Chapter 10
Alarm Monitoring and Management
Table 10-2 Color Codes for Alarms, Conditions, and Events
Color
Red
Orange
Yellow
Magenta
Blue
White
10.2.1 Controlling Alarm Display
You can control the display of the alarms on the Alarms tab.
perform from the Alarms tab.
Table 10-3 Alarm Display
Button
Synchronize Alarms
Delete Cleared Alarms
AutoDelete Cleared
Alarms
Show Events (NA)
10.2.2 Viewing Alarm-Affected Circuits
User can view which ONS 15327 circuits are affected by a specific alarm. To do this, highlight an alarm
and right-click it. The Selected Affected Circuits shortcut menu appears.
Select Affected Circuits option. When the option is clicked, the affected circuits are shown as in
Figure
June 2002
Description
Critical Alarm (CR)
Major Alarm (MJ)
Minor Alarm (MN)
Event (NA)
Condition (NR)
Cleared alarm or event (CL)
Action
Updates the alarm display; although CTC displays alarms in real time, the
Synchronize Alarms button allows you to verify the alarm display. This is
particularly useful during provisioning or troubleshooting.
Deletes alarms that have been cleared.
If checked, CTC automatically deletes cleared alarms.
If checked, CTC shows alarms and NA events or conditions. Not-alarmed
events do not require action and normally are displayed only under the
Conditions tab.
10-3.
Viewing ONS 15327 Alarms
Table 10-3
shows the actions you can
Figure 10-2
Cisco ONS 15327 User Documentation, R3.3
illustrates the
10-3