Pioneer PDP-5010FD Service Manual

Pioneer PDP-5010FD Service Manual

Plasma display system
Hide thumbs Also See for PDP-5010FD:
Table of Contents

Advertisement

PLASMA DISPLAY SYSTEM
PDP-5010FD
THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).
Model
PDP-5010FD
KUCXC
PDP-5010FD
KUC
For details, refer to "Important Check Points for good servicing".
PIONEER CORPORATION
PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A.
PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium
PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singapore 159936
PIONEER CORPORATION 2007
Type
Power Requirement
AC 120 V
AC 120 V
4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan
PDP-5010FD
T-IZS-001 JULY 2007 Printed in Japan
ORDER NO.
ARP3455
Remarks

Advertisement

Table of Contents
loading

Summary of Contents for Pioneer PDP-5010FD

  • Page 1 PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singapore 159936...
  • Page 2: Safety Information

    Therefore, the following checks should be performed for the continued protection of the customer and servicetechnician. PDP-5010FD...
  • Page 3 PRODUCT SAFETY NOTICE With the AC plug removed from an AC power source, place a Many electrical and mechanical parts in PIONEER set have jumper across the two plug prongs. Turn the AC power switch on. special safety related characteristics. These are often not evident...
  • Page 4 To protect products from damages or failures during transit, the shipping mode should be set or the shipping screws should be installed before shipment. Please be sure to follow this method especially if it is specified in this manual. PDP-5010FD...
  • Page 5: Table Of Contents

    5.5.2 FUNCTION OF DECREASING THE BRIGHTNESS LEVEL ................. 73 5.6 OUTLINE OF THE OPERATION ..........................74 5.6.1 PANEL DRIVE-POWER ON / OFF FUNCTION ..................... 74 5.6.2 SPECIFICATION OF THE FAN CONTROL......................75 5.6.3 PROCESSING IN ABNORMALITY ........................76 5.6.4 TRAP SWITCH............................... 79 PDP-5010FD...
  • Page 6 10.4 CHASSIS SECTION (1/2) ............................174 10.5 CHASSIS SECTION (2/2) ............................176 10.6 PANEL CHASSIS SECTION .............................178 10.7 MULTI BASE SECTION ............................180 10.8 PDP SERVICE ASSY 508F (AWU1272)........................182 10.9 TABLE TOP STAND ..............................184 10.10 SPEAKER SYSTEM (PACKING) ..........................185 10.11 CS ASSY ................................186 PDP-5010FD...
  • Page 7: Service Precautions

    Compared with eutectic solders, lead-free solders have higher bond strengths but slower wetting times and higher melting temperatures (hard to melt/easy to harden). The following lead-free solders are available as service parts: • Parts numbers of lead-free solder: GYP1006 1.0 in dia. GYP1007 0.6 in dia. GYP1008 0.3 in dia. PDP-5010FD...
  • Page 8: Charged Section And High Voltage Generating Point

    : Part is Charged Section. : Part is the High Voltage Generating Points other than the Charged Section. 50F Y DRIVE Assy POWER SUPPLY Unit 50F X DRIVE Assy Conductive plate X AC inlet Power switch Fig. High Voltage Generating Point (Rear view) PDP-5010FD...
  • Page 9: Specifications

    (SDS1202) Cleaning cloth (AED1285) Bracket Assy (S): ×2 (SXG1127) Warranty card Brackets for side: ×2 Operating instructions Bracket Assy (C) (PDP-5010FD/KUCXC) (SXG1128) (ARE1472) Brackets for center Operating instructions (PDP-5010FD/KUC) Speaker mounting screw (M5 x 10 mm: Black): ×9 (ARE1487) (BMZ50P100FTB)
  • Page 10: Specifications

    HDCP (High-bandwidth Digital Content Protection) is a technology used to protect copyrighted digital contents that use the Digital Visual Interface (DVI). ** This conforms to USB 1.1 and 2.0 . • Design and specifications are subject to change without notice. Dimensions 120 (4-23/32) 1232 (48-1/2) 550 (21-21/32) 300 (11-13/16) Unit: mm (inch) PDP-5010FD...
  • Page 11: Panel Facilities

    14 INPUT 3 terminals (COMPONENT VIDEO: Y, P 4 SLEEP indicator 5 Room Light Sensor 15 INPUT 3 terminal (VIDEO) 6 Remote control sensor 16 INPUT 3 terminals (AUDIO) 7 STANDBY/ON button The buttons with asterisks (*) can operate the TV Guide On Screen™ system. PDP-5010FD...
  • Page 12 11 RS-232C terminal (used for factory setup) 26 SPEAKERS (R) terminal (Speaker side) 12 ANT B IN terminal 27 SPEAKERS (L) terminal (Speaker side) 13 INPUT 1 terminal (S-VIDEO) 14 INPUT 1 terminal (VIDEO) 15 SUB WOOFER terminal 16 AUDIO OUT terminals (AUDIO) PDP-5010FD...
  • Page 13 All buttons on the remote control unit are luminous and gather and store light. This enables quick access to the desired function when performing operations in dark places. Mode switch (with “TV” selected) Note • When using the remote control unit, point it at the plasma display. PDP-5010FD...
  • Page 14: Basic Items For Service

    Item to be checked regarding video Item to be checked regarding audio Block noise Distortion Horizontal noise Noise Dot noise Volume too low Disturbed image (video jumpiness) Volume too high Too dark Volume fluctuating Too bright Sound interrupted Mottled color PDP-5010FD...
  • Page 15: Quick Reference

    [j] seven times.) 2 Press [l] to select "CLEAR". Hold [ENTER/SET] pressed for at least 5 seconds. 2. Press [ENTER/SET], then select a Mask indication, using [i] or [j]. After clearance is completed, "ETC" is automatically selected. PDP-5010FD...
  • Page 16 50. PTN MASK 49 11. COMBI MASK SETUP (+) 1. MASK OFF 2. CMB MASK 01 For use while Combination Mask is displayed. • • • • • Use [i] or [j] to select the type of mask. 18. CMB MASK 17 PDP-5010FD...
  • Page 17: Pcb Location

    IC3101 - IC3104 AN16174A FHD POWER SW ASSY AWW1293 50F X DRIVE ASSY AWV2510 POD ASSY AWW1295 50F Y DRIVE ASSY AWV2511 > PANEL SENSOR ASSY AWW1309 POWER SUPPLY UNIT AXY1168 50F DIGITAL ASSY AWW1316 PDP SERVICE ASSY 508F AWU1272 PDP-5010FD...
  • Page 18: Jigs List

    Name Jig No. Remarks Service Cotton Cloth Glove GYX1002 7.3 DISASSEMBLY AND REASSEMBLY PRECAUTIONS FOR SPEAKER SYSTEM 3.5 CLEANING Name Part No. Remarks Cleaning liquid GEM1004 Used to fan cleaning. Refer to “10.4 CHASSIS SECTION (1/2)”. Cleaning paper GED-008 PDP-5010FD...
  • Page 19 PDP-5010FD...
  • Page 20: Block Diagram

    4. BLOCK DIAGRAM 4.1 OVERALL WIRING DIAGRAM (1/2) PDP-5010FD...
  • Page 21 When ordering service parts, be sure to refer to "EXPLODED VIEWS and PARTS LIST" or "PCB PARTS LIST". mark found on some component parts indicates the importance of the safety factor of the part. Therefore, when replacing, be sure to use parts of identical designation. PDP-5010FD...
  • Page 22: Overall Wiring Diagram (2/2)

    4.2 OVERALL WIRING DIAGRAM (2/2) V+8V_AU V+3_3V_A V+3_3V_AU_D PDP-5010FD...
  • Page 23 PDP-5010FD...
  • Page 24: Overall Block Diagram (1/2)

    CLK / LE / HBLK / LBLK R/G/B R/G/B DRIVER IC DRIVER IC DRIVER IC DRIVER IC DRIVER IC DRIVER IC DRIVER IC IC1681 IC1671 IC1661 IC1651 IC1871 IC1861 IC1851 50F ADDRESS L ASSY 50F ADDRESS S ASSY A B C PDP-5010FD...
  • Page 25 CLK / LE / HBLK / LBLK R/G/B R/G/B DRIVER IC DRIVER IC DRIVER IC DRIVER IC DRIVER IC DRIVER IC DRIVER IC DRIVER IC IC1681 IC1671 IC1661 IC1651 IC1681 IC1671 IC1661 IC1651 50F ADDRESS L ASSY 50F ADDRESS L ASSY PDP-5010FD...
  • Page 26: Overall Block Diagram (2/2)

    SCL_AV I2S_BCLK_DTV I2S_LRCLK_DTV I2S_SDATA_DTV SPDIF_DTV I2S_BCLK_HDMI I2S_LRCLK_HDMI I2S_SDATA_HDMI SPDIF_HDMI TXD_SR+ RXD_SR+ SR_OUT IC8301 TXD/RXD AGC1037- RS232C 232C_DET (IF UCOM) IC9201 TAS5122DCA-TBB (D-AMP) IC7001 FHD IR ASSY TC90173FG KEY_AD1/AD2 IC6301 IC6401 SIDE KEY ASSY BCM3517 BCM7038 POD Card POD ASSY PDP-5010FD...
  • Page 27 A0 to 19 PQ200WNA1ZPH PQ200WNA1ZPH DQ0 to 15 (FAN CONTROL) (FAN CONTROL) IC8402 AGC1039- Input 4 Input 5 Input 6 Input 7 (FLASH) HDMI HDMI HDMI HDMI TRAP SW FHD FAN TRAP SW CONNECT ASSY 50 FHD LED ASSY PDP-5010FD...
  • Page 28: Power Supply Unit

    4.5 POWER SUPPLY UNIT POWER SUPPLY UNIT PDP-5010FD...
  • Page 29: X Drive Assy

    Drive Signal Gate Signal +16.5 PreDrive +16.5V SOFT-D Drive Signal PSUS RESONANCE LOGIC BLOCK BLOCK +16.5 Drive Signal OFFSET BLOCK VSUS PSUS VPOFS VPOFS VXKOFS1 VXKOFS2 OFFSET BLOCK Reg. DC/DC +16.5V CONV. VSUS BLOCK +60V +8V +3.3V +60V +8V +3.3V PDP-5010FD...
  • Page 30: Y Drive, 50F Scan A, B, C And D Assys

    BLOCK IC5V/VF VH IC5V DC/DC DC/DC BLOCK IC5V CONV. Scan IC CONV. IC3103 +3.3V VADR VH IC5V Photo Coupler Scan Signal BLOCK Scan IC IC3102 IC5V Scan IC IC3101 50F SCAN D ASSY (LOW-SIDE_LOW) 50F SCAN C ASSY (LOW-SIDE_HIGH) PDP-5010FD...
  • Page 31: Power Supply Block Of 50F X, Y Drive And 50F Scan A, B, C And D Assys

    Note: VYPRST, VSNOFS, VYKOFS12, VYKOFS3, VYKOFS4 YKOFS VYKOFS drive VXKOFS1 and VXKOFS2 voltages are electrical volume controls. Reg. YKOFS VYKOFS drive Reg. RST-D drive SOFT-G drive Scan Logic IC5V Scan IC 50F SCAN A, B, C, D ASSYS PDP-5010FD...
  • Page 32: Address L And S Assys

    DRIVER IC DRIVER IC IC1851 IC1861 IC1871 CLK / LE / HBLK / LBLK R/G/B VADR1 VDDLS1 VADR2 VDDLS2 VADR3 VDDLS3 RESONANCE RESONANCE RESONANCE BLOCK BLOCK BLOCK IC1801 LVDS Receiver V+60V V+3.3V AN/P BN/P CN/P DN/P CLKN/P CN1801 CN1802 PDP-5010FD...
  • Page 33: Digital Assy

    RST_SQ IC3601 PSIZE V+1_2V_D V+3_3V_D LVDS TRANSMITTER PEG384B IC3401 LVDS LVDS V+1_1V_D V+1_8V_D V+3_3V_D Flash Memory SUB-FILD CONV. XSUS IC3302 & RESETX XY DRV SEQUENCE UART PATTERN GEN. PEG383B-K IC3301 LVDS LVDS Reciever Reciever IC3201 IC3202 INP_MUTE V+3VACTV LVDS PDP-5010FD...
  • Page 34: Main Assy (Dtv Block Diagram)

    BCM3517 KQLGB0-K SPDIF out I2S out [IC6301] HSX_0 I2C0 SDRAM [IC6602] 256Mbit [12bit] 1Chip System IC To ARIA SDRAM BCM7038KPB1G-B2-K [IC6603] [IC6401] 256 Mbit YUV(656) [8bit] From VDEC SDRAM [IC6604] 256Mbit SDRAM [IC6605] 256 Mbit UARTA VBI_Y From AV_SW PDP-5010FD...
  • Page 35 PDP-5010FD...
  • Page 36: Power Supply Block Of Main Assy

    LTC 3407 IC4501 IC4401 DD com. 3.3V-REG for EMMA (V+2_5V_UCOM) (V+3_3V_A) V+2_5V_UCOM V+3_3V_A_ADC LTC3407-2 NJM2846DL3-33 V+2_5V_UCOM_DDR Q4416 FET Switch IC4501 (V+3_3V_A_VDEC) V+3_3V_A_VDEC DD com. RTQ040P02 for EMMA (V+1_5V_UCOM) V+1_5V_UCOM LTC3407-1 IC4404 DD com. for 7038, 3517 (V+1_2V_D) V+1_2V_D_7038 LTC3416 V+1_2V_D_3517 PDP-5010FD...
  • Page 37 FET Switch (V+2_5V_D) V+2_5V_D_7038 (V+1_8V_A_VDEC) V+1_8V_A_VDEC BD8602FV-3/ MCH3406 SP8M4 V+2_5V_D_7038_DDR V+2_5V_D_3517 Q4411 FET Switch (V+2_5V_D2) V+2_5V_D2_ARIA RSS100N03 V+2_5V_D2_ARIA_DDR Q4514 FET Switch (V+3_3V_D2) V+2_5V_UCOM_VBI RTQ040P02 IC4403 IC4106 3ch DD com. 1.5V-REG for ARIA V+1_2V_D2_ARIA (V+1_2V_D2) (V+1_5V_VDEC) V+1_5V_UCOM_VBI BD8602FV-3/ NJM2886DL3-15 RSS100N03 RSS090P03 PDP-5010FD...
  • Page 38: Tanshi Assy

    INPUT1 INPUT(VIDEO) for MAIN ASSY INPUT2 INPUT3 INPUT4 INPUT5 PC AUDIO SCL_AV INPUT3(YPbPr) DETECT SDA_AV for SIDE IO ASSY BLOCK RST_MSP SPDIF_DTV I2S_DTV INPUT3(AUDIO,CVBS) SPDIF_HDMI for SIDE IO ASSY A_NG_B for MAIN ASSY R OUT L OUT SP TERMINAL PDP-5010FD...
  • Page 39: 50Fhd Led And Fhd Ir Assys

    4.14 50FHD LED and FHD IR ASSYS PDP-5010FD...
  • Page 40: Power Supply Block Of Fhd Rls And Side Key Assys

    4.15 POWER SUPPLY BLOCK of FHD RLS and SIDE KEY ASSYS FHD RLS ASSY OP AMP V+3_3V_UCOM IC9781 MM3012XN IC9782 AMS114YD01 SIDE KEY ASSY V+3_3V_STB S9501 to S9507 PDP-5010FD...
  • Page 41: Diagnosis

    500 mS 500 mS normally. Orange Blue Downloading of DTV Module software is abnormally finished. Orange 500 mS 500 mS 500 mS 500 mS 500 mS 500 mS 500 mS Blue Always lighting Always lighting Trap switch Orange Lightins out PDP-5010FD...
  • Page 42: Power On Sequence

    2 : The IF microcomputer sends the operation data of the remote control unit (or KEY) to the main microcomputer. 3 : The main microcomputer issues a startup command (PON) to the MOD microcomputer. 4 : The relay is controlled with logical OR interpretation of control signals by the main microcomputer and module (MOD) microcomputer. PDP-5010FD...
  • Page 43: Details Of Power On Sequence

    Scan DRIVE DCDC/REG DRIVE/SCAN Sensor The user operation with the remote control unit is invalid. (All LED: OFF) Standby power device and some Vcc power devices operate. RGB-SW/AD/D-AMP/MAP are electrified, but uses the power-saving mode function of the IC. PDP-5010FD...
  • Page 44 Module_ EEPROM V+6.5V ucom V+5.1V Vsus Vadr Digital DRF_B VSUS VADR X/Y Drive Address BAK_EEP Scan ASIC ADDRESS DRIVE DCDC/REG DRIVE/SCAN Sensor A state when it displays a picture on the PDP. (Blue LED: ON) All devices are electrified. PDP-5010FD...
  • Page 45: Diagnosis Flowchart Of Failure Analysis

    Is there any local abnormality Is the abnormality associated Replace the panel chassis. with a single scan line? on the screen? with one ADDRESS or one TCP? Failure analysis for the Failure analysis for the drive system => DR3 drive system => DR4 PDP-5010FD...
  • Page 46 Is an external video signal MAIN Assy => MA3 displayed properly? Problems concerning the audio output No Failure analysis for the Is the audio signal output? audio system => AU1 Specific failure whose cause is difficult to identify in the initial stage PDP-5010FD...
  • Page 47: Power Supply Unit

    Replace the POWER SUPPLY 200 and 210 V (VSU: 125/35°C). specified range? Unit. The ripple must be within 10 V. Replace the POWER SUPPLY Is there a fluctuation in the Unit. VSUS voltage? The POWER SUPPLY Unit is normal. PDP-5010FD...
  • Page 48: Drive Assy

    Properly connect the panel FPC Replace the FFC cables. Is the input signal normal? connectors properly connected to and SCAN Assys connectors. the X/Y DRIVE Assys? Replace the panel chassis. Replace the X/Y DRIVE Assys. Replace the DIGITAL Assy. PDP-5010FD...
  • Page 49 Is the input signal normal? Replace the FFC cables. (See the oscilloscope photos.) Replace the DIGITAL Assy. Is the waveform of the control signal from the SCAN Assy normal? Replace the Y DRIVE Assy. (See the oscilloscope photos.) Replace the SCAN IC. PDP-5010FD...
  • Page 50 Are all the connectors properly Reconnect the connectors. connected? Is the TCP control signal normal? Is the input signal normal? (See the oscilloscope photos.) (See the oscilloscope photos.) Replace the panel chassis. Replace the FFC cables. Replace the DIGITAL Assy. PDP-5010FD...
  • Page 51 Is the waveform of the SCAN IC Replace the Y DRIVE Assy. control signal from the Y DRIVE Assy normal? Replace the SCAN IC. Replace the panel chassis. PDP-5010FD...
  • Page 52: Digital Assy

    Replace the MAIN Assy. Replace the MAIN Assy. Is the indication position correct? It is most likely that the sync signal is abnormal. Is the tone correct? It is most likely that the video signal data are missing. Replace the MAIN Assy. PDP-5010FD...
  • Page 53: Main Assy

    SIDE KEY and MAIN Assys. Can the unit be turned on, using Replace the MAIN Assy. Replace the MAIN Assy. RS-232C commands? Failure in the RS-232C driver and its peripheral circuits Failure in the Main microcomputer. Replace the MAIN Assy. PDP-5010FD...
  • Page 54: Video System

    Is the sync signal input to IC8001? Replace the MAIN Assy. Replace the MAIN Assy. Replace the MAIN Assy. Is the selected input signal a => USB_E / USB_R USB signal? No problem with the MAIN Assy PDP-5010FD...
  • Page 55 IC4801 - pin 22 (S-video) IC4801 - pin 26 (S-video) V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div PDP-5010FD...
  • Page 56 IC4801 - pin 22 (S-video) IC4801 - pin 26 (S-video) V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div PDP-5010FD...
  • Page 57 IC5001 - pin 48 (PC) IC5001 - pin 54 (component) IC5001 - pin 54 (PC) V: 500 mV/div H: 10 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div PDP-5010FD...
  • Page 58 IC5001 - pin 54 (component) IC5001 - pin 54 (PC) V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 10 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div V: 500 mV/div H: 20 μsec/div PDP-5010FD...
  • Page 59 Is the signal from IC6401 to Check between IC6401 and IC8001? IC8001. If there is no problem then replace IC6401. Has the symptom been settled The panel is defective. when the MAIN Assy is replaced? Replace the MAIN Assy. PDP-5010FD...
  • Page 60: Audio System

    (pins 2, 3, 5, 6) microcomputer and clock output of X9101. 49 50 If there was no ploblem replace the MAP5601M. Are signals output from IC9151? Check the IC9151 and peripheral circuit. (pins 1, 7) Repair the failure points. PDP-5010FD...
  • Page 61 V: 2 V/div H: 1 mS/div V: 2 V/div H: 1 mS/div V: 2 V/div H: 1 mS/div IC9101 - pins 38, 39 IC8871 - pins 1, 7 V: 1 V/div H: 1 mS/div V: 1 V/div H: 1 mS/div PDP-5010FD...
  • Page 62 IC5201 - pin 78 IC9101 - pin 106 IC9101 - pin 107 IC9101 - pin 108 V: 1 V/div H: 1 μS/div V: 1 V/div H: 10 μS/div V: 1 V/div H: 10 μS/div V: 1 V/div H: 10 μS/div PDP-5010FD...
  • Page 63: Diagnosis Of Pd (Power-Down)

    5.3 DIAGNOSIS OF PD (POWER-DOWN) 5.3.1 BLOCK DIAGRAM OF THE POWER-DOWN SIGNAL Block Diagram of the Power-Down Signal PDP-5010FD...
  • Page 64: Pd (Power-Down) Diagnosis Of Failure Analysis

    POWER SUPPLY Unit disconnection detection Connectors EXT_PD line: Open CN3801 disconnection detection UNKNOW DIGITAL Assy It becomes "UNKNOW" except ModuleUcom can not Each PD line of ModuleUcom above-mentioned PD detection detection condition. UVP: Under Voltage Protect , OVP: Over Voltage Protect PDP-5010FD...
  • Page 65 Y DRIVE Assy SCAN A, B, C, D 4 (SCN-5V) CN2801, CN2902 Assy SCAN A, B, C, D Assy CN3002, CN3101 CN1602, CN1802 DIGITAL Assy 8 (ADRS) ADDRESS Assy CN1601, CN1801 X DRIVE Assy, 8 (ADRS) Y DRIVE Assy PDP-5010FD...
  • Page 66 IC5V SCN5V_PD voltage detection DCDC converter drive stop SCAN Hi Unconnect SCAN Low Unconnect YDRV_PD disconnection detection Decrease voltage 15VDD detection VNOFS Decrease voltage VKOFS1_2 YDD_PD detection VKOFS3 VKOFS4 Decrease voltage VPRST detection Increase or decrease SCAN_PD voltage detection PDP-5010FD...
  • Page 67: Diagnosis Of Sd (Shutdown)

    5.4 DIAGNOSIS OF SD (SHUTDOWN) 5.4.1 BLOCK DIAGRAM OF THE SHUTDOWN SIGNAL Block Diagram of the Shutdown Signal PDP-5010FD...
  • Page 68: Sd (Shutdown) Diagnosis

    5.4.2 SD (SHUTDOWN) DIAGNOSIS PDP-5010FD...
  • Page 69 PDP-5010FD...
  • Page 70: Non-Failure Information

    In a case of color difference 4:2:2, Y, Cb, and Cr use 12 bits each, but Cb and Cr are transmitted at a half sampling rate of Y. This unit is capable of processing the upper 10 bits out of 12 bits of video data. Recent high-end DVD players, such as Pioneer DV-79AVi, are capable of outputting 10-bit color-difference signals.
  • Page 71 " Confirmation of the manufacturer of the connected equipment Check if the connected equipment was manufactured by Pioneer and if it supports the HDMI Control function. If its manufacturer is not Pioneer, proper operations are not guaranteed.
  • Page 72 • "Power On Test" or "Power Off Test" cannot be selected (the items are grayed) • The connected device cannot be turned on/off. In some cases, an operation check using another HDMI input connector may be required in order to narrow down the cause. PDP-5010FD...
  • Page 73: Function Of Decreasing The Brightness Level

    Detection example: Protection against panel cracking 80 °C. High-temperature protection function 2 The count of plasma discharge with regard to the APL will be decreased if the panel temperature becomes 55 °C or higher. APL (average picture level) PDP-5010FD...
  • Page 74: Outline Of The Operation

    (The panel drive-power OFF state remains in effect even if the main power switch is set to OFF after that command is sent.) When the panel drive-power is ON When the panel drive-power is OFF POWER SUPPLY Unit POWER SUPPLY Unit DRF-SW-B (TEST PIN) DRF-SW-B (TEST PIN) Alligator clip Multi base Multi base PDP-5010FD...
  • Page 75: Specification Of The Fan Control

    • When the temperature rises, the sensor voltage of TEMP2 decreases. • When the voltage of the DAC output for external FAN decreases, rotation speed of FAN rises. PDP-5010FD...
  • Page 76: Processing In Abnormality

    When the panel is off: A warning indication is not displayed immediately but is displayed when the panel is turned on. Note: A warning indication is displayed each time the panel is turned on if the conditions for a shutdown persist. Conditions for resetting the circuits The circuits will be reset upon Standby ON/OFF. PDP-5010FD...
  • Page 77 A specific LED flash pattern (blue LED, 13 times) starts. The next PON operation is valid, and the flag is cleared upon the next power-on. If RST4 is H, a restoration process starts according to the latest power-on/-off status. PDP-5010FD...
  • Page 78 UART. Upon receiving the data, the main microcomputer orders a specific LED flash pattern (blue LED, 4 times). The next PON operation is valid, and the flag is cleared upon the next power-on. PDP-5010FD...
  • Page 79: Trap Switch

    (1) Deactivating with the remote control unit • Enter Factory mode. • Proceed to the INITIALIZE layer of Factory mode. Hold the DISPLAY key pressed for more than 5 seconds. (2) Deactivating with the RS-232C command • Send the CTM (cancel) command. PDP-5010FD...
  • Page 80: Service Factory Mode

    How to exit Service Factory Mode By using a PDP service remote control) • PDP service remote control : press [FACTORY] key. • Supplied remote control unit : press [HOME MENU] key. By issuing RS-232C commands) • Issue [FAN]. PDP-5010FD...
  • Page 81: Functions When Entering The Service Factory Mode

    (HDMI settings, etc.). • Data on screen (i.e., screen position; meaning clock dividers, and not including data on screen size). Are reset to the default values (data stored in memory will be retained). Screen size will be retained. PDP-5010FD...
  • Page 82: Remote Control Code In Service Factory Mode

    (Note 1) When ten seconds have passed since the [DRIVE OFF] key was pressed at the standby, it becomes invalid. Please press [POWER] key from the [DRIVE OFF] key pressing within ten seconds when you do power supply ON while driven OFF. PDP service PRO-1150HD PDP-5010FD remote control PRO-950HD PDP-5010FD...
  • Page 83: Pdp Service Remote Control

    Press this key to turn on the unit. This key cannot turn the unit off. POWER OFF Press this key to turn off the unit. This key cannot turn the unit on. POINT ZOOM Not used with this model. ZOOM +/- Not used with this model. PDP-5010FD...
  • Page 84: Factory Hierarchical Table

    ADDRESS U3 <=> PH0 to PH9 Equivalent to AP3S*- (Setting value: PH2) ADDRESS U4 <=> PH0 to PH9 Equivalent to AP3S-* (Setting value: PH1) STK MODE <=> OFF <=> MODE1 to MODE8 <=> SKM S00 to S07 *: Setting value PDP-5010FD...
  • Page 85 6.2.4.1 SIDE MASK LEVEL (+) SIDE MASK LEVEL <=> 6.2.4.2 FINAL SETUP DATA RESET <=> NO <=> YES 6.2.4.3 HMG/HG SERVICE MODE MODE SHIFT <=> NO <=> YES Exclusively used for 6.2.4.4 Wide XGA AUTO <=> technical analysis DISABLE <=> ENABLE (details omitted) PDP-5010FD...
  • Page 86: Indications In Service Factory Mode

    2 SIG mode and Screen size Note: See SIG-Mode Tables. (See next page.) 3 Color system and Signal type Color System and Signal Type NTSC Composite input S-connector input Y/CB/CR Y/PB/PR Digital Video signal Option (Destination, Panel Generation, etc.) Options Regular model ELITE model PDP-5010FD...
  • Page 87 Current selection of the screen size 5th Character GUI Notation VIDEO Remarks k (∗) − DOT BY DOT FULL − ZOOM − CINEMA − WIDE k: supported, −: unsupported Note (∗): It is effective only with models having the Full HD panel. PDP-5010FD...
  • Page 88: Details Of Factory Menu

    In the 19-24 rows, the version of the execution program is displayed. • PANEL INFO: It displays the generation of the panel, inchage and the type of the panel. For details on display values and settings, see "10: Panel Information" in "9.3.1. QS1 (PANEL STATUS)." PDP-5010FD...
  • Page 89 0 6 0 – D I G – R S I 0 1 2 3 4 5 6 7 O R D 1 2 3 4 Display Example Meaning Item Name HMG/HG module Version HMG/HG 01234567 User Password PASSWORD 1234 PDP-5010FD...
  • Page 90 Abnormally in RST2 of MAIN Assy. (power decrease of DC-DC converter) RELAY Abnormally in RST4 of MAIN Assy. (power decrease of Relay power) Failure at Home Media Gallery Home Media Gallery startup error MA-EEP IIC communication line between EEPROM and MAIN. PDP-5010FD...
  • Page 91 Even if [k] key or [l] key is pressed, {CLEAR <=> :YES} ⇔ {CLEAR <=> :NO} is repeated. If the [ENTER/SET] key is kept on pressing for 5 second when the status of this menu is <YES>, clear process will begin. PDP-5010FD...
  • Page 92 B-SENSOR : The value that indicated the degree of brightness input into an Room light sensor is displayed. AD value when the output of the Room light sensor was input into 89 pin (AN5) of IF uCOM is displayed. PDP-5010FD...
  • Page 93 Even if [k] key or [l] key is pressed, {CLEAR <=> :YES} ⇔ {CLEAR <=> :NO} is repeated. If the [ENTER/SET] key is kept on pressing for 5 second when the status of this menu is <YES>, clear process will begin. MTB HOUR METER is cleared only. PANEL HOUR METER is not cleared. PDP-5010FD...
  • Page 94 HDMI mode status ---- BIST NVAL N value CTSVAL CTS value AKSV Shadow AKSV value BKSV Shadow BKSV value IT CNT IT content (AVI info) EXTCOL Extension calorimetry (AVI info) RGV QR RGB range (AVI info) PIXDEP Number of pixel/bit PDP-5010FD...
  • Page 95 2200 562 or 563 1920 1920x1080i @ 60 720p (750p) @ 60 1650 1280 1280x720p @ 60 1080p (1125p) @ 60 2200 1125 1920 1080 1920x1080p @ 60 1080p (1125p) @ 24 2750 1125 1920 1080 1920x1080p @ 24 PDP-5010FD...
  • Page 96 Displays signal status that is input to VDEC. Sub Address Sub Address Device Meaning (Main screen) (Sub screen) 205h 605h CC detection 1 208h 608h CC detection 2 VDEC 20Bh 60Bh CC-CRI detection 20Ch 60Ch XDS content advisor 0 20Dh 60Dh XDS content advisor 1 PDP-5010FD...
  • Page 97 E R R O R E R R O R 6.2.1.14 DTV TV-GUIDE BER Exclusively used for production line. TV-Guide error bit ratio information is displayed. 6.2.1.15 DEBUG INFO Exclusively used for technical analysis. Debug information for development use is displayed. PDP-5010FD...
  • Page 98: Panel Factory (+)

    RASTER MASK SETUP (+) The mask indication (RASTER) can be set and indicated. 6.2.2.10 PATTERN MASK SETUP (+) The mask indication (PATTERN) can be set and indicated. 6.2.2.11 COMBI MASK SETUP (+) The mask indication (COMBI) can be set and indicated. PDP-5010FD...
  • Page 99 • P-COUNT: The accumulated power-on count is indicated. • TEMP1: The current panel temperature and the historical maximum temperature recorded in memory are indicated. The range of temperature indication is from -50.0 to +99.9. (The temperature unit is " °C (Centigrade) ".) PDP-5010FD...
  • Page 100 MAIN EEPROM Communication Error MDU-IIC MD-IIC BACKUP BACKUP EEPROM Communication Error DAC1 DAC1 Communication Error DAC2 DAC2 Communication Error − − Abnormally in RST2 power supply RST2 High temperature of the panel TEMP-H Panel temperature TMP-NG Low temperature of the panel TEMP-L PDP-5010FD...
  • Page 101 <VOL+> : Adding by 10 to the adjustment/ setting value <VOL-> : Subtracting by 10 from the adjustment/setting value F S E < = > <SET> : Determining the adjustment/setting value and shifting to the upper layer PDP-5010FD...
  • Page 102 The number of the adjustment table and the drive sequence currently selected are displayed on the right side of the third line as the On-Screen display. Drive sequence and adjustment table Sequence Name Video50 Video60 Video72 Video75 PC60 Adjustment Value TBL2 TBL1 TBL1 TBL3 TBL4 Table PDP-5010FD...
  • Page 103 : Shifting to the previous item <RIGHT> : Adding by one to the adjustment/ setting value <LEFT> : Subtracting by one from the adjustment/setting value <SET> : Determining the adjustment/setting value and shifting to the upper layer – < = > PDP-5010FD...
  • Page 104 : Shifting to the previous item <RIGHT> : Adding by one to the adjustment/ setting value <LEFT> : Subtracting by one from the adjustment/setting value <SET> : Determining the adjustment/setting value and shifting to the upper layer < = > O P R T PDP-5010FD...
  • Page 105 M A S K • The MASK indication sequence can be changed among 48V, 50V, 60V, 72V, 75V and 60P using the Right or Left key. The selected sequence and the ABL/WB table are retained until the mask is turned off. PDP-5010FD...
  • Page 106 M A S K • The MASK indication sequence can be changed among 48V, 50V, 60V, 72V, 75V and 60P using the Right or Left key. The selected sequence and the ABL/WB table are retained until the mask is turned off. PDP-5010FD...
  • Page 107 M A S K • The MASK indication sequence can be changed among 48V, 50V, 60V, 72V, 75V and 60P using the Right or Left key. The selected sequence and the ABL/WB table are retained until the mask is turned off. PDP-5010FD...
  • Page 108: Option

    Exclusively used for production line. 6.2.3.2 ANTENNA MODE <=> Exclusively used for production line. 6.2.3.3 AFT <=> Exclusively used for production line. 6.2.3.4 SYNC DET (+) Exclusively used for technical analysis (details omitted). 6.2.3.5 CC (+) Exclusively used for technical analysis (details omitted). PDP-5010FD...
  • Page 109: Initialize

    • When the configuration is set to <YES> and the [ENTER/SET] key is pressed for 5 seconds, the reset action executes. Be sure to disconnect and connect the AC cable after FINAL SETUP. When replacing the MAIN Assy, the FINAL SETUP is required. PDP-5010FD...
  • Page 110 Be sure to do above procedure at input fuction except HMG. For details, refer to the service manual for the ELITE model. HG (Home Gallery) SERVICE MODE (Regular model) 1. Home Gallery Screen (1) When the USB device is connected (2) When the USB device is not connected PDP-5010FD...
  • Page 111 6 S (String descriptor info - 2) Product String 7 S (String descriptor info - 3) String SerialNumber 2. End method It is the same as the case that Home Gallery displays. 6.2.4.4 Wide XGA AUTO <=> Exclusively used for technical analsyis (details omitted). PDP-5010FD...
  • Page 112: Disassembly

    (50U) Multi base Terminal panel A Front Chassis HT (508F) Assy, Section Front Chassis HB Assy (50), Panel holder V1 (50), V2 (50), Front chassis VL (508F) PANEL TANSHI DIGITAL SENSOR SCAN A SCAN B SCAN C SCAN D PDP-5010FD...
  • Page 113: Disassembly

    Disconnect the speaker cables. Remove the three screws. Remove the speaker system. Remove the three brackets by removing the six screws. Speaker cable ×2 Bracket When using the Pioneer table top stand Speaker system ×2 Bracket ×2 Speaker cable Bracket ×2 Bracket Speaker system ×2...
  • Page 114 Remove the rear case (508F). Tightening sequence for the screws when assembling When assembling the rear case (508F), tighten the screws in the following sequence: Tighten the two screws. Tighten three screws. Tighten the two screws. Tighten the eight screws. Tighten other screws. PDP-5010FD...
  • Page 115 When removing the POWER SUPPLY Unit, be sure to remove POWER SUPPLY not only the POWER SUPPLY Unit Unit but entire PCB base. PCB base Styling of jumper wires around the FAN motor 50F Y DRIVE POWER SUPPLY Assy Unit PDP-5010FD...
  • Page 116 Upon servicing, be sure to restore the original wiring of the unit after repair work. Tightening sequence for the screws when assembling When assembling the terminal panel B (50U), tighten the screws in the following sequence: Tighten the screw. Tighten the screw. Tighten other screws. PDP-5010FD...
  • Page 117 Remove the Front case Assy (508FU), by pulling it upward. Rivet Front side Turn it not to press the rivet. When assembling the front case, (Because when the rivet presses, fit in once again.) tighten this rivet first. PDP-5010FD...
  • Page 118 Access to 50F DIGITAL Assy Disconnect the cable. Multi base section Remove the two screws. Remove the four screws. Lift the Multi base section to the direction of the arrow. Multi base section Multi base section PANEL SENSOR Assy 50F DIGITAL Assy PDP-5010FD...
  • Page 119 FHD IR Assy FHD RLS Assy 50FHD LED Assy Panel holder V1 (50), V2 (50) Remove the two screws. Unhook the six hooks. Remove the panel holders V1 (50) and V2 (50). Panel holder V2 (50) Panel holder V1 (50) PDP-5010FD...
  • Page 120 50F SCAN D Assy Assy Assy Assy Notes for Three pieces connector 40P* Three pieces connector 40P is a precision part. Pay attention to the handling. Connecting Method Disconnecting Method In addition, please do not touch the electrode plane. PDP-5010FD...
  • Page 121: Disassembly And Reassembly Precautions For Speaker System

    Note: Be careful not to bend the Grille Assy too far. When reassembling the cabinet and the baffle plate, secure the Otherwise, it may be damaged. screws in the order shown in the figure below: OK: Good example NG: Bad example Grille Assy Front Baffle Grille Assy Baffle Rear PDP-5010FD...
  • Page 122: Each Setting And Adjustment

    3. Select “Channel Setup”. ( then ENTER) 4. Select “POD ID”. ( • The Host ID and Cable Card ID appear. 5. Press HOME MENU to exit the menu. (*) : When replacing the MAIN Assy, be sure to perform the FINAL SETUP. PDP-5010FD...
  • Page 123 “8.5 ADJUSTMENTS WHEN THE DRIVE ASSYS ARE REPLACED. No adjustment required ADDRESS Assy No adjustment is required after replacement of parts PANEL SENSOR Assy other than those mentioned above. No adjustment required TANSHI Assy PDP-5010FD...
  • Page 124: Backup Of The Eeprom (Digital Assy)

    1 Turn on the unit, using the remote control unit or by issuing the PON command. Then issue the FAY command. 2 Issue the BCP command to transfer the data stored in the EEPROM for backup. 3 Turn the power off. PDP-5010FD...
  • Page 125 1 Turn on the unit, using the remote control unit or by issuing the PON command. Then issue the FAY command. 2 Issue the UAJ command to delete data stored in the EEPROM on the DIGITAL Assy. 3 Issue the BCP command to transfer the data stored in the EEPROM for backup. 4 Turn the power off. PDP-5010FD...
  • Page 126 When a DIGITAL Assy with an EEPROM in which adjustment data are stored is mounted, this step is not required after manual adjustment. ("DIGITAL EEPROM: REPAIR" is not indicated.) (2) Method using the RS-232C commands Issue the FAJ command. PDP-5010FD...
  • Page 127: How To Clear History Data

    P COUNT INFO. < = > : NO OPRT P COUNT INFO. < = > : CLEAR Right SET (5 sec) MAX TEMP. < = > : NO OPRT Right MAX TEMP. < = > : CLEAR SET (5 sec) 3 Turn the power off. PDP-5010FD...
  • Page 128: Adjustment When The Service Panel Assy Is Replaced

    [DIZ S03] : Dither ON, L dither ON, noise OFF. [$1800000001] : LUT mode ON [$1000003F00] : Reset active control OFF. ∗: If the unit is shut down during the above adjustment flow, resend the above commands from the beginning. PDP-5010FD...
  • Page 129 (RST MASK 22: Cyan 3SF) Checking VOL YNOFS3/4/1 (min) (RST MASK 16: Green 1023+) Replacement with the parts for service Checking VOL YNOFS3/4/1 (min) • Re-replacement of the panel (RST MASK 15: Red 1023+) • Replacement of the DRIVE Assy PDP-5010FD...
  • Page 130 : To set the gamma G value to that for Factory mode [PGB S00] : To set the gamma B value to that for Factory mode [DIZ S03] : Dither ON, L dither ON, noise OFF. [$1800000001] : LUT mode ON [$1000003F00] : Reset active control OFF. PDP-5010FD...
  • Page 131 (Check on the PANEL 1-ADJ menu.) Return VOL OFFSET to the tentative setting value. / [VOF ∗∗∗] Determine the tentative setting value for VOL OFFSET as the final value. From the Recovery flowchart (1-2) and (1-4) [To the Main flowchart (2)] PDP-5010FD...
  • Page 132 Determine the tentative setting value for VOL YNOFS4 as the final value. *1: The tentative setting value becomes the final value. Determine the tentative setting value for VOL YNOFS1 as the final value. From the Recovery flowchart (2-1) and (2-3) [Adjustment completed] PDP-5010FD...
  • Page 133 Display RST MASK 02 (Red). / [MKS S52] Set VOL OFFSET to the current setting value plus 112. / [VOF ***] Replacement of abnormal circuits or Is there erroneous discharge (abnormal dead cell)? re-replacement of the panel required (Check on the PANEL 1-ADJ menu.) PDP-5010FD...
  • Page 134 (dead cell). The VOL OFFSET value must be 117 or greater. Replacement of abnormal circuits or Current VOL OFFSET < 117? re-replacement of the panel required Display RST MASK 03 (Green). / [MKS S53] [To the Recovery flowchart (1-4)] PDP-5010FD...
  • Page 135 (Check on the PANEL 1-ADJ menu.) Set VOL OFFSET to the current setting value plus 64. / [VOF ***] Determine the current VOL OFFSET setting value as the final value. [To the Main flowchart (2)] PDP-5010FD...
  • Page 136 Set VOL YNOFS3 to the current setting value +47. / [VY3 ***] Set VOL YNOFS4 to the current setting value +47. / [VY4 ***] Replacement of abnormal circuits or Is there erroneous discharge (abnormal lit cell)? re-replacement of the panel required (Check on the PANEL 1-ADJ menu.) PDP-5010FD...
  • Page 137 Set VOL YNOFS4 to the current setting value plus 4. / [VY4 ∗∗∗] Replacement of abnormal circuits or Current VOL YNOFS3 setting value > 137? re-replacement of the panel required Is there erroneous discharge (abnormal dead cell)? [To the Recovery flowchart (2-1)] PDP-5010FD...
  • Page 138 Make a note of this VOL YNOFS3 value. Set VOL YNOFS1 to the final setting value of VOL YNOFS3 minus 31. / [VY1 ***] Determine the current VOL YNOFS1 setting value as the final value. [To the Main flowchart (2)] PDP-5010FD...
  • Page 139 Setting Voltages Vysnofs (V) Vyprst (V) Vyknofs1,2 (V) Vyknofs3 (V) Vyknofs4 (V) PDP-5010FD...
  • Page 140 Setting Voltages Vyprst (V) Vyknofs1,2 (V) Vyknofs3 (V) Vyknofs4 (V) Vyprst (V) PDP-5010FD...
  • Page 141: Adjustment When The Drive Assys Are Replaced

    Adjust so that "Δ Tsus - gub = Δ Tsus - iub + α ± 5 nsec," using the variable controls shown in the table below: Value of α Assy X DRIVE Assy VR1002 70 nsec Y DRIVE Assy VR2002 60 nsec PDP-5010FD...
  • Page 142 (input to the gate terminal of Q2111) SUS-D pulse width: Tsus - Dg Adjust so that "Tsus - Dg = Tsus - D ± 5 nsec," using the variable control shown in the table below: Assy Y DRIVE Assy VR2001 PDP-5010FD...
  • Page 143 2 Adjust the pulse width (Tsus - Dg) of the SUS-D Y DRIVE Assy input signal so that it becomes "Tsus-D ± 5 nsec." 1 Measure the SUS-D pulse width (Tsus - D). TP2114 from VR2001 IC2104 DIGITAL Assy Q2111 IC2005_A7 Q2105 IGBT YSUS-D Q2113 IGBT TP2116 PDP-5010FD...
  • Page 144: Precaution On Replacement Of The Power Supply Unit

    Disconnect the housing wire (J126) from the P11 terminal Connect the housing wire (J126) to the P11 terminal on the old POWER SUPPLY Unit. on the new POWER SUPPLY Unit. Housing wire (J126) Housing wire (J126) POWER SUPPLY unit (old) POWER SUPPLY unit (new) PDP-5010FD...
  • Page 145: Rs-232C

    9.1.2 USING RS-232C COMMANDS Individual ports are provided for RS-232C and SR+ connectors with this model. Therefore, unlike the case of previous models, which required switching of exclusive operation between these connectors on the Integrator menu, switching is no longer required. PDP-5010FD...
  • Page 146: List Of Rs-232C Commands

    Dither/L dither ON & noise ON Dither/L dither OFF & noise ON Dither/L dither ON & noise OFF Panel drive-power OFF Panel drive-power ON To subtract ∗∗∗ to the adjustment value (∗∗∗ = 000 to 999, designated by a function command) PDP-5010FD...
  • Page 147 Green vertical line scroll Green horizontal line scroll Vertical ramp vertical scroll (white) Vertical ramp vertical scroll (green) Horizontal ramp horizontal scroll (white) Horizontal ramp horizontal scroll (green) Cross hatch + window MASK OFF H ramp (slant 1) H ramp (slant 4) PDP-5010FD...
  • Page 148 For panel light check 1 For panel light check 2 5 for perfect linear 6 for perfect linear 7 for perfect linear 8 for perfect linear Mask for ABL adjustment Raster - White Raster - Red Raster - Green PDP-5010FD...
  • Page 149 Panel drive mode (STANDARD) Panel drive mode (DYNAMIC) Panel drive mode (MOVIE) Panel drive mode (GAME) Panel drive mode (SPORTS) Panel drive mode (PURE) Panel drive mode (USER) Panel drive mode (ISF-DAY) Panel drive mode (ISF-NIGHT) Panel drive mode (OPTIMUM PDP-5010FD...
  • Page 150 Green-independent gamma setting: Fixed on 2.2 (default) Green-independent gamma setting: Fixed on 2.3 Green-independent gamma setting: Fixed on 2.4 S10-31 Green-independent gamma setting: Customize ∗∗∗ Panel white balance adjustment - Green highlight ∗∗∗ Panel white balance adjustment - Green low light PDP-5010FD...
  • Page 151 Each information output for panel Acquiring unit data, such as the software version common to all models, regardless of destination Acquiring data on shutdown Acquiring data related with signals Acquiring the software sub-version of the microcomputer at panel side PDP-5010FD...
  • Page 152 Measures against AM radio noise - SUS FREQUENCY MODE 5 Measures against AM radio noise - SUS FREQUENCY MODE 6 Measures against AM radio noise - SUS FREQUENCY MODE 7 Measures against AM radio noise - SUS FREQUENCY MODE 8 PDP-5010FD...
  • Page 153 Theater port interlock operation OFF Theater port interlock operation ON Determining the flag for the DIGITAL Assy adjustment in "not adjusted" To add ∗∗∗ to the adjustment value (∗∗∗ = 000 to 999, designated by a UP∗ function command) PDP-5010FD...
  • Page 154 3SF and later-YSUS Tail (resonance down width) UP*/DN* is not effective ∗∗∗ 2SF-repeat YSUS (resonance up width) UP*/DN* is not effective Initializing the video EEPROM data Initializing the setting data to which no adjustment command is provided PANEL EEPROM REFLESH PDP-5010FD...
  • Page 155: Details Of Each Commands

    2: Panel Generation 8th byte 2nd PLANT (XGA 50 inch only) System model 1st PLANT (XGA 50 inch only) All-in-one design TV PLANT information and SQ_LSI version ∗ Monitor mismatching (version mismatching at SD) Standard module ‘ Others Simple module PDP-5010FD...
  • Page 156: Qs2 (Panel Operation Data)

    X-DRV Adjustment not MASK-OFF completed X-DCDC MASK-ON X-SUS DIG-DCDC 14 to 17: Detection of Each Protection function 3: Adjustment-data Not used Normal operation backup flag Not used At detection of protection operation With backup data UNKNOWN No backup data PDP-5010FD...
  • Page 157: Qs3 (Other Data On The Panel)

    PON COUNTER 8 byte 00000000 Note TEMP1 acquisition (Temperature value) 5 byte +25.0 (*1) (*1) : Centigrade scale TEMP0 acquisition (Temperature value) 5 byte +25.0 (*1) MaxTEMP acquisition (Temperature value) 5 byte +75.0 (*1) ∗∗∗∗ Reserved 4 byte 2 byte PDP-5010FD...
  • Page 158: Qaj (Panel Adjustment Data)

    ADDRESS 1, 2 setting value 2 byte ADDRESS 3, 4 setting value 2 byte ADDRESS 5, 6 setting value 2 byte ADDRESS 7, 8 setting value 2 byte Streaking correction 1 byte AM radio countermeasure 1 byte ∗∗ Reserved 2 byte 2 byte PDP-5010FD...
  • Page 159: Qpw (Video Adjustment Data Of The Panel)

    QPM (fixed) Pulse meter B 1 8 byte 00000000 Pulse meter B 2 8 byte 00000000 Pulse meter B 3 8 byte 00000000 Pulse meter B 4 8 byte 00000000 Pulse meter B 5 8 byte 00000000 2 byte PDP-5010FD...
  • Page 160: Qpd (Pd Logs)

    Data from the hour meter for the seventh latest PD 8 byte 00000213 Eighth latest "1st PD" data 1 byte Eighth latest "2nd PD" data 1 byte Data from the hour meter for the eighth latest PD 8 byte 00000123 2 byte PDP-5010FD...
  • Page 161: Qsd (Sd Logs)

    Data from the hour meter for the seventh latest SD 8 byte 00000000 TEMP1 (high temperature) Eighth latest SD data 1 byte TEMP1 (low temperature) Eighth latest SD subcategory data 1 byte Data from the hour meter for the eighth latest SD 8 byte 00000000 2 Byte PDP-5010FD...
  • Page 162: Qse (Destination Peculiar Information)

    3 byte A/D value of MTB-side Temperature 3 byte MTB-side FAN rotating speed (0: STOP, 1: LOW, 2: HIGH) 1 byte A/D value of room light sensor 3 byte Level of room light sensor (Value: 1 to 5) 1 byte PDP-5010FD...
  • Page 163: Qng (Shutdown Information Of Mtb)

    Failure of Power Supply at MTB side Go to No. 13 Subcategory Information 14(E) Startup failure of Home Media Gallery 15(F) Failure of Main EEPROM Immediately Shutdown ∗: Indicates the frequency of Blue LED flashing when the shutdown is occurred. PDP-5010FD...
  • Page 164 Shutdown Home Gallery AD/PLL Shutdown Middleware HDMI Shutdown Application Tuner 2 Shutdown US-MSP Shutdown < No. 13 Subcategory Information on "Failure in Power supply at MTB side" > Value Shutdown Factor Remarks (Operation) RST 2 Shutdown RST 4 Shutdown PDP-5010FD...
  • Page 165: Qsi (Input Signal Data)

    Once the DRIVE OFF command is accepted, DRIVE OFF cannot be canceled by pressing the DRIVE OFF key again or by turning the unit off then back on with the STANDBY OFF/ON key. To cancel DRIVE OFF, restart the unit by unplugging then again plugging in the power cord. PDP-5010FD...
  • Page 166: Fay / Fan (Adj. Commands Permission / Prohibition)

    To make the flag setting that indicating that adjustment of the main [UAJ] unit has not been completed During FAY To make the flag setting that indicating that backup data have not The backup ROM is [CBU] been copied initialized. To copy Digital backup data to EEPROM [BCP] PDP-5010FD...
  • Page 167 PDP-5010FD...
  • Page 168: Exploded Views And Parts List

    For the applying amount of lubricants or glue, follow the instructions in this manual. (In the case of no amount instructions, apply as you think it appropriate.) 10.1 PACKING SECTION Screw ×2 Speed clamp ×3 Bead band ×3 Plastic Band ×2 PDP-5010FD...
  • Page 169 Parental Caution See Contrast table (2) Polyethylene Bag See Contrast table (2) Power Button Caution See Contrast table (2) (2) CONTRAST TABLE PDP-5010FD/KUCXC and KUC are constructed the same except for the following: PDP-5010FD PDP-5010FD Mark Symbol and Description /KUCXC /KUC...
  • Page 170: Rear Section

    10.2 REAR SECTION MAIN CN4109 MAIN CN4110 (USB) CN8801 CN8802 TANSHI Refer to "10.3 FRONT SECTION". PDP-5010FD...
  • Page 171 See Contrast table (2) Screw TBZ40P080FTB Label A (U) AAX3478 Screw BBZ30P060FTB Screw BPZ30P100FTB (2) CONTRAST TABLE PDP-5010FD/KUCXC and KUC are constructed the same except for the following: PDP-5010FD PDP-5010FD Mark Symbol and Description /KUCXC /KUC 5 Function Button Base ANG3066 ANG2923...
  • Page 172: Front Section

    10.3 FRONT SECTION Refer to "10.4 CHASSIS SECTION (1/2)". MAIN CN4107 MAIN CN4109 Rear view PDP-5010FD...
  • Page 173 Blind Cushion (508F) AEB1479 Nylon Rivet AEC1671 Rivet AEC1877 1..Front Case Assy (508FU) AMB3001 NSP 9 2..Panel Cushion H (50) AED1257 NSP 10 2..Panel Cushion V (50) AED1258 • • • • • FC Gate Sheet AMR3746 Screw ABZ30P080FTC PDP-5010FD...
  • Page 174: Chassis Section (1/2)

    10.4 CHASSIS SECTION (1/2) Refer to "10.7 MULTI BASE SECTION". Cleaning liquid : GEM1004 Cleaning paper : GED-008 FHD FAN CONNECT CN9555 FHD FAN CONNECT FHD FAN CN9553 CONNECT CN9554 MAIN CN4103 Refer to POWER "10.5 CHASSIS SECTION (2/2)". SUPPLY PDP-5010FD...
  • Page 175 Screw PPZ50P100FTB Multi Base Holder ANG2937 Screw TBZ40P080FTB Screw ABA1364 (2) CONTRAST TABLE PDP-5010FD/KUCXC and KUC are constructed the same except for the following: PDP-5010FD PDP-5010FD Mark Symbol and Description /KUCXC /KUC 8 Sub Frame L Assy 507 ANA2080 ANA1945...
  • Page 176: Chassis Section (2/2)

    10.5 CHASSIS SECTION (2/2) MAIN CN4101 MAIN CN4105 MAIN TANSHI CN4106 CN8806 AC Inlet POWER SW CN9571 MAIN CN4113 Fan×3 Refer to "10.6 PANEL CHASSIS SECTION". PDP-5010FD...
  • Page 177 ADX3550 8P&8P Housing Wire (J102) ADX3551 14P Housing Wire (J104) ADX3553 6P&6P Housing Wire (J108) ADX3556 (2) CONTRAST TABLE PDP-5010FD/KUCXC and KUC are constructed the same except for the following: PDP-5010FD PDP-5010FD Mark Symbol and Description /KUCXC /KUC 45 Screw...
  • Page 178: Panel Chassis Section

    10.6 PANEL CHASSIS SECTION PDP-5010FD...
  • Page 179 Screw ABA1364 Three Pieces Connector 40P AKM1384 Gasket AD ANK1948 Screw See Contrast table (2) (2) CONTRAST TABLE PDP-5010FD/KUCXC and KUC are constructed the same except for the following: PDP-5010FD PDP-5010FD Mark Symbol and Description /KUCXC /KUC 20 Screw ABA1313...
  • Page 180: Multi Base Section

    10.7 MULTI BASE SECTION 50FHD LED CN9671 SIDE KEY CN9501 FHD IR CN9731 50F DIGITAL CN3201 FHD RLS CN9781 POWER (side) FHD FAN CONNECT CN9551 POWER POWER SIDE IO CN9352 SIDE IO CN9351 PDP-5010FD...
  • Page 181 Terminal Panel A (U) ANC2440 POD Stay A ANG2933 • • • • • Gasket UD ANK1883 Hex. Head Screw BBA1051 Washer Faced Nut BBN1005 Screw BMZ30P060FTB Screw PMB30P080FNI 6P Housing Wire (J115) ADX3561 4P Housing Wire (J122) ADX3564 PDP-5010FD...
  • Page 182: Pdp Service Assy 508F (Awu1272)

    10.8 PDP SERVICE ASSY 508F (AWU1272) Exterior Section PDP-5010FD...
  • Page 183 AEC2122 Protect Sheet AHG1331 Gasket ADH-FCH ANK1850 Gasket AD ANK1948 NSP 18 Front Case (508F) AMB3000 Rear Case (508F) ANE1662 NSP 20 Drive Voltage Label ARW1097 Screw (3 x 40P) ABA1332 Screw ABA1351 Screw ABA1364 Screw ABZ30P080FTC Screw AMZ30P060FTB PDP-5010FD...
  • Page 184: Table Top Stand

    Rear Bottom view TABLE TOP STAND PARTS LIST Mark No. Description Part No. Base Cover Assy AXY1176 Stand Pipe L Assy AXY1182 Stand Pipe R Assy AXY1183 Screw ABA1357 Screw (M8 x 23) ABA1371 Screw (M8 x 40) ABA1373 PDP-5010FD...
  • Page 185: Speaker System (Packing)

    SHL1450 2..Gasket SED1138 Polyethylen Bag S0 SHL1451 2..Gasket SED1166 NSP 11 2..Bracket LR SNA1481 NSP 27 CS Assy SMW1987 NSP 28 Serial Label SRW1112 1..Bracket Assy (C) SXG1128 2..Gasket SED1140 2..Gasket SED1141 2..Gasket SED1167 NSP 16 2..Bracket C SNA1482 PDP-5010FD...
  • Page 186: Cs Assy

    10.11 CS ASSY Tweeter Input Terminal Input Terminal PDP-5010FD...
  • Page 187 NSP 36 Acoustic Absorbent SMT1328 NSP 37 Acoustic Absorbent SMT1357 NSP 38 Acoustic Absorbent SMT1358 NSP 39 Acoustic Absorbent SMT1359 NSP 40 Model Label SAN3955 NSP 41 Caution Label SRR1024 NSP 42 Serial Label SRW1111 • • • • • PDP-5010FD...

Table of Contents