117-330 XBDS Soft Fail RAP

117-330 An Ethernet error was detected.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Advise the customer to check whether HTTP and HTTPS have started up normally and
are operable.
3.
Advise the customer to check that the TCP/IP ports are correctly configured.
4.
Ensure that all connectors on the drive PWB,
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
5.
Reload the software,
GP
4.
6.
Perform the
016A
Scan to Network Error Entry RAP.
7.
If the fault persists, install a new ESS PWB,
Status Indicator RAPs
117-330, 117-331, 117-355
WARNING
GP
10.
PL 1.10 Item 3
and the ESS PWB,
PL 3.10 Item
6.
117-331, 117-355 Uninitialized RAP
117-331 An uninitialized HDD that was used for another machine was recognized.
117-355 HDD is not recognized in this startup.
Procedure
Perform the
016-210, 506, 777, 780, 798
PL 3.10
April 2017
2-536
HDD Error RAP.
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
Launch Issue

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VersaLink B7025 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Versalink b7030Versalink b7035

Table of Contents

Save PDF