Disabling Pulse Washing; Exiting Diagnostics Mode - Kuppersbusch EDW 1503 Service Manual

Hide thumbs Also See for EDW 1503:
Table of Contents

Advertisement

40
8.5.2

Disabling pulse washing

Certain programmes use the pulse washing system (pw). Using the procedure described below, the
Service Engineer can modify this system so that "Ctrl" (continuous) washing is used in all those
programme which normally use the pulse washing system. This intensifies the washing action even in
delicate programmes.
1.
Access diagnostics mode. (See "Accessing
diagnostics mode" on page 36.)
2.
Press buttons S2-S3 simultaneously. The
display indicates the status of the function:
[0P] continuous washing "Ctrl"; [1P] pulse
washing "pw" active.
1.
Press button S2 to activate and disactivate
this function:
-
[0P] continuous washing "Ctrl"
-
[1P] pulse washing "pw" active
2.
To store this operation in memory: press
button S0 to switch the appliance off, or wait
for 60 seconds (LD1 - LD6 light).
8.6

Exiting diagnostics mode

1.
To exit the diagnostics cycle, press key S0
and switch the appliance off, or
2.
wait 60 seconds: the appliance returns to
programme selection mode.
DIVA Service Manual - EDW 1503
For internal use only

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EDW 1503 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Edw 1003