Welcome
Congratulations on the purchase of your new Osstell® IDx.
Before you start using your Osstell IDx, please read through the entire manual.
Table of content
1) Table of content
2) Warnings and Precautions
3) Indications for use
4) Description
5) Safety Symbols
6) Before You Start
7) Preparation and Set-up
8) How to Measure
9) View Measurement
10) Measure in the Classic Mode
11) View Measurement
12) Interpret the Result
13) Cleaning and Maintenance
14) Firmware update
15) Backup
16) Technical information
17) Troubleshooting
18) Service
18
2) Warnings and Precautions
Warning: The Probe emits an alternating magnetic i eld that potentially could interfere with cardiac
pacemakers!
Precautions:
• Do not use the device in the presence of explosive or l ammable materials.
• To avoid interference with other equipment, the probe should not be held
close to electronic devices.
• Use only the power supply provided with the instrument.
• SmartPegs™ are for single use only.
• The Osstell IDx Probe and the SmartPeg Mount must be sterilized before use.
3) Indications for use
18
Osstell IDx is indicated for use in measuring the stability of implants in the oral cavity and maxillofacial region.
19
Intended user proi le: clinical professionals. No special experience/training is needed.
19
19
4) Description
The Osstell IDx has a built-in patient database and enables the user to connect measurements to implant
20
position and patient through the touch screen. The Osstell IDx involves the use of the noninvasive technique,
Resonance Frequency Analysis for measuring implant stability in the oral cavity and the maxillofacial region.
20
The Osstell IDx system includes the use of a SmartPeg which is attached to an implant or abutment using the
20
SmartPeg Mount. The SmartPeg is activated by magnetic pulses from the probe, which is connected to the in-
strument. The resonance frequency, which is the measure of implant stability, is calculated from the response
21
signal. Results are presented on the instrument display as an ISQ value (Implant Stability Quotient), which is
22
scaled from 1 to 100. The higher the number, the greater the stability. The i rst measurement is taken at implant
installation to get a baseline for future measurements. Before the i nal restoration, a second measurement
22
is taken which makes it possible to observe the stability of the implant. With the graphical view, the implant
stability development can be monitored. The sot ware (i rmware) can be updated online thanks to internet
23
connectivity. Osstell IDx can add important information to the evaluation of implant stability and can be used
as part of an overall treatment evaluation program. The i nal implant treatment decisions are the responsibility
23
of the clinician.
23
The SmartPeg is available with dif erent connection geometries to i t all major implant products on the market.
24
www.osstell.com
On
24
Your Osstell IDx system includes the following items:
24
Osstell IDx Instrument
1
Osstell ISQ Probe
2
25
Osstell SmartPeg Mount
3
25
Osstell TestPeg
4
Osstell Charger
5
Osstell Plug Adapter
Osstell IDx manual
Applied Parts:
Osstell ISQ probe
you can i nd all available SmartPegs.
1
2
English
3
4
5
19