Oceanic OCS45 Assembly And Operating Manual
Oceanic OCS45 Assembly And Operating Manual

Oceanic OCS45 Assembly And Operating Manual

Sauna controller
Hide thumbs Also See for OCS45:

Advertisement

Quick Links

S a u n a & S t e a m
STAUNA CONTROLLER
Assembly and operating manual
PRODUCT IMAGE
Oceanic Ltd, Pountney Street, Wolverhampton, WV2 4HX
Phone: 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OCS45 and is the answer not in the manual?

Questions and answers

Summary of Contents for Oceanic OCS45

  • Page 1 S a u n a & S t e a m STAUNA CONTROLLER Assembly and operating manual PRODUCT IMAGE Oceanic Ltd, Pountney Street, Wolverhampton, WV2 4HX Phone: 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 2: Table Of Contents

    Guarantee ..........15 Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 3: Introduction

    S a u n a & S t e a m Stauna Manual Introduction Thank you for choosing to buy our Oceanic Stauna Controller please take the time to read these instructions before you begin as they contain important information about the installation and maintenance requirements.
  • Page 4 C - 40-50% humidity Max Temp 48 C - 50-60% humidity Sauna Caldarium Very High Heat - No Steam High Heat - Low Steam Max Temp 100 Max Temp 65 C - 30-40% humidity Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 5 5 core heat proof cable to sauna heater. Not Provided 6 core 12V cable to Control Pad. 4m Provided 4core signal cable to MSG. 2m Provided 3 core 1mm silicon cable to MSG. Not provided Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 6: General Setup Overview

    OC - ST Temperature Sensor 4 core 12v cable Lighting circuit - 240v (4m Supplied) Blue - 12 volts Switched from button on Keypad Black - 240 volts Mains in 230v 1N or 400v 3N Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 7: Installing The Sauna Heater

    (mm) Volume (m Distance to shelf Ceiling Floor 230V 400V 230v 400V height over 500mm above the floor OCS45 1900 1100 19.5 OCS60 1900 1100 Sauna Heater Dimensions 410 x 280 x H570mm Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 8: Sauna Heater Parts Description

      Wiring Diagram 5.3. Sauna Heater Circuit Diagram OC45~OC60 Circuit diagram   5.4. Sauna Heater Installation 3mm gap between screw head and wall Supporting Screw 6mm x 40mm (4pcs) Fig. 5.4b Fig. 5.4a Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 9: Minimum Clearances

    Open the cover with a screwdriver as in Fig. 5 iii. Fix the bottom of the temperature sensor on to wall with screw iv. Replace the cover. 1800   Fig. 6a Fig. 6b Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 10: Mini Steam Generator

    Class 3 OC-Mini-1 1000 210-240 2.1-2.3 3.2-3.6 4.2-4.8 220 x 100 x 340 OC-Mini-2 1000 1500 2000 210-240 4.2-4.6 6.4-7.2 8.4-9.6 220 x 100 x 340 7.3. Mini Steam Generator Circuit Diagram   Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 11: Parts Description

    Fix to cabin wall using 40mm Screws and the locating fixing points on the back of the heater iii. Connect the steam generator to the stauna control box (see pages 4, 9, 13) Fixing points for 40mm screw Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 12: Minimum Clearance Diagram

    A - Overflow indicator B - Tank half full C - Tank near empty - refill before use Ignore the controls on front of this unit, OC-ST stauna controller will override these functions. Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 13: Stauna Control Box

    To mini steam generator for spare usage lamp To temperature sensor 8.2. Stauna Control Parameters Model Working Time Temperature Dimension L x W x H (mm) OC-ST 15-240 30 - 100 150 x 92 x 22 Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 14: Stauna Control Circuit Diagram

    I: Po wer I np ut; II :Sa una Hea te r;II I: Mini S te am er HI-TEMP Cut Off Controller Adjust humidity (Manual Reset) (Voltage:DC5V) IV: Dvd o r Ot her; V: Ligh t;VI: Controller; VII :S ens or. Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 15 Indicates the detected temperature is lower than the preset temperature and sauna heater is heating. Indicates the detected temperature is higher than the preset temperature and the sauna heater is idling. Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 16 The C light indicates the water is too low and should be refilled. viii. If you intend to use Aromas only use Oceanic Steam Aroma – any other aromas could invalidate your warranty. Ensure the Aroma is diluted correctly and then add to the steam generator as above.
  • Page 17: Operation

    Check the water for hardness and arrange the descaling routine accordingly: - High levels of hardness descale once every 50 to 100 hours of operation. Medium levels of hardness descale once every 100 to 250 hours operation. Oceanic Saunas 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk...
  • Page 18: 11. Guarantee

    To descale the generator use a solution of weak acid crystals (such as citric acid) mixed with water Citric acid can be purchased from: www.oceanic-saunas.co.uk Descaling procedure i. iii. Fill the machine using a funnel with 1 litres of pre mixed citric acid.

This manual is also suitable for:

Ocs60

Table of Contents