Hide thumbs Also See for PXIe-4303:

Advertisement

Quick Links

NI PXIe-4303 User Manual And Specifications

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXIe-4303 and is the answer not in the manual?

Questions and answers

Summary of Contents for NI PXIe-4303

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2: Table Of Contents

    NI PXIe-4303 (NI PXIe-4302/4303) simultaneous filtered modules with the TB-4302 and TB-4302C terminal blocks. Driver support for the NI PXIe-4302/4303 was first available in NI-DAQmx 15.1. For the list of devices supported by a specific release, refer to the NI-DAQmx Readme, available on the version-specific download page or installation media.
  • Page 3: Electromagnetic Compatibility Guidelines

    To ensure the specified EMC performance, the length of all I/O cables Caution must be no longer than 30 m (100 ft). 2 | ni.com | NI PXIe-4302/4303 and TB-4302/4302C Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 4: What You Need To Get Started

    What You Need to Get Started To set up and use a NI PXIe-4302/4303 module with a TB-4302/4302C terminal block, you need the following items:  Hardware – NI PXIe-4302/4303 module – TB-4302/4302C terminal block – NI PXI Express chassis –...
  • Page 5: Unpack And Install The Module

    Unpack and Install the Module Remove the packaging and inspect the module. Contact NI if the module is damaged. Do not install a damaged module. The module is static sensitive. Always properly ground yourself and the Caution equipment when handling or connecting to the module.
  • Page 6: Connect The Signals

    Loosen the strain-relief screws and remove the strain-relief bar. Prepare the shielded signal wire by stripping the insulation no more than 7 mm (0.28 in.). NI PXIe-4302/4303 and TB-4302/4302C | © National Instruments | 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 7 The NI PXIe-4302/4303 User Manual provides more detailed wiring information. Make sure no exposed wire extends past the screw terminal. Exposed wire increases the risk of a short circuit that can cause circuit failure.
  • Page 8 AIGND VSUP FOR PATENTS: NI.COM/PATENTS Refer to the NI PXIe-4302/4303 User Manual for wiring diagrams showing Note how to connect sensors to the TB-4302/4302C. Tighten the terminal screws to a torque of 0.2 to 0.25 N · m (1.77 to 2.21 lb · in.).
  • Page 9: Install The Terminal Block

    Refer to Figure 6 to install the terminal block on the module while completing the following steps: Move the TB-4302/4302C into position in front of the NI PXIe-4302/4303 and engage the alignment feature with the guide on the associated module.
  • Page 10 Attach the TB-4302/4302C to the NI PXIe-4302/4303 module by pushing the terminal block straight into the module. A spring mechanism will lock in the bottom of the terminal block. Tighten the mounting screw at the top of the TB-4302/4302C to attach it to the NI PXIe-4302/4303 module.
  • Page 11: Confirm Ni Pxie-4302/4303 Module Recognition

    Confirm NI PXIe-4302/4303 Module Recognition To confirm module recognition, complete the following steps: Software support for the NI PXIe-4302/4303 is provided by NI-DAQmx. The Note DAQ Getting Started Guide, which you can download at , offers ni.com/manuals step-by-step NI-DAQmx instructions for installing software and hardware, configuring channels and tasks, and getting started developing an application.
  • Page 12: Run Test Panels

    Take an NI-DAQmx Measurement NI-DAQmx Channels and Tasks Refer to the NI-DAQmx Help for complete information about channels and tasks. Use the DAQ Assistant to configure virtual channels and tasks in MAX or in your application. Configure a Task Using the DAQ Assistant in MAX...
  • Page 13: Use Your Ni Pxie-4302/4303 Module In An Application

    Click Run. Use Your NI PXIe-4302/4303 Module in an Application For NI software version compatibility, refer to the NI-DAQmx Readme, available from Start» All Programs»National Instruments»NI-DAQmx. To get started with data acquisition in your application software, refer to the tutorials listed in Table 1.
  • Page 14: Terminal Block Removal

    Raise the latch release using a flathead screwdriver to disengage the latch. With the latch release raised, grasp the terminal block and pull it away from the module. Figure 8. Removing the TB-4302/4302C from the NI PXIe-4302/4303 Module Mounting Screw PXIe Controller...
  • Page 15: Module Removal

    Figure 9. Removing NI PXIe-4302/4303 Modules Captive Screws (Use to remove modules.) Front Panel (Do not use to remove modules.) 14 | ni.com | NI PXIe-4302/4303 and TB-4302/4302C Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16: Create A Simulated Device

    Create a Simulated Device To run examples without the hardware installed, use an NI-DAQmx simulated device. To create a simulated device in MAX: Launch MAX. Right click Devices and Interfaces»Create New. From the dialog, select Simulated NI-DAQmx Device or Modular Instrument.
  • Page 17: More Information

    Note information about maintaining optimal forced-air cooling for PXI/PXI Express devices. More Information After you install NI-DAQmx, the NI-DAQmx documentation is available from Start»All Programs»National Instruments»NI-DAQmx. Additional resources are online at ni.com/ gettingstarted You can access online device documentation by right-clicking your module in MAX and selecting Help»Online Device Documentation.
  • Page 18: Calibration Interval

    Combines CJC sensor accuracy and temperature difference between the CJC sensor and each screw terminal. Represents performance for wire gauge of 24 AWG. NI PXIe-4302/4303 and TB-4302/4302C | © National Instruments | 17 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 19: Physical

    Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) Relative humidity range........10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) 18 | ni.com | NI PXIe-4302/4303 and TB-4302/4302C Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20: Storage Environment

    MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. NI PXIe-4302/4303 and TB-4302/4302C | © National Instruments | 19 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 21: Electromagnetic Compatibility

    , search by model number or product line, and click the appropriate link in the certification Certification column. 20 | ni.com | NI PXIe-4302/4303 and TB-4302/4302C Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22: Environmental Management

    . This page contains the environmental regulations and ni.com/environment directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) At the end of the product life cycle, all products must be sent to a EU Customers WEEE recycling center.
  • Page 23 NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.
  • Page 24 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

This manual is also suitable for:

Pxie-4302Tb-4302Tb-4302c

Table of Contents