10 Series Owner’s Manual Table Of Contents PREFACE PRE-INSTALLATION INSTALLATION AND START UP SETTING & USING THE SYSTEMS CONTROL ENGINEERING SPECIFICATIONS MODE I SETTING CHART MODE II SETTING CHART TROUBLE-SHOOTING PARTS – WATERMAX HOOK-UP/COVER ASSEMBLY PARTS – WATERMAX BRINE TANK ASSEMBLY PARTS –...
3. Protect your WaterMax, including the drain line, from freezing. 4. Should dirt, sand, or large particles be present in your water supply, it is important that you consult your Hague dealer for filters that will eliminate this problem. 5. Bypass the appliance(s) if well, plumbing, or pump work is required, and turn on outside tap until water runs clear before putting the appliance back in service.
10 Series Owner’s Manual PRE-INSTALLATION 1. Water Pressure — Not less than 20 psi nor greater than 120 psi. 2. Minimum Service Flow Rate Available to the appliance — 3 gpm or equal to backwash flow rate of your particular model. (See Engineering Specifications, Page 12.) 3.
Page 5
10 Series Owner’s Manual Where To Locate The 10 Series Where you will locate the 10 Series depends on what other water treatment equipment you currently have installed. The 10 Series should be located: After: Before: Water Meter Water Heater Pressure Tank TYPICAL 10 SERIES INSTALLATION Figure 1...
10 Series Owner’s Manual INSTALLATION AND START UP 1. Place the 10 Series in the desired location. Turn off the electricity and/or water supply to the water heater. Make sure the inlet, outlet and drain connections meet the applicable local codes. Check arrows on the bypass valve to be sure the water flows in proper direction.
10 Series Owner’s Manual 12. Fill the brine tank with salt.* Note: Do not mix pellet with solar salt! 13. Open the inlet valve and turn on the electricity to the water heater. To complete the installation, open a cold water tap and allow the appliance to flush for 20 minutes or until approximately 72 gallons have passed through the appliance.
Page 8
10 Series Owner’s Manual Press and hold (approximately 3 seconds) until display changes to “Set language???”. Use the NEXT button to step through parameters that can be set. (B) IMMEDIATE RECHARGE FUNCTION: Used to put the appliance into an immediate regeneration. Press and hold (approximately 5 seconds) until display changes to “Going to 1”.
Page 9
10 Series Owner’s Manual Control Panel Display (F) LCD DISPLAY FUNCTION: Shows status of control; NORMAL OPERATING mode, SERVICE SETTINGS mode or CUSTOMER SETTING mode. It is very important to know which mode the control is in for proper operation. (G) WATER FLOWING INDICATOR LIGHT FUNCTION: When light is blinking, it indicates that water is flowing through the WaterMax.
Page 10
10 Series Owner’s Manual Push the SERVICE SETTINGS button to enter SERVICE SETTINGS mode. The display will show: Set language??? This parameter is used to set the language that is displayed in the CUSTOMER SETTINGS mode: ENG – English, FRA – French, ESP – Spanish, DEU – German, ITA – Italian. 1.00 Push the CHANGE DIGIT button until the correct language is displayed.
Page 11
10 Series Owner’s Manual 3.06a Push the SELECT and CHANGE buttons until the desired chlorine number is reached. In this example, set to: Chlor. ppm 000 3.07 Push the NEXT button to step to the next Parameter. The display will show: Sulfur ppm This parameter is used to record the tested sulfur content of the water.
Page 12
10 Series Owner’s Manual This parameter is used to calculate a compensated hardness automatically. 7.00a Push the SELECT and CHANGE buttons until the desired iron number is displayed. Example: Iron ppm 002 8.00 Push the NEXT button to step to the next parameter. The display will show: Mang. ppm ### 8.00a Push the SELECT and CHANGE buttons until the desired manganese number is displayed.
Page 13
10 Series Owner’s Manual monitor water usage properly. 17.00a Push the SELECT and CHANGE buttons until the correct value is displayed. In this example, set to: Turbine # 135 18.00 Push the NEXT button to step to the next parameter. The display will show: Reg.
10 Series Owner’s Manual TROUBLE-SHOOTING PROBLEM CAUSE ACTION No soft water after No salt in brine tank. Add salt. regeneration. Sediment in brine tank has Remove the brine line and flush plugged the brine line and/or clean. Clean air check. Clean air check.
Page 18
10 Series Owner’s Manual TROUBLE-SHOOTING PROBLEM CAUSE ACTION Appliance is plumbed in backward. Check that appliance is plumbed properly. (See Fig 1, pg. 3.) Sensor not receiving signal from Remove sensor from bypass Magnet. (See Fig. 7, pg. 23.) housing. Test with magnet on each flat side of sensor.
Page 19
10 Series Owner’s Manual TROUBLE-SHOOTING PROBLEM CAUSE ACTION Broken valve assembly. Motor Repair drive end cap. (See Fig. 8, p. 25.) running. Magnet disk not turning. Excess water in brine tank. Restricted, frozen or pinched Remove restriction, thaw or drain line. (See Fig. 1, pg. 3.) straighten drain line.
10 Series Owner’s Manual PARTS -- - WATERMAX TANK -- - CABINET ASSEMBLY PART # DESCRIPTION 90613 Resin Tank (3 comp.) 90632 Resin Tank (2 comp.) 9530IT-JG Drive End Cap Assembly 90615 Bypass Assembly 90614 Drain End Cap Assembly 90240MT Media Tank Cabinet 90237 Support Panel...
10 Series Owner’s Manual PARTS -- - WATERMAX INJECTOR ASSEMBLY Figure 6 PART # DESCRIPTION 93223 Injector Throat 93220 Bottom Injector Seal - thick 93221 Injector Nozzle 93232 Top Injector Seal - thin 93222 Injector Cap 90807 Injector Screw 93810 Injector Screen 93501 Injector Assembly (Contains all of the above...
Page 24
10 Series Owner’s Manual 93223 Injector Throat: In conjunction with the Injector Nozzle, Part # 93221, it creates the vacuum that draws the brine solution from the brine cabinet. The center hole should be clear of debris, round and undamaged. The Throat should be pressed flush into the opening in the valve. If the Throat is removed, it must be replaced with a new one.
10 Series Owner’s Manual PARTS -- - WATERMAX BYPASS ASSEMBLY Figure 7 PART # DESCRIPTION 90245 Turbine Axle 90246 Bypass Housing 90522 Turbine 90262 Bypass Endcap - left 90807 End Cap Mounting Screw 90263 Bypass Endcap - right 93808 End Cap O-ring 90218 Bypass Piston Drive Shaft 90803...
Page 26
10 Series Owner’s Manual 90246 Bypass Housing: Makes the connection between reaches the stop at either position, it can be backed off the plumbing and Main Valve Body. Also, contains the up to one half turn of the handle and still achieve a seal. “Hard Water”...
10 Series Owner’s Manual PARTS -- - WATERMAX DRIVE END CAP ASSEMBLY Figure 8 PART # DESCRIPTION 90818 Brine Valve Housing Screw 93583 Drive End Cap 90809 Cam Cover Screw 90217 Drive Motor 93808 Drive End Cap O-ring -large 93216 Piston Slide 93522-A Drive Piston Assembly...
Page 28
10 Series Owner’s Manual DRIVE END CAP ASSEMBLY 93583 Drive End Cap: Seals the two openings on the Main Valve Body. The larger diameter opening is sealed with an O-ring used as an axial or “face” seal. The O-ring sits in a groove in the End Cap. This groove must be free of defects such as pits or scratches and also free of debris.
10 Series Owner’s Manual PARTS -- - WATERMAX BRINE VALVE HOUSING ASSEMBLY PART # DESCRIPTION Figure 9 93511-A Housing 93243-JG Housing Cap Assembly 90521 Piston Assembly 93805 Housing O-ring 90843 .5 gpm Flow Control 90807 Screw 93803 Brine Valve Housing O-ring 200199 3/8”...
Page 30
10 Series Owner’s Manual BRINE VALVE HOUSING ASSEMBLY 93511-A Housing: Should have a Quad-ring for the Piston seal. The Quad-ring, P/N 93878, is held in place by the brine valve retainer, P/N 93254. The brine valve housing, P/N 93511-A, has four retaining lugs that secure the brine valve retainer.
10 Series Owner’s Manual PARTS - FILL PLUG ASSEMBLY (1) 90238 Fill Plug: The Fill Plug seals the media access ports in the Media Tank. Care should be taken that the O- ring seal areas are kept clean and free of debris. Also, both O-rings should be in the proper locations, one under the flange and one in the groove.
10 Series Owner’s Manual PARTS -- - DRAIN END CAP ASSEMBLY (1) 90268 Drain End Cap: Seals the left opening on the Main Valve Body. The opening is sealed with an O-ring used as axial or “face” seal. The O-ring sits in a groove in the End Cap. This groove must be free of defects such as pits or scratches and also free of debris.
10 Series Owner’s Manual PARTS -- - WATERMAX SAFETY SHUTOFF ASSEMBLY PART # DESCRIPTION Figure 12 51366 Air Check Elbow Assembly H7041 Guide and Lock Set H7039 Float Grommet H7040 Bell Float H7042 Float Washer H7038-01 Float Rod 90102 3.5 X 26.5 Brine Well C0700 2-Pc.
10 Series Owner’s Manual PARTS -- - BRINE VALVE ELBOW INSTALLATION INSTRUCTIONS Figure 13 The nut, gripper and retainer sleeve are a 3 piece assembly that can come apart if removed from the elbow body. Parts must be re-assembled exactly as shown to function properly. When connecting the 3/8"...
10 Series Owner’s Manual PARTS -- - BRINE CABINET DATA Based on the water level measured from the bottom of the WATERMAX brine cabinet WITH GRID PLATE, the following depths correlate to the amount of salt used per regeneration: DEPTH SALT (inches) (lbs.)
AND RETURNED BY THE ORIGINAL OWNER TO HAGUE Hague Quality Water International will not be liable for, nor will it pay QUALITY WATER INTERNATIONAL WITHIN 30 DAYS OF service call or labor charges incurred or expended with respect to this INSTALLATION.
Page 40
NSF listed or FDA approved. Made in USA Hague Quality Water International Manufactured using one or more of the 4343 S. Hamilton Rd. following patent numbers: 5,089,140 Groveport, OH 43125 5,300,230 DES.332,480 DES.331,097...
Need help?
Do you have a question about the Watermax 10 Series and is the answer not in the manual?
Questions and answers