  • Page 1 MANUAL LANTIME M300 MSF/3GE 2nd September 2019 Meinberg Funkuhren GmbH & Co. KG...
  • Page 3: Table Of Contents

    ......3 Global Information LANTIME M300/MSF/3GE 4 Technical Specifications LANTIME Chassis...
  • Page 4: Imprint

    1 Imprint 1 Imprint Meinberg Funkuhren GmbH & Co. KG Lange Wand 9, 31812 Bad Pyrmont / Germany Phone: + 49 (0) 52 81 / 93 09 - 0 Fax: + 49 (0) 52 81 / 93 09 - 230 Internet: https://www.meinbergglobal.com...
  • Page 5: Important Safety Information

    Meinberg Funkuhren shall not be responsible for any damage arising due to non-observance of these regulations.
  • Page 6: Used Symbols

    Dieses Produkt fällt unter die B2B Kategorie. Zur Entsorgung muss es an den Hersteller übergeben werden. This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. LANTIME M300 Date: 2nd September 2019...
  • Page 7 This manual is intended exclusively for electricians or persons trained by an electrician who are familiar with the applicable national standards and safety rules. Installation, commissioning and operation of this device may only be carried out by qualified personnel. Date: 2nd September 2019 LANTIME M300...
  • Page 8: Security During Installation

    For safety reasons, the device with the highest mass should be installed in the lowest position of the rack. Other devices must be placed from the bottom to the top. The device must be protected against mechanical stress such as vibration or shock. LANTIME M300 Date: 2nd September 2019...
  • Page 9 fluids or foreign objects enter), the current flow can be interrupted. Questions about the house installation, need to be clarified with your house administration. The power supply should be connected with a short, low-inductance line. Date: 2nd September 2019 LANTIME M300...
  • Page 10 LANTIME M300 Date: 2nd September 2019...
  • Page 11: Protective Conductor- / Ground-Terminal

    (grounding rail). The mounting parts (without cable) are not included in the scope of delivery. Note: Please use a grounding cable 1.5 mm Always pay attention to a correct crimp connection! Date: 2nd September 2019 LANTIME M300...
  • Page 12: Safety During Operation

    Devices that are connected via one or more uninterruptible power supplies (UPS) remain operational even when the UPS power cord is disconnected. Therefore, you must put the UPS out of operation according to the documentation of the corresponding user documentation. LANTIME M300 Date: 2nd September 2019...
  • Page 13: Safety During Maintenance

    Risk of explosion if the battery is not replaced correctly. Replace only with the same or equivalent type recommended by the manufacturer. When disposing used batteries, observe the local regulations for the disposal of hazardous waste. Date: 2nd September 2019 LANTIME M300...
  • Page 14: Cleaning And Care

    ESD protective covers, which are extremely wrinkled or even have holes, no longer protect against electrostatic discharge. ESD protective covers must not be low-resistance and metallically conductive if a lithium battery is installed on the assembly. LANTIME M300 Date: 2nd September 2019...
  • Page 15: Return Of Electrical And Electronic Equipment

    Return and Collection Systems For returning your old equipment, please use the country-specific return and collection systems available to you or contact Meinberg. The withdrawal may be refused in the case of waste equipment which presents a risk to human health or safety due to contamination during use.
  • Page 16: Global Information Lantime M300/Msf/3Ge

    3 Global Information LANTIME M300/MSF/3GE 3 Global Information LANTIME M300/MSF/3GE The LANTIME (Local Area Network Time Server) provides a high precision time base to a TCP/IP network (Stratum-1-Server). The NTP (Network Time Protocol) is used to synchronize all NTP clients with the refer- ence.
  • Page 17: Technical Specifications Lantime Chassis

    External Ground Connection on the Housing This connector must be wired to an equipotential bonding bar (earthing bar). Connection is possible on both sides of the housing. The mounting parts (without cable) are included in the scope of delivery. Date: 2nd September 2019 LANTIME M300...
  • Page 18: M300 Msf - Rear Connectors

    - Never work with open terminals and plugs while the power is on. - All connectors must be protected against touching live parts with a suitable plug housing! - Note: Always ensure safe wiring! - Important: The device must be connected to a proper grounding (PE). LANTIME M300 Date: 2nd September 2019...
  • Page 19: Rs232 Comx Timestring

    5.2 RS232 COMx Timestring Data transfer: serial Baudrate/framing: 19200 / 8N1 (default) Timestring: Meinberg Standard (default) Assignment: Pin 2: TxD (transmit) Pin 3: RxD (receive) Pin 5: GND (ground) COM x Connection type: D-SUB female 9pin. Cable: data cable (shielded)
  • Page 20: Error Relay

    Dangerous voltages can occur at the terminal of the fault signal relay! Work on the terminal of the fault signal relay must never be carried out with the signal voltage present! LANTIME M300 Date: 2nd September 2019...
  • Page 21: Msf Antenna

    5.6 Pulse Per Minute Output Output signal PPM (pulse per minute) Signal level: TTL 2.5 V into 50 Ohm Pulse length: 200 ms Connection type: BNC, female PPM Out Cable: shielded coax line Date: 2nd September 2019 LANTIME M300...
  • Page 22: 10/100Base-T Network Port (Ieee 803.2)

    Duplex Modes: Half/Full/Autonegotiaton 5.8 1000Base-T Network Port (IEEE 802.3-2008) Output signal 1000Base-T Data transmission speed: 10/100/1000 MBit/s LAN x Connector Type: 8P8C (RJ45) Cable: Copper twisted pair, e.g. CAT 5.0 10/100/1000 Duplex Modes: Half/Full/Autonegotiaton LANTIME M300 Date: 2nd September 2019...
  • Page 23: Msf Antenna

    Surge protectors are optionally available and should be used in the antenna line to protect the receiver from high voltages spikes e.g. due to lightning strikes close to the antenna. Date: 2nd September 2019 LANTIME M300...
  • Page 24 DC current, an extra power supply is required in this case at the location of the antenna. Longwave receiver equipment from Meinberg has specifically been designed for Meinberg devices and is not necessarily compatible with receivers from 3rd party manufacturers.
  • Page 25: Mounting And Installation Of A Longwave Antenna

    Cable ca. 1,5 mm Ø fastened at the surge protector Figure: Longwave antenna mounted on a wall. The optional surge protector keeps high voltage strikes through the antenna cable away from the receiver. Date: 2nd September 2019 LANTIME M300...
  • Page 26 - Do not carry out any work on the antenna system or the antenna cable if there is a risk of a lightning strike. - Do not carry out any work on the antenna system if the safety distance to free lines and sequential circuits is exceeded. LANTIME M300 Date: 2nd September 2019...
  • Page 27: Weee Compliance

    Any transportation expenses for return- ing this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself. Date: 2nd September 2019...
  • Page 28: Declaration Of Conformity

    8 Declaration of Conformity 8 Declaration of Conformity Konformitätserklärung Doc ID: LANTIME M300/MSF/3GE-2019-09-02 Hersteller Meinberg Funkuhren GmbH & Co. KG Manufacturer Lange Wand 9, D-31812 Bad Pyrmont erklärt in alleiniger Verantwortung, dass das Produkt, declares under its sole responsibility, that the product...