES: 1. Component parts attach using self-drilling screws. Use variable speed screw gun with adjustable clutch or depth locating nose piece. Use care not to over tighten and strip threads. DO NOT USE IMPACT TYPE GUNS.
  • Page 27: Rack Back

    WireCrafters Rack Back® INSTALLER NOTES 1. Provided mounting hardware may not be appropriate for all types of rack. Installer may need to acquire additional or other type fasteners. 2. It is installer’s responsibility to securely install brackets and panels to rack structure.
  • Page 28: Rack Back® Hinge Door

    WireCrafters Rack Back® Hinge Door INSTALLER NOTES 1. Provided mounting hardware may not be appropriate for all types of rack. Installer may need to acquire additional or other type fasteners. Rack Back® Hinge Gates 1. Locate gate hinge brackets (brackets with pins attached) and machine bushings.
  • Page 29: Component Location Work Sheet

    NON-STOCK COMPONENT LOCATION WORK SHEET All locations are from floor to bottom of component Fill in blanks with appropriate Dimensions before starting calculations Sweep Space ________ Door Leaf Height ________ Center Line of Door ________ (Divide Door Leaf Height in Half) Center Line of Tongue Hole in Door Leaf ________ Bottom Door Leaf Height________ (Dutch Door Only) Top Door Leaf Height ________ (Dutch Door Only)
  • Page 30 WireCrafters 800-626-1816 Thanks for using WireCrafters woven wire partitions. Tool Cribs • Storage Lockers • Machine Guards • Mezzanine Rails • Pallet Rack Backs • Security Enclosures...
  • Page 31 WireCrafters We appreciate your business, and hope to work with you on future projects. A significant effort went into creating this instruction booklet and we are interested in your comments regarding it. Please answer the questions below, tear off this page, and fax it to us at 502-361-3857, or fold on the dotted lines, tape shut, and drop in the mail. We welcome your suggestions and observations.