Location And Function Of Parts - Sony BRU-300 Operating Instructions Manual

Optical multiplex unit
Hide thumbs Also See for BRU-300:
Table of Contents

Advertisement

Available languages

Available languages

Location and Function
of Parts
Front
1
2
A Power switch
Turns on/off the power of this unit.
B Power indicator
Lit in green: This unit is in normal operation.
Lit in red: The power of the camera connected to
this unit is turned off. Turn it on.
Flashing in red: Abnormal operation of this unit.
Display the composite video signal on the monitor
and check the error message. Check also the
connection.
Rear
3
VISCA RS-422
IN EXT SYNC OUT
S VIDEO
5 6
7 8
C Card slot
Insert an optional interface card such as BRBK-301
or BRBK-302.
The slot cover is attached at the factory.
D AC IN connector
Connect the supplied AC power cord.
E EXT SYNC IN connector
Accepts external video sync signals.
4
~
AC IN
FUNCTION
IN
OUT
1
6
VISCA RS-232C
CAMERA
9
0
qaqs
qd
F EXT SYNC OUT connector
Supplies external video sync signals.
G Composite video output connector
Supplies the images from the camera connected to
this unit as composite signals.
H
S VIDEO connector
Supplies the images from the camera connected to
this unit as Y/C separate (S video) signals.
I VISCA RS-422 connector
Connect to the VISCA RS-422 connector of the
camera or another BRU-300/300P Optical
Multiplex Unit.
For the connection to the VISCA RS-422
connector, see "Using the VISCA RS-422
Connector Plug" on page 9.
J VISCA FUNCTION switches
These switches are used for the VISCA
communication settings.
Switch 1 (RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2 (Communication baud rate
selector)
Set to ON for 38400bps, or OFF for 9600bps.
Switches 3 to 5 (Camera address selectors)
Set the address of the camera.
Normally set to "0". With this setting, addresses are
assigned to the cameras automatically in the
connected order by pressing the POWER button
while holding down the RESET button on the RM-
BR300 Remote Control Unit (not supplied).
You can assign the camera address "1" to "7"
manually by setting these selectors as follows:
Camera
0
1
address
Switch 3 OFF ON OFF ON OFF ON OFF ON
Switch 4 OFF OFF ON ON OFF OFF ON ON
Switch 5 OFF OFF OFF OFF ON ON ON ON
Note
Switch 6 is not used.
2
3
4
5
6
7

Location and Function of Parts

5
GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bru-300p

Table of Contents