Table of Contents
loading
Need help?

Need help?

Do you have a question about the 31 P and is the answer not in the manual?

Questions and answers

Summary of Contents for Atmos 31 P

  • Page 1 MedizinTechnik English ATMOS ® Chair 31 P 503.0800.B 503.0802.B 2015-08 Index: 09...
  • Page 2: Table Of Contents

    Installation and start-up ........7-8 Operating elements ............. 7 Electrical connection ........... 7 Fixing the ATMOS Chair 31 P ........7 ® Mounting the foot rest ..........8 Fixation of the back rest ..........8 Adjusting the head rest ..........8 Removing the head rest ..........
  • Page 3: Introduction

    ● The declaration of conformity and our general standard terms and conditions can be obtained on our website at www.atmosmed.com ● The quality management system applied at ATMOS has been certifi ed according to international standards EN ISO 9001 and EN ISO 13485.
  • Page 4: Function

    ® comfortable deportment for the patient (seating or half-lying position) at optimum examination position. ● The ATMOS Chair 31 P is equipped with a mechanical ® height adjustment. The seat height can be varied between 48 - 68 cm. ● The upper part of the chair is rotatable by 360° and can be arrested in every height and rotary position by a fi...
  • Page 5: Scope Of Supply

    Introduction Scope of supply Prior to dispatch, this ATMOS device was subjected to an extensive functional test and has been carefully packed. Nevertheless, please compare the contents of the shipment on completeness immediately upon receipt (see delivery note) Transport and storage ●...
  • Page 6: For Your Safety

    ATMOS liable for personal injury and damage to property if ● The ATMOS Chair 31 P may only be operated in rooms ® • original ATMOS parts are not being used, used for medical purposes, but not in areas subject to •...
  • Page 7: Installation And Start-Up

    Operating elements Electrical connection  Head rest ● The ATMOS Chair 31 P is supplied with a power cable ®  and connection for non-heating appliances. The power Lever for adjusting the backrest cable is inserted in the socket for non-heating ...
  • Page 8: Mounting The Foot Rest

    Installation and start-up Mounting the foot rest (option) First of all press the collar bushings (503.0735.0) from inside, on the left and right, into the front drillings of the seat base frame. Afterwards bring the upper part of the pre-assembled component (with the fold-away foot plate in front) in correct position between the two bushings.
  • Page 9: Operation

    Operation Positioning the patient Ensure that your patients sit in the middle of the seat. A constant unilateral strain on the seat can damage the surface Adjusting the seat height The swivel joint must be arrested (multifunctional lever in uppermost position = swivel locking) in all ...
  • Page 10: Adjusting The Fold-Away Foot Rest

    Operation Adjusting the fold-away foot rest (option) Movement of the foot rest is synchronised with the movement of the back rest. Fig 9. ATMOS Chair 31 P in half-lying position ®...
  • Page 11: Cleaning And Care

    5.2 Cleaning the unit's surfaces and upholstery ● The surfaces of the ATMOS Chair 31 P are resistant against all the recommended surface disinfectants stated in chapter ® 5.3 and 5.4. Nevertheless after any length of time discolourations could possibly develop.
  • Page 12: Maintenance And Service

    ATMOS for use with these chairs. 7.0 Troubleshooting The ATMOS Chair 31 P was subjected to a close quality examination before leaving the factory. If, however, any problems ® should occur please contact an ATMOS service technician. error indication...
  • Page 13: Options, Accessories And Spare Parts

    8.0 Options, accessories and spare parts Options Description Foot rest, rigid....................503.0731.0 made of silver-coloured metal tube and hard rubber Foot rest, fold-away ..................503.0810.0 moves synchronously when tilting the back rest Accessories Child seat..................... 503.0372.0 made of tearproof imitation leather for long durability, height: 9 cm, colour: white...
  • Page 14: Spare Parts

    8.0 Options, Accessories and spare parts Spare parts Backrest complete, white/dove-blue ............503.0712.0 Backrest complete, basic/dove-blue ............503.0713.0 Cylinder head screw, inner edge 8x20 ............051.0087.0 Washer 8.4 form-b ..................053.0012.0 Seat cushion, white ................... 503.0714.0 Seat cushion, basic ................... 503.0715.0 Cylinder head screw, inner edge 6x45 ............
  • Page 15: Technical Data

    Technical data Voltage 100-230 V~ ± 10 % 50/60 Hz Current input max. 2,5 A @ 100 V~ max. 1,1 A @ 230 V~ Power cable 3 m long Power consumption max. 250 VA Operating time continuous operation: 3 minutes max. Height adjustment electrically driven lift column, operation by foot switch...
  • Page 16: Testing / Disposal

    Checking / Disposal 10.1 Checking ATMOS devices The ATMOS devices are maintenance-free when they are used according to the operating instructions. Regular, thoroughly cleaning and disinfection of the application parts respectively the operation in line with the operating instructions are assumed.
  • Page 17: Notes On Emc

    11.1 Guidelines and Manufacturer´s Declaration - Emissions The ATMOS Chair 31 P is intended for use in the electromagnetic environment specifi ed below. The customer or ® user of the ATMOS Chair 31 P should ensure that it is used in such an environment.
  • Page 18 11.3 Guidelines and Manufacturer´s Declaration - Electromagnetic interference The ATMOS Chair 31 P is intended for use in the electromagnetic environment specifi ed below. The customer or ® user of the ATMOS Chair 31 P should ensure that it is used in such an environment.
  • Page 19: Notes On Emc

    ATMOS Chair 31 P ® The ATMOS Chair 31 P is intended for use in an electromagnetic environment in which ratiated disturbances ® are controlled. The customer or user of the ATMOS Chair 31 P can help prevent electromagnetic interference ®...