The Command Access MLRK1-FAL17 is a field installable motorized latch-retraction kit for:
• MRLK1-FAL17 - Falcon 16 & 17 series devices
• MRLK1-FC37 - First Choice 36 & 37 series devices
B.
Kit Incl ud e s
1- Motor Mount w/MM4S
A.
1- 50944 Molex Pigtail
B.
1- 50030- 6' Lead w/ VD Connector
C.
2- 40306 Sets of finished phillips screws
D.
•
Input Voltage: 24VDC +/- 10%
•
Wire gauge: Minimum 18 gauge
•
Direct wire run - no relays or access control units in-between
power supply & module
Re com me nde d Power Suppli es:
All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory. If you
plan on using a non-Command power supply it must be a filtered & regulated linear power supply.
U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w . c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2
Field installable motorized latch-retraction kit for mlrk1-ts - town steel 1100 series devices, mlrk1-uscan - uscan2100 series devices, mlrk1-lsda2 - idn lsda 9200 series devices (7 pages)
Summary of Contents for Command access MLRK1 Series
Page 1
Re com me nde d Power Suppli es: All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory. If you plan on using a non-Command power supply it must be a filtered & regulated linear power supply.
Page 2
Technical Information GREEN CHANNEL 1 Ceiling Tile NORMALLY OPEN DRY CONTACT FROM ACCESS CONTROL SYSTEM NO VOLTAGE LOCKING HARDWARE Module Legend Standard Placement Optional Placement Setting PTS **Important Info** Make sure to set PTS before finishing installation MM4S SWITCHES Select your preferred torque mode (ships in standard torque). Press the Step 1 - STANDARD TORQUE device push pad to the desired setting.
Page 3
Installation Instructions Remove Dogging Assembly by removing (2) screws furthest to Remove (2) screws securing the push pad end caps on the the back end of the device. front & back, and then the push pad end caps. Place all to the side. if your device is equipped with a donut bumper on the back start by removing (2) screws to release the back activating bracket.
Page 4
Now with the donut bumper &/or dogging hook removed. We can Drop the attaching hook on the motor assembly onto the bottom pin install our motor kit by depressing the back activating bracket. of the activating bracket. Line up the motor’s mounting bracket screw holes with the existing screw holes from the dogging assembly on the exit device housing. Secure the motor assembly from the back of the device with (2) of the finished screws provided.
Page 5
Re-install top pins on both activating brackets and slide on the push pad making sure pins are in the proper channel. Re-install (2) screws securing the push pad 12. Set the “Push to Set Adjustment” following the steps below, end caps on the front & back. remembering to turn the Programming Switch to the off position when completed.
Need help?
Do you have a question about the MLRK1 Series and is the answer not in the manual?