Page 1
Additional manuals are available from your WELLS DEALER. THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any questions concerning installation, operation or maintenance of this equipment.
Page 2
Wells’ discretion have the parts replaced or codes, including incorrect gas or electrical connection. Wells is not liable repaired by Wells or a Wells-authorized service agency.
PARTS & SERVICE CUSTOMER SERVICE DATA INTRODUCTION Thank You for purchasing this Wells Manufacturing appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
NOTE: The dial position is an indication of the temperature setting. Actual temperature will vary depending upon the type of product and food consistency. MOUNTING HMP6 Series warmers require a cutout and mounting holes in the counter top.See the Installation Instructions, supplied with the particular warmer, for details.
Do not operate this appliance if the control panel is damaged. Call installation instructions are your Authorized Wells Service Agent for service. read and followed. Damage to the appliance may result The technical content of this manual, including any wiring diagrams,...
INSTALLATION NOTE: DO NOT discard UNPACKING & INSPECTION the carton or other packing Carefully remove the appliance from the carton. Remove all protective materials until you have plastic film, packing materials and accessories from the Appliance inspected the appliance for before connecting electrical power or otherwise performing any hidden damage and tested it installation procedure.
Page 7
INSTALLATION Top-Mounted Warmers NOTE: Damage caused by leaks due to improper Verify that provided sealants are applied to the underside of the installation is NOT covered by warmer top flange prior to setting the unit into the cutout. warranty. After installation, verify that all supplied fasteners and other mounting hardware is properly installed and tightened.
CAUTION: change in wet or dry operation. SHOCK HAZARD Wells Manufacturing recommends operating WET for consistent food heating. DO NOT splash or pour water If your wet-operation warmer is allowed to run dry, turn it OFF and onto control panel or wiring.
Never use metal implements, wire brushes, abrasive scratch pads or steel wool to clean stainless steel. Warmer pans, insets and other vessels are subject to a harsher environment. Wells Manufacturing uses an very high quality stainless steel (#304DDQ) for our food warmer pans.
Contact your Authorized Wells Service Agency to inspect warmer if water or grease contamination is suspected. Close drain valve. Add proper amount of warm water. Turn control...
Page 11
CLEANING INSTRUCTIONS CAUTION: WEEKLY CLEANING INSTRUCTIONS CHEMICAL BURN PREPARATIONS: Remove any insets, pans and/or adapter tops. HAZARD Drain or remove water from well if used for wet operation. Deilimng chemicals may be caustic. Wear appropriate FREQUENCY: Weekly, or whenever lime or scale is seen personal protective equipment.
Drain-equipped unit will not hold water Contact your Authorized Wells Service Drain valve damaged or pan(s) leaking Agency for repairs There are no user-serviceable components in this appliance. In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
EXPLODED VIEW & PARTS LIST MODEL HMP-6 PAN ASSEMBLY P2-305802 ELEMENT PAN ELEMENT CLIP WS-505643 2C-30397 HEATING ELEMENT 2N-45431UL STRAIGHT CONDUIT FITTING 2K-37748X PILOT LIGHT RETAINER CLIP K-TYPE THERMOSTAT CONTROL 2C-63271 2T-38968 2T-46551, 91” INCH CAP RED LIGHT SIGNAL THERMOBULB 2J-35687 BRACKET D8-303352...
Page 14
EXPLODED VIEW & PARTS LIST MODEL HMP-6D DRAIN SCREEN ASSEMBLY 2V-Z17446 PAN ASSEMBLY P2-41463 PILOT LIGHT RETAINER CLIP 2C-43271 OVAL CONTROL K-TYPE PANEL THERMOSTAT 2V-WL0049 2T-38968 RED LIGHT SIGNAL 2J-35687 POP RIVET 2C-34284 HEATING CONTROL KNOB ELEMENT ASSEMBLY 2N-45431UL ELEMENT 2R-40498 CLIP 2C-30397...
Page 15
EXPLODED VIEW & PARTS LIST MODEL HMP-6ULD DRAIN SCREEN ASSEMBLY Wireset for HMP6DU6 2V-Z17446 use P2-41317A PAN ASSEMBLY P2-41463 K-TYPE THERMOSTAT 2T-38968 CONTROL BOX (6’ use 2T-46551) P2-306959 PLATE, THERMO RED LIGHT P2-45614 SIGNAL CONTROL 2J-35687 PANEL I7-Z12221 ELEMENT CLIP 2C-30397 HEATING ELEMENT...
Need help?