Table of contents Table of contents Safety instructions and warnings ..........5 General ................... 5 1.1.1 Definitions ..................5 1.1.2 Symbol explanation ................. 6 Intended use ................... 7 Foreseeable misuse ................ 8 Beauty system safety information ........... 8 1.4.1 Collagen device ................8 1.4.2 Important notes ................
Page 4
Technical data ................60 Power, connection rating and noise level ........60 Dimensions ..................61 Lamp sets ..................62 5.3.1 Ergoline Beauty Angel 7200 ............62 Spare parts and accessories ............63 Appendix ..................64 JK timer controls ................64 Index ..................... 65...
Safety instructions and warnings Safety instructions and warnings To ensure safe operation of the device, it is necessary to read the following safety instructions and warnings carefully and comply with them. The safety instructions summarized here are repeated in the corresponding chapters, where necessary.
Safety instructions and warnings 1.1.2 Symbol explanation The following types of safety notices are employed in these operating instruc- tions: DANGER! Type and source of hazard This safety notice indicates the existence of a direct danger to body and life. DANGER! Type and source of hazard This safety notice warns of dangers to body and life which...
Safety instructions and warnings Intended use This device provides cosmetic stimulation of the skin with red light (photo-bio- stimulation). Further information can be found on pages 27 and 28. This device is intended only for commercial use and not for private use. Some people are not permitted to use the device, see page 8.
Safety instructions and warnings Foreseeable misuse The following uses of the device are explicitly prohibited: The device is only to be used by one person at a time. People with a body weight of more than (150 kg) kg may not use the ...
Safety instructions and warnings 1.4.2 Important notes An application is not recommended in the following circumstances: If you have utilized an oxygen facial pack in the last 24 hours, If your facial skin has been electronically tightened in the last 24 hours, ...
Page 10
Safety instructions and warnings Acute hernia / intervertebral disc diseases / spondylolysis Rheumatoid arthritis Arthritic or arthropathic conditions (joint diseases) People with recently implanted intrauterine devices (contraceptive coils), metal pins, screws or plates are also only to use the device after consultation with their doctor.
Safety instructions and warnings Application times NOTE: The vibration programmes each run for 10 minutes and can be utilized simultaneously either with or independently of the light application. AGEsmart AGEsmart application – Treatment recommendations Applications PROTECT VITALIZE RENEW per week Light Intensive Light...
Safety instructions and warnings Safety instructions and warnings 1.6.1 Operator's obligations As the operator you are responsible for providing clear operating, cleaning and maintenance instructions and ensuring the intended use and the proper operation of the device by means of training and instruction for the personnel. Your operating instructions must enable the safe use and safe operation of the device and take into account the characteristics and expertise of your company and also the national work safety and environmental protection...
Page 13
Do not set up and operate the device on the transport pallet! Data regarding the air supply and ventilation planning is available in the plan- ning manual (www.ergoline.de, available in English and German). You can also obtain this data from your dealership or the customer service department (see page 2).
Page 14
Safety instructions and warnings Setup location WARNING! Salty air! Contaminated air! Device damage due to corrosion of the housing and electri- cal components. – Do not install the device at swimming pools. – Do not operate the device in locations with aggressive environmental conditions (e.g.
Safety instructions and warnings 1.6.5 Commissioning DANGER! Damaged mains power cable! Danger to persons through electric shock or burns. – Only the manufacturer or specialist companies are permitted to replace the mains power cable. Initial commissioning will be undertaken by the manufacturer's own service personnel or by an authorized service company.
Safety instructions and warnings 1.6.7 Decommissioning The device must be disconnected from the power supply in order to tempo- rarily or permanently decommission it. You must abide by the legal disposal requirements when permanently de- commissioning the device. 1.6.8 Storage Store the devices in a dry location with a stable temperature.
Safety instructions and warnings The components and devices are labelled with the following symbol: The device will, if requested, be properly disposed of by the JK Corporate Group. This service is available free of charge. Your partner agency or dealer will be happy to advise.
Safety instructions and warnings Further details can be found in the information brochure 'Audio Guide' availa- ble on the Internet at http://www.jk-globalservice.de . NOTE: Pre-recorded SD cards which are delivered as accessories for a JK audio system are also subject to payment obligation for commercial usage.
Safety instructions and warnings Signs and stickers on the device Danger area warning signs and important information about components are attached to the device. The signs shown below are examples. Ensure that the warning signs are always clearly recognisable and legible. Any missing warn- ing signs or stickers must be replaced.
Page 20
Safety instructions and warnings 2: Warning sticker (1511942-..) The sticker is located on the lamp covering on the right side section. This sticker also includes the language form 1512793-.. (see accessories Technical Documentation). 3: Sticker EMERGENCY OFF (1018687-..) 18465 / 1 This sticker also includes the language form 1018688-..
Page 21
Safety instructions and warnings 5: 'No export USA/Canada' sticker (84829-..) 6: Lamp set sticker XXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX XXX XXXXXXX XXXXXXX 19633 / 0 The sticker is located on the lamp covering on the left side section. 01/2020 1024357-00 Operating instructions – 21/68...
Page 22
Safety instructions and warnings 7: Sticker component control EU 1510515-.. The sticker is located on the cover of the control box. 22/68...
Safety instructions and warnings Warranty On behalf of customers who have purchased a Beauty Angel device for pri- vate or commercial utilisation from one of the JK-International GmbH sales partners, JK-International GmbH accepts liability for any defects on the device that arise in accordance with the following regulations;...
Description Functional description Beauty Device The application with red light (photo-bio-stimulation) promotes the formation of collagen and elastin. The short-term effect shows itself as a firmer and closer skin feeling and a more vital facial colouration. This is the result of oxygen enrichment and an increased level of ATP (adenosine triphosphate, the molecule for energy transfer in the metabolic system).
Description Description of the treatment programmes AGEsmart application RENEW AGEsmart application VITALIZE AGEsmart application PROTECT Suitable for more mature users in Suitable for mature users who Ideal for younger users of 18 years order to alleviate wrinkles and ac- wish to refresh their skin and and over for refining their com- tively combat skin aging counteract the initial signs of ag-...
Description AGEsmart and VibraShape Thanks to whole body vibration Ergoline Beauty Angel 7200 not only offers an innovative light treatment but also a healthy training effect. This is made pos- sible by a vibration plate integrated into the standing surface which activates the entire musculature through its vibration.
Operation Operation User safety information DANGER! Danger of hearing damage! Using earphones or headphones at high volume can result in permanent hearing damage. – Do not set the volume too high. Collagen device NOTE: Extending the specified application times cannot place ex- cessive demands on the skin due to the emitted light.
Operation Application tips Beauty Angel device Stand up straight and in the center of the device during the application. Bend knees slightly. Use overhead straps for support and to increase muscle tension. DANGER! Risk of crushing! Parts of your body could get into the gaps between base plate and vibration plate.
Page 32
Operation Vibra Shape DANGER! Risk of injury! The vibration function is not suitable for all users. – Please observe the contra-indications on page 9. NOTE: Each programme starts with a warm-up phase and ends with a cooling-down phase. A vibration programme normally lasts for 10 minutes.
Operation 3.4.1 Navigation The Control Center enables comfortable access to special functions. Acknowledge selection. This button's availability is displayed on the operating pan- el, depending on the function that has been selected. Acknowledge selection. This button's availability is displayed on the operating pan- el, depending on the function that has been selected.
Operation Functions Pictogram selection / Navigation Description / Display Information key sequence START/STOP The application time continues to run if the Switches the Beauty Angel Beauty Angel lamps are switched off dur- lamps on / off during the ing the application. application.
Page 36
Operation Pictogram selection / Navigation Description / Display Information key sequence EMERGENCY OFF In standby, the EMERGENCY OFF button does not have any function. If the EMERGENCY OFF button is pressed, the device shuts down except for the control element. In this state, the dis- play indicates that the EMERGENCY OFF button has been pressed.
Operation Start – Close the door. – Press the START/STOP button. Upon starting the following functions are switched on: Beauty Angel lamps Body cooling Audio system (optional) Voice Guide (optional) 01/2020 1024357-00 Operating instructions – 37/68...
Operation AUX (music) DANGER! Danger of hearing damage! Listening to music at a high volume can result in permanent hearing damage. – Do not set the volume too high. WARNING! The heat might damage your MP3 player or Smartphone! – Do not place the unit directly in the radiation area.
Cleaning and maintenance Cleaning and maintenance Safety instructions when undertaking cleaning or maintenance work DANGER! Electricity throughout entire device! Personnel danger due to electric shock or electric burns. – Before beginning work, disconnect all of the power connections from mains voltage. –...
Cleaning and maintenance Faults Error codes are output to the display to simplify troubleshooting: If a fault occurs, the error code flashes on the display. If several errors occur, the error messages are displayed alternately. Error elimination is acknowledged by pressing the START/STOP-button. ...
Cleaning and maintenance 4.3.1 Cleaning the surfaces Acrylic glass surfaces WARNING! Do not rub with a dry cloth – danger of scratching! Failure to comply invalidates any warranty claims. – For the fast, hygienic and proper cleaning of acrylic glass surfaces, use specially developed cleaning agents.
Cleaning and maintenance Cleaning plan Component Interval Activity See page Entry area Clean and disinfect Foot mat (silicone) Clean and disinfect Control panel Clean and disinfect Handles Clean and disinfect Door handles (outside / inside) Clean and disinfect Protective goggles Clean and disinfect AUX cable Clean and disinfect...
Cleaning and maintenance Maintenance Maintenance and care play a major role in deciding whether the device meets the requirements placed on it in a satisfactory manner. Compliance with the specified maintenance intervals and the careful conducting of the mainte- nance and care work are therefore absolutely necessary. The current operating hours of maintenance parts can be called up in service mode (see 'Professional Setup Manager'), order no.
Page 44
Cleaning and maintenance Component Interval Activity page Low pressure lamps, Replace rear door Low pressure lamps, Replace side walls Low pressure lamps, Replace front doors Acrylic panels, Inspect and replace as necessary rear wall Acrylic panels, side Inspect and replace as necessary walls Acrylic panels, doors Inspect and replace as necessary...
Page 45
Cleaning and maintenance Component Interval Activity page Acrylic panels, Replace side walls Acrylic panels, Replace front doors Filter Replace Filter mats Replace Foot mat (silicone) Inspect and replace as necessary AROMA canister Inspect and replace as necessary 01/2020 1024357-00 Operating instructions – 45/68...
Page 46
Cleaning and maintenance Maintenance performed by authorized, trained and qualified staff WARNING! Danger to persons from maintenance work that has not been carried out! If maintenance work is not carried out, it can lead to material damage or personal injuries! –...
Cleaning and maintenance Instructions for replacing the lamps DANGER! Danger of burns from hot lamps and surfaces! Finger and hands may get burned when replacing lamps. – Before carrying out maintenance work, wait until the device has cooled down sufficiently. Beauty Angel lamps Never replace with UV lamps of any type! ...
Cleaning and maintenance 4.8.1 Low pressure lamps DANGER! Danger of burns from hot lamps and surfaces! Finger and hands may get burned when replacing lamps. – Before carrying out maintenance work, wait until the device has cooled down sufficiently. Replace faulty UV low pressure lamps immediately. ...
Cleaning and maintenance Cleaning or replacing lamps in the doors WARNING! Acrylic glass panels unusable due to soiling! Soiling on the panels is burned in by the hot lamps and results in the long term in unserviceable panels. – Remove fingerprints and other soiling carefully. NOTE: There is a risk of damage being caused to the acrylic glass panels and the operating unit and air ducts!
Page 50
Cleaning and maintenance – Unscrew the screws of the strip. – Fold down the strip. – Remove the acrylic glass panel and carefully lay it aside. Changing the lamps: see page 47. 50/68...
Page 51
Cleaning and maintenance – Remove the magnetic cover. – Pull the lamps out downwards in order to remove them. The assembly is the same process in reverse order. During assembling, observe: – Insert the panel carefully into the rear guide. –...
Page 52
Cleaning and maintenance – Close the rear wall against slight resistance. – Unscrew the screw to lock the door. Front doors – Unscrew the screws. – Fold the strip away. – Remove the acrylic glass panel and carefully lay it aside. Changing the lamps: see page 47.
Page 53
Cleaning and maintenance – Remove the lamp cover. – Pull the lamps out downwards in order to remove them. The assembly is the same process in reverse order. During assembling, observe: – Insert the panel carefully into the rear guide. 01/2020 1024357-00 Operating instructions –...
Cleaning and maintenance 4.10 Cleaning or replacing lamps on the side walls WARNING! Acrylic glass panels unusable due to soiling! Soiling on the panels is burned in by the hot lamps and results in the long term in unserviceable panels. –...
Page 55
Cleaning and maintenance – Remove the acrylic glass panel and carefully lay it aside. Changing the lamps: see page 47. – Remove the lamp cover. – Pull the lamps out downwards in order to remove them. 01/2020 1024357-00 Operating instructions – 55/68...
Cleaning and maintenance The assembly is the same process in reverse order. During assembling, observe: – Insert the panel carefully into the rear guide. 4.11 Cleaning the filters DANGER! Sharp fan blades! Risk of cuts from the edges when fans are exposed. –...
Cleaning and maintenance – Cleaning the filters when moist or dry. Dry cleaning: Vacuum cleaner (depending on the degree of soiling) Moist cleaning: Use water and detergent or put in a dish-washer WARNING! The device may be damaged by moisture! The cleaned filters must be dry before they are replaced.
Cleaning and maintenance – Dry or moist clean the filter mats or replace with new ones. Dry cleaning: Vacuum cleaner (depending on the degree of soiling) Moist cleaning: Water and detergent – Do not clean in the dish-washer! WARNING! The device may be damaged by moisture! The cleaned filters must be dry before they are replaced.
Page 59
Cleaning and maintenance – Remove the VITAL scent can. – Write the current date on the rear of the new scent can. – Remove the lid from the canister. – Insert the new scent can. – Refit the filter. 01/2020 1024357-00 Operating instructions –...
Technical data Technical data Power, connection rating and noise level Ergoline Beauty Angel 7200 Power consumption rating: 6000 W Rated frequency: 50 Hz Rated voltage: 400-415 V 3N~ 230-240 V ~3 Rated fuses: 3 x 16 A (inactive) 3 x 20 A (inactive) Connecting line: H05VV-F 5G 2,5 mm²...
Technical data Dimensions BK = 2130 mm B4 = 580 mm BK1 = 345 mm B8 = 1440 mm BK2 = 345 mm T = 1442 mm TK = 2150 mm T1 = 1469 mm TK1 = 631 mm T3 = 770 mm TK2 = 150 mm H = 2308 mm B = 1242 mm...
Danger of burns from hot lamps and surfaces! Finger and hands may get burned when replacing lamps. – Before carrying out maintenance work, wait until the device has cooled down sufficiently. 5.3.1 Ergoline Beauty Angel 7200 Lamp set Number Description Length Power Control Order-no.
Appendix Appendix JK timer controls The following coin modules/time control systems can be utilized with the Er- goline Beauty Angel 7200 series devices. MCS III plus Order no.: 500000456 04144 / 0 Studiopilot Order no.: 34009900 64/68...