This chapter contains a selection of alarms, error messages and troubleshooting information.
Self-test POST
During booting, the BIOS first performs a Power On Self-Test or POST. This checks to
ensure that certain device components are functioning properly. The boot sequence is
interrupted immediately if critical errors occur.
If the POST does not find an error, the BIOS initializes and tests further components. The
graphics are already initialized in this phase of booting. Any error messages that occur are
displayed on the screen.
Error diagnostics
The following describes the error message from the system BIOS.
Note
For information on error messages output by the operating system or programs, refer to the
corresponding manuals.
Error
Display remains dark
A beep sounds when a key is
pressed but no character is
displayed.
COM 1 or LPT 1 port does not
respond.
Mouse pointer no longer
moves.
Panel PC IL 77
Operating Instructions, Edition 10/2004, A5E00339979-01
Cause
Power supply not connected
properly
Keyboard buffer is full.
The port is deactivated in BIOS
Setup.
The PS/2 port is deactivated in
BIOS Setup.
11
Remedy
Check the power outlet, power
cable and plug.
<CTRL> <PAUSE> keys
Activate the COM 1 or LPT 1 port
in the submenu "Hardware
Options".
Check the Setup setting.