Pylon Technologies LV-Hub Series Product Manual

Communication hub
Hide thumbs Also See for LV-Hub Series:

Advertisement

Quick Links

Communication HUB
LV-Hub Product Manual
Information Version: 1.0
No. 73, Lane 887, ZuChongzhi Road, Zhangjiang Hi-Tech Park
Pudong, Shanghai 201203, China Zip Code: 201203
1 / 9
Pylon Technologies Co., Ltd.
Email:
service@pylontech.com.cn
Website:
http://www.pylontech.com.cn
Tel: 021-51317697
Fax: 021-51317698
18BISV0501

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LV-Hub Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Pylon Technologies LV-Hub Series

  • Page 1 Communication HUB LV-Hub Product Manual Information Version: 1.0 Pylon Technologies Co., Ltd. No. 73, Lane 887, ZuChongzhi Road, Zhangjiang Hi-Tech Park Pudong, Shanghai 201203, China Zip Code: 201203 Tel: 021-51317697 Fax: 021-51317698 Email: service@pylontech.com.cn Website: http://www.pylontech.com.cn 1 / 9 18BISV0501...
  • Page 2: Table Of Contents

    This manual introduces LV-Hub from Pylontech. LV-Hub is a communication hub for US2000B Plus/US3000 Lithium-Ion Phosphate Battery storage system. Please read this manual before you install the battery and follow the instruction carefully during the installation process. Contents INTRODUCTION ..........................3 LV-HUB-A ............................
  • Page 3: Introduction

    1. Introduction LV-Hub is the CAN/RS485 communication hub for multiple 48V battery groups in parallel connection. Fit Description: US2000B Plus / Phantom-SA / US3000 / US1800. 2. LV-Hub-A If the power supply is 220Vac, an adaptor (220Vac to 12Vdc) will be provided. Item Parameter Operating voltage range...
  • Page 4: Definition Of Rj45 Port Pin

    Part Silk-screen Function 6: Up:CAN OUT terminal resistance 120Ω Dip switch 1 - 6 Down:0Ω CAN output port (only upper port is for RJ45 CAN OUT using); RJ45 RS232 Debug Connect to port 0 (only for CAN RJ45 CAN IN communication);...
  • Page 5: Led Indicators Instructions

    2.3 LED Indicators Instructions ● Normal No battery connected or at least one group is off line. Status ● When battery group is reduced it will alarm (in red), but when battery group is added in it will no alarm. Green flash;...
  • Page 6: Cables Connection For Can

    RS485 communication needn’t additional cable and power just a simple hub is enough.  When each battery group’s current is >120A, this battery group must configure 2 pair  external power cables like the diagram. The details of ADD Switch setting also can see the menu of battery. ...
  • Page 7: Annex 1: Cables Connection For Rs485

    Annex 1: Cables Connection for RS485 7 / 9 18BISV0501...
  • Page 8: Annex 2: Cables Connection For Can

    Annex 2: Cables Connection for CAN 8 / 9 18BISV0501...
  • Page 9 Pylon Technologies Co., Ltd. No. 73, Lane 887, ZuChongzhi Road, Zhangjiang Hi-Tech Park Pudong, Shanghai 201203, China +86-21-51317697 | +86-21-51317698 service@pylontech.com.cn www.pylontech.com.cn 9 / 9 18BISV0501...

This manual is also suitable for:

Lv-hub-a

Table of Contents