EXFO ETS-1000L User Manual

EXFO ETS-1000L User Manual

Ethernet tester analyzer

Advertisement

User Guide
ETS-1000L
Ethernet Tester Analyzer

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ETS-1000L and is the answer not in the manual?

Questions and answers

Summary of Contents for EXFO ETS-1000L

  • Page 1 User Guide ETS-1000L Ethernet Tester Analyzer...
  • Page 2 EXFO Inc. (EXFO). Information provided by EXFO is believed to be accurate and reliable. However, no responsibility is assumed by EXFO for its use nor for any infringements of patents or other rights of third parties that may result from its use.
  • Page 3: Certification Information

    Electronic test and measurement equipment is exempt from FCC Part 15 compliance in the United States and from IC ICES 003 compliance in Canada. However, EXFO Electro-Optical Engineering Inc. (EXFO) makes reasonable efforts to ensure compliance to the applicable standards.
  • Page 4: Ce Declaration Of Conformity

    Quebec, Quebec Canada, G1M 2K2 Equipment Type: Information Technology Equipment (ITE) Trade Name/Model No.: Ethernet Loopback Device / ETS-1000L Standard(s) to which Conformity is Declared: EN 55022: 2006 Information technology equipment — Radio disturbance characteristics — Limits and methods of measurement...
  • Page 5: Table Of Contents

    Contents Contents Certification Information ....................... iii 1 Introducing the ETS-1000L ................1 Overview ..........................1 External Connectors ........................4 Conventions ..........................5 2 Safety Information ..................7 Laser Safety Warnings ......................7 Installation Instructions Warnings ..................8 3 Getting Started .................... 9 4 Loopback ....................11 Loopback Adjustment ......................13...
  • Page 7: Introducing The Ets-1000L

    Introducing the ETS-1000L Ethernet/Gigabit Ethernet loopback unit ETS-1000L (referred to as unit, analyzer) is intended for performing loopback at the physical, data link, network and transport layers of the OSI model. The unit allows to carry out loopback control via OAM protocol and remote control via TELNET protocol.
  • Page 8 Introducing the ETS-1000L Overview LEDs The green color of LEDs corresponds to a loopback layer. 1 — physical layer (1)  2 — data link layer (2)  3 — network layer (3)  1+3 — transport layer (4) ...
  • Page 9 Introducing the ETS-1000L Overview LED shows the data transmission state: Data Transmission State LED Colors Data is being transmitted or received green currently No data is being transmitted or received currently LED shows Ethernet interface state: Ethernet Interface State LED Colors...
  • Page 10: External Connectors

    Introducing the ETS-1000L External Connectors External Connectors You unit is equipped with the communication ports shown below: 10/100/1000 Mbps 1000 Mbps Optical with Electrical with RJ-45 SFP connector connector Unit connectors and equipment to be connected are described in the table below.
  • Page 11: Conventions

    Introducing the ETS-1000L Conventions Conventions Before using the product described in this guide, you should understand the following conventions: ARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Do not proceed unless you understand and meet the required conditions.
  • Page 13: Safety Information

    Never look directly into a live fiber, and ensure that your eyes are protected at all times. ARNING This product may employ pluggable SFP lasers.a Class 1. ARNING When the LASER LED is on, the ETS-1000L is receiving/emitting an optical signal. Ethernet Tester Analyzer...
  • Page 14: Installation Instructions Warnings

    Unauthorized modifications to this equipment shall void the user’s authority to operated this equipment. Laser Class 1 laser product. This product complies with IEC 60825-1 and 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001. ETS-1000L...
  • Page 15: Getting Started

    Getting Started Before configuring and performing tests on the ETS-1000L analyzer, turn the unit on. To turn the unit on: 1. Get the unit from the box and make the external inspection. 2. Connect the power supply unit to the electric network (if you use mains voltage 110-240 V with 50/60 Hz frequency) and to the ETS-1000L.
  • Page 17: Loopback

    Loopback The Loopback function is necessary for networks testing in compliance with the RFC 2544, as well as for a number of other tasks. This function allows to test the network without changing it’s settings. Network testing with the Loopback function can be performed at the four OSI layers, jumbo frames are supported (up to 9600 bytes).
  • Page 18 At the Network layer (L3) the incoming traffic (packets without errors)  is being retransmitted backward with source and destination IP and MAC addresses swapping. Note: Only frames with destination MAC address and destination IP address corresponding to MAC and IP addresses of the ETS-1000L are retransmitted. ETS-1000L...
  • Page 19: Loopback Adjustment

    MAC addresses swapping and source and destination TCP/UDP addresses swapping. Note: Only frames with destination MAC address and destination IP address corresponding to MAC and IP addresses of the ETS-1000L are retransmitted. Loopback Adjustment Connect the ETS-1000L to the Ethernet network and select Loopback layer by pressing L button.
  • Page 21: Remote Management

    Telnet (Telecommunication Network) is a network protocol used to access a remote unit through a personal computer. By means of the commands presented in the tables below, it is possible to configure the ETS-1000L and view its current settings. To manage unit over Telnet protocol connect ETS-1000L to personal computer through the Ethernet interface.
  • Page 22 TFTP server: on/off show vlan mode vlan state: on/off show vlan id vlan identifier show vlan priority vlan priority reboot reboot unit configure switch to configuration mode exit finish session help list of available commands ETS-1000L...
  • Page 23 Remote Management Remote management commands (Telnet) - configuration mode Command Operation ip address set interface IP address ip netmask set interface subnet mask ip gateway set gateway IP address gbe mac set interface MAC address gbe speed set interface speed: 10/100/1000/automatic gbe autonegotiation set autonegotiation mode:...
  • Page 24: Oam

    Loopback mode for the remote end. Both units should support the IEEE 802.3ah standard. ETS-1000L and remote unit should be connected directly. Possible OAM states are described below. Passive: In passive mode, the port can only response to Ethernet OAM ...
  • Page 25: Upgrading Versions Of The Software

    1. Install tftp client on yor PC (WinAgents TFTP Client for example). 2. Enter in console terminal. tftp.exe -i 192.168.1.1 put C:\work\image_X.X.X.fs When the software package file is uploaded ETS-1000L will automatically reboot. Note: If current and new versions of the software are too different, default settings are restored.
  • Page 27: Maintenance

    Maintenance To help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them and clean  them if necessary. Keep the unit free of dust.  Clean the unit casing and front panel with a cloth slightly dampened  with water.
  • Page 28: Recycling And Disposal (Applies To European Union Only)

    Maintenance Recycling and Disposal (Applies to European Union Only) Recycling and Disposal (Applies to European Union Only) For complete recycling/disposal information as per European Directive WEEE 2012/19/UE, visit the EXFO Web site at www.exfo.com/recycle. ETS-1000L...
  • Page 29: Troubleshooting

    Troubleshooting Solving Common Problems Before calling EXFO’s technical support, please read the following common problems that can occur and their respective solution. Problem Possible Cause Solution Connection is lost Incorrect cable Check cable connection   connection state Two active connections Use only one active ...
  • Page 30: Contacting The Technical Support Group

    Contacting the Technical Support Group To obtain after-sales service or technical support for this product, contact EXFO at one of the following numbers. The Technical Support Group is available to take your calls from Monday to Friday, 8:00 a.m. to 7:00 p.m.
  • Page 31: Transportation

    Troubleshooting Transportation Transportation Maintain a temperature range within specifications when transporting the unit. Transportation damage can occur from improper handling. The following steps are recommended to minimize the possibility of damage: Pack the unit in its original packing material when shipping. ...
  • Page 33: Warranty

    Warranty General Information EXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship for a period of one year from the date of original shipment. EXFO also warrants that this equipment will meet applicable specifications under normal use.
  • Page 34: Liability

    Liability Liability EXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any failure in the performance of other items to which the product is connected or the operation of any system of which the product may be a part.
  • Page 35: Exclusions

    Warranty Exclusions Exclusions EXFO reserves the right to make changes in the design or construction of any of its products at any time without incurring obligation to make any changes whatsoever on units purchased. Accessories, including but not limited to fuses, pilot lamps, batteries and universal interfaces (EUI) used with EXFO products are not covered by this warranty.
  • Page 36: Service And Repairs

    5. Return the equipment, prepaid, to the address given to you by support personnel. Be sure to write the RMA number on the shipping slip. EXFO will refuse and return any package that does not bear an RMA number.
  • Page 37: Exfo Service Centers Worldwide

    Warranty EXFO Service Centers Worldwide EXFO Service Centers Worldwide If your product requires servicing, contact your nearest authorized service center. EXFO Headquarters Service Center 400 Godin Avenue 1 866 683-0155 (USA and Canada) Quebec (Quebec) G1M 2K2 Tel.: 1 418 683-5498...
  • Page 39: A Specifications

    MPORTANT The following technical specifications can change without notice. The information presented in this section is provided as a reference only. To obtain this product’s most recent technical specifications, visit the EXFO Web site at www.exfo.com. Specifications Values Ingress protection...
  • Page 41: B Bibliography

    Bibliography [1] IEEE Std 802.1Q, IEEE Standard for Local and metropolitan area net-works — Virtual Bridged Local Area Networks. RFC 791, Postel, J., Internet Protocol, DARPA, September 1981. RFC 826, Plummer, D., Ethernet Address Resolution Protocol or converting network protocol addresses to 48.bit Ethernet address for transmission on Ethernet hardware, November 1982.
  • Page 43: Index

    Index Index IC..............iii ACT ............... 3 identification label........24 after-sales service ........24 IP Dst ............11 IP Src ............11 caution of personal hazard........5 label, identification........24 of product hazard........5 laser............7, 8 CE............. iii, iv class 1 ............
  • Page 44 ..........5 laser............7 warning ........... 5 service and repairs........30 service centers ..........31 shipping to EXFO ........30 show mode ..........16 specifications, product ........ 33 storage requirements ........21 symbols, safety..........5 TCP/UDP Dst ..........11 TCP/UDP Src ..........
  • Page 45 CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES CONTAINED IN THIS EXFO PRODUCT EXFO NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS...
  • Page 46 MARKING REQUIREMENTS MARKING REQUIREMENTS Product Environmental protection use period (years) Logo Product Environmental protection use period (years) Logo This Exfo product This Exfo product EXFO EXFO Battery Battery If applicable. If applicable.
  • Page 47 EXFO FINLAND Elektroniikkatie 2 FI-90590 Oulu, FINLAND Tel.: +358 (0) 403 010 300 · Fax: +358 (0) 8 564 5203 TOLL-FREE (USA and Canada) 1 800 663-3936 © 2014 EXFO Electro-Optical Engineering Inc. All rights reserved. Printed in Canada (2014-04) ...

Table of Contents