telsiu altas START-S3XL Instruction Manual

telsiu altas START-S3XL Instruction Manual

Radio receiver

Advertisement

• Universal control unit for 1 sliding gate or up-and-over door.
• Motor, 3levels of slow down. Inputs: start-timer- clock, photocell during closing,
limit switch during opening and closing, partial opening, stop.
• Time acquisition "real-time".
100%
START-S3XL
ITAL Y
230 Vac
230 Vac
Lamp
MOT
common
MOT
close
MOT open
Com 1 and - Antenna
Com 2 / - 12/24Vdc
+ 12 Vdc
STOP
FOTO
LSO
LSC
Pedestrian
24 Vac
+ 24 Vac/dc
Light-Fototest
Light-Fototest
Mechanical edge - NC
Mechanical edge - NC
-1-
-2-
-3-
-4-
-5-
-6-
-7-
-8-
-9-
-10-
-11-
-12-
-13-
-14-
-15-
-16-
-17-
-18-
-19-
-20-
-21-
-22-
-23-
CL
C
N.C.
N.C.
N.C.
N.A.
If the input SAFETY-EDGE
is not used, make a link (22-23)
*
Connect this point to the terminal board no.
21 for the photo-test, otherwise connect it to
the terminal board no. 19
Radio receiver
Lamp or courtesy light
230 Vac
COM
OP
M
Photocells working
*
N.A.
in closing

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the START-S3XL and is the answer not in the manual?

Questions and answers

Summary of Contents for telsiu altas START-S3XL

  • Page 1 • Universal control unit for 1 sliding gate or up-and-over door. • Motor, 3levels of slow down. Inputs: start-timer- clock, photocell during closing, limit switch during opening and closing, partial opening, stop. • Time acquisition “real-time”. 100% START-S3XL ITAL Y Radio receiver 230 Vac 230 Vac...
  • Page 2 START-S3XL Technical Manual Index Foreword Par. Description Pag. This manual provides all the specifi c information you Introduction need to familiarize yourself with and correctly operate Product description your unit. Read it very carefully when you purchase the Field of application...
  • Page 3: Safety Precautions

    Every programming and/or every maintenance service should be done by qualifi ed technicians. Field of application The START-S3XL electronic control unit is used to control the movement of entrances, swinging gateways, rolling gates and automatic doors. It can be connected to a hydraulic or electromechanical actuator equipped with an asynchronous, single-phase motor operating at a voltage of 230 Vac.
  • Page 4: Diagram Of The Control Unit And Electrical Connections

    START-S3XL Technical Manual Installation Diagram of the control unit and electrical connections 1  2 control unit power supply 230Vac 3  7 power supply for motor and for fl asher 230Vac power supply voltage to accessories and to 8  19 service and safety inputs “clean”...
  • Page 5: Table Of Contents

    START-S3XL Technical Manual Description of the electrical connection 230 Vac Electrical power supply 230 Vac 50 Hz 230 Vac Electrical power supply 230 Vac 50 Hz Output for fl ashing or courtesy light 230 Vac, maximum power rating of Lamp the lamp 100W.
  • Page 6: 230 Vac

    START-S3XL Technical Manual Connection of the FLASHING LIGHT 230 Vac DIP 4 - ON 20 21 Flashing light complete without intermittence circuit board Flashing light complete with intermittence circuit board If you plan to use the photocells test, or a 24V light, this connection cannot be used.
  • Page 7: Connection Of The Stop/Alt Control Devices

    START-S3XL Technical Manual Connection of the STOP/ALT control devices Connection of the STOP control Connection of the ALT control Push-button: stops and temporarily prevents all Stops the automation and activates an inversion of control unit function until it is pressed again.
  • Page 8 START-S3XL Technical Manual 24 Vac 2.10 Connection of the photocell Without TEST With TEST 9 10 11 12 13 14 15 16 17 18 19 20 21 9 10 11 12 13 14 15 16 17 18 19 24 Vac...
  • Page 9: Stop

    START-S3XL Technical Manual 2.12 Connect the 3 WIRES PHOTO-BEAM Bring JUMPER AC/DC 9 10 11 12 13 14 15 16 17 18 19 as shown in the picture Voltage: 24 Vdc POWER SUPPLY Maximum current: 300 mA RX PHOTOCELL Photocell receiver.
  • Page 10 START-S3XL Technical Manual Operating logic for DIP 2-ON When open and in pause mode the unit does not accept commands; condominium 3-OFF it closes automatically at the end of the pause time. semi Each command is followed by the open-stop-close-stop-open,...
  • Page 11 START-S3XL Technical Manual Management of REMOTE CONTROL To manage remote controls, the electronic circuit board must have a wireless module. The electronic circuit board can handle several types of code, the fi rst remote control learned determines the type and, as a result, it is not possible to learn remote controls with codes that differ from that of the fi...
  • Page 12: Antenna

    START-S3XL Technical Manual Remote control LEARNING The remote control code can only be learned when the automation is CLOSED During the program, to avoid any interferences, we recommend to disconnect the antenna for a while from the terminal board no. 8-9.
  • Page 13: Pedestrian

    START-S3XL Technical Manual Learning “START” OPENING COMMAND times Turn off the circuit board The automation Set switch DIP 1 to ON is in the CLOSED Power the control unit; the two green lights fl ash 4 times led L1 position.
  • Page 14 START-S3XL Technical Manual Times learning with the “PEDESTRIAN” COMMAND The PEDESTRIAN command is used to open the automation only partially to allow people and small vehicles to pass through without having to open the gate completely. When opening is performed with this command, the automation decelerates only when it is closing and following the setting previously acquired in the START command programming.
  • Page 15 START-S3XL Technical Manual Increasing the PAUSE time The pause time can be increased without having to repeat the times learning operation. While the automation is in pause mode, each time the push-button P is pressed the pause time is increased by 5 seconds. The level can be increased four times.
  • Page 16: Start

    START-S3XL Technical Manual Declaration of CE conformity ....................(according to EC Directive 2006/42, Attachment II, part 1, ses. A) ..........The undersigned Ernestino Bandera, Administrator ..........DECLARES THAT: ..........Company: EB TECHNOLOGY SRL ..........Address: Corso Sempione 172/5 21052 Busto Arsizio VA Italy ..........

Table of Contents