Fantech 150H-EC Installation And Operation Manual

Fantech 150H-EC Installation And Operation Manual

Fresh air appliance (hrv)
Table of Contents

Advertisement

Available languages

Available languages

HERO SERIES
Fresh Air Appliance (HRV)
PARTS IN THE BOX
Heat Recovery Ventilator, 1 pc
Hanging Bracket, 1 pc
Drain Hose Kit, 1 pc
Operation and Installation Manual, 1 pc
Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of
such requirements, with the current edition of the National Building Code, and / or ASHRAE's "Good Engineering Practices".
REGISTER THIS PRODUCT TO
BE REMINDED OF SUGGESTED
PRODUCT CARE SCHEDULE
registration.fantech.app
United States
800.747.1762
Canada
800.565.3548
Fantech reserves the right to modify, at any time and without notice, any or all of its products' features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
Installation and Operation Manual
Item #: 428486
Rev Date: 2020-01-23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 150H-EC and is the answer not in the manual?

Questions and answers

Summary of Contents for Fantech 150H-EC

  • Page 1 Canada 800.565.3548 Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position. Please visit our website www.fantech.net for more detailed technical information.
  • Page 2 Note Warning/ Information Technical Practical tip Important information note PLEASE READ AND SAVE THESE INSTRUCTIONS For residential use only Before installation careful consideration must be given to how this system will operate if connected to any other piece of mechanical equipment, i.e., a forced air furnace or air handler operating at a higher static pressure.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INSTALLATION TYPES HRV ducting for fully Dedicated System ........... . 4 HRV/Furnace ducting for Partially Dedicated System.
  • Page 4: Installation Types

    • Mini split heat pump procedure found in the section “AIRFLOW * In the case of a multi-zone system, please BALANCING.” contact Fantech customer service prior to Benefits: installing any installation type requiring the use * In the case of a multi-zone system, please...
  • Page 5: Installing The Outdoor Vents

    INSTALLING THE OUTDOOR VENTS RECOMMENDED INSTALLATION Intake • Should be located upstream of prevailing winds from exhaust • At a minimum of 900 mm (3') away from dryer vents and furnace exhaust (medium (900 mm) or high efficiency furnaces), driveways, oil 36"...
  • Page 6: Duct Installation

    DUCT INSTALLATION CONNECTING THE DUCTS TO THE HRV EXHAUST TO FRESH OUTDOOR STALE AIR FRESH AIR OUTDOOR HOOD AIR INTAKE • Ducts should be kept short and have as FROM HOME TO HOME few bends or elbows as possible. • 45º elbows are preferable to 90º. •...
  • Page 7: Mounting Options

    MOUNTING OPTIONS WALL MOUTING BRACKET INSTALLATION LOCATION • Must be located in a conditioned space Safety screws where it will be possible to conveniently (included) service the unit. • Typically located close to the outside wall where the hoods will be mounted. •...
  • Page 8: Wall Controls

    WALL CONTROLS * Please see instruction manuals for individual controls for proper wiring and set up of control systems. CENTRAL CONTROLS These control options can only be used individually Ensure that unit is not CONTROLS FEATURES CONNECT TO plugged when connecting ECO-Touch®...
  • Page 9: Balancing

    BALANCING Balancing must be completed using the Fantech ECO-Touch ® Programmable Touch Screen Wall Control Supply manometer High High ENTERING BALANCING MODE Exhaust In the options menu during manometer the initial 5 second countdown sequence, long press on "ECO" area for 5 seconds to enter basic balancing mode.
  • Page 10: Wiring Diagram

    WIRING DIAGRAM - HERO 120H, 150H, 200H...
  • Page 11 WIRING DIAGRAM - HERO 150H-EC, 250H-EC (CONT'D)
  • Page 12 WIRING DIAGRAM (CONT'D) WIRING DIAGRAM TO Standard Accessory Control Contact Standard Furnace Interlock Wiring FURNACE THERMOSTAT TERMINALS FOUR WIRE TWO WIRE heating only FOR A FURNACE CONNECTION TO A COOLING SYSTEM: On some newer furnaces and older FURNACE thermostats, energizing the R and 24-VOLT TERMINAL BLOCK G terminal at the furnace has the...
  • Page 13: Troubleshooting

    TROUBLESHOOTING Problem Causes Solutions Air is too dry Dehumidistat control is set too low Increase the desired level of humidity. Change ventilation mode from continuous mode to standby. HRV out of balance Have contractor balance HRV airflows Air is too humid Dehumidistat control is set too high Reduce the desired level of humidity.
  • Page 14: Filter Location

    Merv 8 Filter the serial number will be used for the beginning of the warranty period. • The fans found in all Fantech HRVs require no lubrication, and are factory balanced to prevent vibration Electrostatic and promote silent operation.
  • Page 15: Parts List

    PARTS LIST HERO 120H HERO 150H HERO 200H HERO 150H-EC HERO 250H-EC BOM # Description (99400) (99401) (99402) (463253) (463254) MOTOR 428469 428515 428516 428517 428518 CELL 414708 414709 414710 414709 414710 MERV1 (pack of 2) 428519 428520 428521 428520...
  • Page 16 NOTES...
  • Page 17 Canada 800.565.3548 Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position. Please visit our website www.fantech.net for more detailed technical information.
  • Page 18 Remarque Avertissement/ Information Information Conseil pratique Remarque technique importante VEUILLEZ LIRE ET CONSERVER CES INSTRUCTIONS. Pour utilisation résidentielle seulement. Avant l’installation, il faut étudier soigneusement comment ce système fonctionnera s’il est relié à une autre pièce d’équipement mécanique, comme une chaudière à air pulsé ou un appareil de traitement de l’air fonctionnant à une pression statique plus élevée.
  • Page 19 TABLE DES MATIÈRES TYPES D’INSTALLATION Conduits de VRC pour un système entièrement spécialisé ........20 Conduits de VRC/chaudière pour un système partiellement spécialisé...
  • Page 20: Types D'installation

    Centre d’assistance à la Assure la meilleure distribution d’air frais dans la maison et offre le coût d’utilisation le clientèle de Fantech avant toute installation clientèle de Fantech avant toute installation nécessitant l’utilisation d’un dispositif de nécessitant l’utilisation d’un dispositif de plus faible, car un appareil de traitement de verrouillage de chaudière.
  • Page 21: Installation Des Évents Extérieurs

    INSTALLATION DES ÉVENTS EXTÉRIEURS INSTALLATION RECOMMANDÉE Admission • Doivent être situés en amont des vents dominants de l’échappement. • Distance minimale de 900 mm (3 pi) des évents de la sécheuse et de l’échappement de 900 mm la chaudière (chaudières à efficacité moyenne (3 pi) min.
  • Page 22: Installation Des Conduits

    INSTALLATION DES CONDUITS RELIER LES CONDUITS AU VRC ÉVACUATION VERS ADMISSION D’AIR AIR VICIÉ AIR FRAIS L'EXTÉRIEUR FRAIS EXTÉRIEUR • Les conduits doivent être courts et DE LA MAISON VERS LA MAISON présenter le moins de plis ou coudes possibles. •...
  • Page 23: Options De Fixation

    OPTIONS DE FIXATION INSTALLATION À L’AIDE DES SUPPORTS MURAUX EMPLACEMENT • L’appareil doit être situé dans un endroit conditionné où il sera pratique de Vis de sécurité l’entretenir. (incluses) • On le place habituellement près du mur extérieur où les chapeaux de protection seront installés.
  • Page 24: Commandes Murales

    COMMANDES MURALES * Veuillez consulter les manuels d’instructions des dispositifs de commande individuels pour connaître la bonne configuration de câblage et l’installation adéquate des systèmes de commande. COMMANDES CENTRALES Assurez-vous que l’appareil Ces commandes peuvent uniquement être utilisées individuellement n’est pas branché lorsque COMMANDES CARACTÉRISTIQUES RELIER À...
  • Page 25: Équilibrage

    ÉQUILIBRAGE L’équilibrage doit être réalisé à l’aide de la commande murale à écran tactile programmable Fantech ECO-Touch MD . Manomètre d’alimentation Élevé Élevé ACCÉDER AU MODE D’ÉQUILIBRAGE Faible Faible Manomètre Dans le menu d’options, lors de la d’évacuation séquence de décompte initiale de 5 secondes, appuyez sur la zone...
  • Page 26: Schéma De Câblage

    SCHÉMA DE CÂBLAGE - HERO 120H, 150H, 200H...
  • Page 27 SCHÉMA DE CÂBLAGE - HERO 150H-EC, 250H-EC (SUITE)
  • Page 28 SCHÉMA DE CÂBLAGE (SUITE) SCHÉMA DE CÂBLAGE Contact de commande d’accessoire standard Fil de verrouillage de chaudière alternatif VERS LA CHAUDIÈRE BORNES DE THERMOSTAT QUATRE FILS DEUX FILS chauffage DISPOSITIF DE VERROUILLAGE seulement POUR RELIER UNE CHAUDIÈRE À UN SYSTÈME DE REFROIDISSEMENT : Sur certaines nouvelles chaudières et BLOC DE JONCTION...
  • Page 29: Dépannage

    DÉPANNAGE Problème Causes Solutions L’air est trop sec. Le réglage du déshumidistat est trop faible. Augmentez le taux d’humidité souhaité. Changez le mode de ventilation de continu à en attente. Le VRC est déséquilibré. Demandez à un entrepreneur d’équilibrer les débits d’air du VRC. L’air est trop humide.
  • Page 30: Emplacement Du Filtre

    établir la période de la garantie. • Les ventilateurs dans tous les VRC Filtres de Fantech ne nécessitent aucune lubrification, et ils sont équilibrés électrostatiques en usine afin de prévenir les vibrations et favoriser un fonctionnement silencieux.
  • Page 31: Liste De Pièces

    LISTE DE PIÈCES HERO 120H HERO 150H HERO 200H HERO 150H-EC HERO 250H-EC BOM # Description (99400) (99401) (99402) (463253) (463254) MOTOR 428469 428515 428516 428517 428518 CELL 414708 414709 414710 414709 414710 MERV1 (pack of 2) 428519 428520 428521...
  • Page 32 Fantech reserves the right to make technical changes. Fantech se réserve le droit d’apporter des modifications For updated documentation please refer to www.fantech.net techniques. Pour de la documentation à jour, veuillez consulter le site www.fantech.net. Fantech MD...

This manual is also suitable for:

Hero series250h-ec

Table of Contents

Save PDF