Advertisement

OPERATOR'S MANUAL
ISOIL IMPIANTI S.p.A. – Italy
Sede e Stabilimento
Head office and factory
24061 Albano S. Alessandro (BG)
74, via Madonna delle Rose
Tel. +39 035 4239.011
Fax +39 035 582078
E-mail: albano@isoil-impianti.it
www.isoilmeter.com
P.D. METER TYPE
SBM 150
Uffici commerciali
Sales office
20092 Cinisello Balsamo (MI)
27, via F.lli Gracchi
Tel. +39 035 4239.011
Fax +39 02 66012457
E-mail: sales@isoil-impianti.it
ISOIL
I
M
Sede legale
Registered office
20124 Milano
24, viale Vittorio Veneto
Capitale soc. i.v. Euro 774.00
Codice fisc. E part. IVA 13066900153
C.C.I.A.A. MI – Reg. Impr. 86449/2000
P
I
A
N
T
I
CODE: MA/027/00/EN
REV:
07
DATED:
09/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SBM 150 and is the answer not in the manual?

Questions and answers

Summary of Contents for ISOIL SBM 150

  • Page 1 ISOIL OPERATOR’S MANUAL P.D. METER TYPE SBM 150 CODE: MA/027/00/EN REV: DATED: 09/2018 ISOIL IMPIANTI S.p.A. – Italy Sede e Stabilimento Uffici commerciali Sede legale Head office and factory Sales office Registered office 24061 Albano S. Alessandro (BG) 20092 Cinisello Balsamo (MI)
  • Page 3: Table Of Contents

    F : Strainer P : Preset Vp : Preset valve Check air check valve Meter register Counter VEGA ISOIL IMPIANTI updates own products without condition of advance notice. ISOIL IMPIANTI doesn’t take liabilities for use the dates that are modified...
  • Page 4  Air check valve ..............Dis. 735  Calibration mechanism ............Dis. 672  Gearing box for mounting of electronic counter Vega ..Dis. 3958 Page 4 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 5: Introduction

    The warranty does not cover devices and parts not built by Isoil Impianti S.p.A.. The warranty ceases if non-original spare parts are used; the warranty ceases too for an improper use or if the operational limits of the device are exceeded.
  • Page 6 The rotor spindle extends through a pressure tight seal in the meter front cover into the calibrating mechanism which transmits the rotor movement to the register. Page 2 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 7: General Safety Principles

     Make sure that the system operates in compliance with the relevant operational limits  All pressure parts must be inspected and serviced in accordance with national laws in force ISOIL IMPIANTI S.p.A. Page 3 All rights reserved. Reproduction of this manual is forbidden.
  • Page 8: Meter Operation

     If the meter is connected to any electric or electronic equipment, disconnect all of them from the power supply before doing any servicing or regulation operation, unless explicitly stated otherwise in the manual Page 4 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 9: Operation Precautions

     Thermal expansions that generate overpressures can easily damage the meters and the systems in general. Put safety valves for overpressure in every section that can be closed through regulation or isolation valves. ISOIL IMPIANTI S.p.A. Page 5 All rights reserved. Reproduction of this manual is forbidden.
  • Page 10: Installation

     In case the rate of flow through the installation exceeds the meter maximum rated capacity, it is advisable to use a flow limiting valve, which must be installed downstream the same meter. Page 6 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 11: Start-Up Precautions

    ISOIL IMPIANTI S.p.A. Page 7 All rights reserved. Reproduction of this manual is forbidden.
  • Page 12: Maintenance

     Remove the rotor group by using the "Rotor removal and turning tool" (see special tool). Turn the rotor so that two graphite vanes re-enter in the rotor in correspondence of the smaller radius. Page 8 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 13: Rotor Disassembling

    It is recommended to repair without varying the calibrating adjustment. CAUTION: do not remove the shimming washers between the frame and the bearing of the mechanism box. ISOIL IMPIANTI S.p.A. Page 9 All rights reserved. Reproduction of this manual is forbidden.
  • Page 14: Calibration Of Flow Meter

    AEROSHELL FLUID 31 -40+204°C MOBIL DTE 26 -10+80 °C MOBIL 1 -10+200 °C NOTE: to avoid ice forming in wintertime, add two spoons of car antifreeze. Page 10 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 15: Tests After Overhaul

    4.7 Spare parts For a correct meter maintenance use only original spare parts from Isoil Impianti S.p.A. . Isoil Impianti S.p.A. is not responsible for any problem that can result from the use of non original spare parts. 4.8 Maintenance schedule...
  • Page 16 Excess delivery beyond 1%. 1. Vane blades damaged. Inspect and replace damaged vane blades. 2. Jammed rotor or calibrating As described above. mechanism. Page 12 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 17: Special Tools

    For dismounting the internal ring of the bearing after having broken the external ring. Code 80ES0012 Vanes checking tool For measuring of the vanes length. Code 80AT0057 ISOIL IMPIANTI S.p.A. Page 13 All rights reserved. Reproduction of this manual is forbidden. MA/027/00/EN/07...
  • Page 18: Techincal Data

     Temperature range: ............. -10°C - +50°C  Flow rate: ................130-1300 lpm The value reproduced in label can change as regards to those shown in the manual Page 14 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 19 ISOIL IMPIANTI S.p.A. Page 15 All rights reserved. Reproduction of this manual is forbidden. MA/027/00/EN/07...
  • Page 20 Page 16 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 21 ISOIL Dis. 6756/M ASSIEME CONTATORE SBM 150 CON TENUTA A LABBRO Foglio 1 di 1 SBM 150 P.D. METER ASSEMBLY WITH LIP SEAL I M P I A N T I N° CODICE DESCRIZIONE Q.tà MATERIALE pos. N° CODICE DESCRIZIONE pos.
  • Page 22 ISOIL MONTAGGIO PATTINI PER CONTATORI BM E SBM 150 Dis. 758 VANES ASSEMBLY FOR P.D.METERS BM AND SBM 150 Foglio 1 di 1 I M P I A N T I COPPIA PATTINI SINISTRI COPPIA PATTINI DESTRI LEFT VANES COUPLE RIGHT VANES COUPLE COD.
  • Page 23 FILTRO DEGASATORE TIPO LS - AS - FDS 150 STRAINER AIR SEPARATOR TYPE LS - AS - FDS 150 ISOIL IMPIANTI S.p.A. Page 19 All rights reserved. Reproduction of this manual is forbidden. MA/027/00/EN/07...
  • Page 24 Carbon steel Tappo TE 3/8" Acc.inox 80TA1150 Plug St.steel Targa dati Acc. inox 80TA3603 Data plate St. steel Parti di ricambio consigliate / Suggested spare parts Page 20 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 25 ISOIL IMPIANTI S.p.A. Page 21 All rights reserved. Reproduction of this manual is forbidden. MA/027/00/EN/07...
  • Page 26 Acciaio inox 80SF0018 Floating sphere ø 110 St.steel Coppiglia a molla Acciaio inox 80COD006 Coter pin St.steel Parti di ricambio consigliate / Suggested spare parts Page 22 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 27 ISOIL IMPIANTI S.p.A. Page 23 All rights reserved. Reproduction of this manual is forbidden. MA/027/00/EN/07...
  • Page 28 Alluminio 80GO1003 Check elbow Aluminium Grano Acc. inox 80GR1006 Dowel St. steel Boccola Ottone 80BO1162 Parti di ricambio consigliate / Suggested spare parts Bush Brass Page 24 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 29 ISOIL IMPIANTI S.p.A. Page 25 All rights reserved. Reproduction of this manual is forbidden. MA/027/00/EN/07...
  • Page 30 Gomito Alluminio 80GO1003 Elbow Aluminium Rondella Acc.al carb. 80RO1018 Washer Carbon steel Boccola Ottone 80BO1162 Bush Brass Parti di ricambio consigliate / Suggested spare parts Page 26 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 31 ISOIL IMPIANTI S.p.A. Page 27 All rights reserved. Reproduction of this manual is forbidden. MA/027/00/EN/07...
  • Page 32 Bronzo Boccola a flangia Bronzo 80BO1000 80BO1000 Bush Bronze Bush Bronze Ingranaggio Acciaio 80IN3135 Parti di ricambio consigliate / Suggested spare parts Gear Carbon steel Page 28 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 33 Counter VR 7887 Coppia chiavi taratura 80COC003 Calibrat. keys Ved.pos.60 See item 60 Piattello SBM 150 DX 81PI1006 Gear pl. SBM 150 RH Piattello SBM 150 SX 81PI1003 Gear pl. SBM 150 LH Dispos. di regolazione 80DI5015 Calibrating mech. assy Anello elastico...
  • Page 34 Page 30 ISOIL IMPIANTI S.p.A. MA/027/00/EN/07 All rights reserved. Reproduction of this manual is forbidden.
  • Page 35 Carbon steel Coperchio accesso tar. Alluminio 80COB069 Calibr.inlet cover Aluminium Vite Acc. al carb. 80VI8048 Screw Carbon steel Ingranaggio Acc. al carb. 80IN3279 Gear Carbon steel ISOIL IMPIANTI S.p.A. Page 31 All rights reserved. Reproduction of this manual is forbidden. MA/027/00/EN/07...