Siemens 7XV5655-0BB00 Manual page 31

Modem for transmission of serial data or protocols from devices with an rs232, rs485 or fo interface via ethernet
Hide thumbs Also See for 7XV5655-0BB00:
Table of Contents

Advertisement

Using "HyperTerminal" via the Serial Interface of a PC
This terminal program is supplied as a standard feature of the operating system
®
WINDOWS
XP.
Start HyperTerminal under:
"Start
Programs
Note: The Serial Modem can only be set via the serial interface in the currently set
baudrate and data format. If these settings were changed, the connection settings in
HyperTerminal would have to be adjusted.
It is advisable to note down these settings to avoid any problems accessing the
modem later.
SIEMENS AG
Accessories
Communications
Page 31 of 79
HyperTerminal"
Enter a name for the new
connection, e.g. 9600 8N1.
The connection can be saved
on exiting.
Assign a PC interface to the
connection,
e.g. COM1.
For a new Serial Modem, select the
settings
bits per second,
9600
data bits,
8
for parity,
none
stop bit and
1
for flow control
none
Continue with
OK
Manual 7XV5655-0BB00