Sub-base/module connector/
mounting bracket PAML-...-90
Operating instructions
Translation of the original instructions
For all available product documentation è www.festo.com/pk
Sub-base/module connector/mounting bracket PAML-...-90
1
Application
The connecting plates PAML-CP are intended to serve exclusively as adapters for
the pneumatic connection and for tube fastening for in-line installation of service
units. The module connector PAML-MK connects two service units with each other.
The mounting brackets PAML-MB are used for connection and wall mounting of
individual devices or service units.
• The product may only be used in its original status without unauthorised modi­
fications. Only the assembly and commissioning activities described in these
operating instructions are permissible.
• Observe the permissible limit values and specifications.
• Only use the product if it is in an excellent technical status.
• Take into consideration the legal regulations applicable for the location as well as:
– Regulations and standards,
– Regulations of the testing organisations and insurers,
– National specifications.
2
Installation
Note
• Installation should only be conducted by qualified personnel.
Warning
Risk of injury from falling loads.
• Take the weight of an individual device or a service unit into consideration.
Dependent on the design, a mounted service unit can weigh more than 50 kg.
• Only mount the individual device or service unit on a wall or mounting frame
that can support its weight.
• Only mount the individual device or service unit on a flat surface.
Definition
Front plate = front module connector
Rear plate = rear module connector
2.1 Assembly of two service units of the same size with module connector
PAML-MK
• Note the flow direction from 1 to 2.
The numerals on the product housing 1 serve as orientation.
1
Fig. 1
1. First, push both mounting screws through both holes of the front plate 3.
2. Place the seal 4 between the service units.
3. Place the front and rear plate 3 and 2 into the slots of the service units.
4. Turn the screws of the front plate 3 into the rear plate 2.
2.2 Mounting the connecting plates PAML-CP
Size G¼ ... G1 (Fig. 2)
• Make sure that the sealing groove, which exists in only one of the two connect­
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
1. Insert the O-rings 5 into the designated O-ring grooves.
Germany
+49 711 347-0
2. Place the connecting plates in position.
3. Fasten the connecting plates with the appropriate 4 screws M8 6 and washers
www.festo.com
4. Secure the screw connection with a screw locking agent, e.g. Loctite 243.
8082032
5. Observe the max. screw-in depth for the pipe connector, è Fig. 4.
2017-11a
[8082035]
. . . . . . . . . . .
English
Fig. 2
Size G1¼ (Fig. 3)
• Make sure that the sealing groove, which exists in only one of the two connect­
1. Insert the O-rings 9 into the designated O-ring grooves.
2. Place the connecting plates in position.
3. Place the front and rear plate 8 and 7 into the slots of the service units.
4. Turn the screws of the front plate 8 into the rear plate 7.
5. Observe the max. screw-in depth for the pipe connector, è Fig. 4.
Fig. 3
2
Fig. 4
3
10 Nm
4
ing plates, lines up with the flat surface on the housing. If mounted correctly,
the stamp number on the connecting plate will be the same as the stamp num­
ber on the housing (1 or 2).
to the service unit.
12 Nm
ing plates, lines up with the flat surface on the housing. If mounted correctly,
the stamp number on the connecting plate will be the same as the stamp num­
ber on the housing (1 or 2).
Product type
ISO 228
Connecting plate PAML-CP
G1
G1¼
6
12 Nm
5
7
8
10 Nm
9
Max. screw-in depth
[mm]
12
14
16
18
20

Advertisement

loading
Need help?

Need help?

Do you have a question about the PAML-90 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Festo PAML-90 Series

  • Page 1 5. Observe the max. screw-in depth for the pipe connector, è Fig. 4. Translation of the original instructions 2017-11a [8082035] 12 Nm For all available product documentation è www.festo.com/pk Sub-base/module connector/mounting bracket PAML-...-90 ... English Application...
  • Page 2 According to EC Pressure Equipment Directive positions. The standard grid width between the wall brackets is 90 mm, and the dis­ tance in height between holes is 145 mm. 1) Declaration of Conformity è www.festo.com/sp All retaining screws aC must point upwards. Fig. 6 Note The grid width for the filter PFML-90 is 135 mm and deviates from the standard.

This manual is also suitable for:

Paml-mbPaml-mkPaml-cp