English (GB) Service instructions Original service instructions 1. Type identification These service instructions cover the basic pump version (A) and 1.1 Nameplate the drainage-back-to-tank pump version (D) of MTR, MTRE 1s, 1, 3, 5, 8. Note that some parts of the pump were replaced in August 2015 (week 32).
1.2 Type key Example 32 (s) Pump type Pump with integrated frequency control Rated flow rate [m All impellers with reduced diameter (only MTR 1s) Number of chambers. See fig. 2. Number of impellers. See fig. 2. Number of impellers with reduced diameter Pump version Basic version Oversize motor...
1.3 Code for shaft seal The code for shaft seal always consists of four letters: Example Principal Grundfos type designation for shaft seal Material, rotating seal face Material, stationary seat Material, secondary seal The following codes are used: Pos. Code...
3. Service tools 3.1 Special tools Pos. Designation For pos. Description Part number Shaft holder for assembly SV0040 Box spanner for shaft seal SV2007 Puller for neck ring SV0239 Punch for removing the shaft SV0238 Mounting ring SV0872 Mounting band SV0871 3.2 Torque tools Pos.
4. Dismantling and assembling pump version A Example of type key for pump version A (basic Fig. 3 version) Position numbers Position numbers of parts (digits) refer to exploded views, sectional drawings and parts lists; position numbers of tools (letters) refer to section 3.
4.2.2 Fitting the shaft seal, coupling and motor 4.3 Checking and replacing impellers or wear rings and neck rings 1. Assemble the chamber stack. See section 4.2.1 Assembling the chamber stack. Impellers or wear rings 2. If necessary, clean and smooth the shaft end using the holder 1.
5. Dismantling and assembling pump version D Pump head 18. Prise the stationary shaft seal part out of the pump head, using a nylon punch or similar tool. Remove the lip seal (183). Do not expose the stationary shaft seal part to blows or Example of type key for pump version D (drainage knocks.
18. Fit the motor and turn it to the required terminal box position. 5.3 Checking and replacing impellers or wear rings Lubricate the screws (28). Fit the screws and tighten and neck rings diagonally to the torque stated. See section 2.
6. Order of assembly for chambers and impellers 6.1 Overview of chambers for MTR, MTRE 1s, 1, 3, 5 (before 1532, production year and week) The production year and week is printed on the nameplate. See section Nameplate.
6.2 Overview of chambers for MTR, MTRE 1s, 1, 3, 5 (after 1532, production year and week) The production year and week is printed on the nameplate. See section Nameplate.