ZIGBEE CERTIFICATION
Certification by the ZigBee Alliance is pending.
NETWORK SETUP
In order for the ZBDMI to become fully operational, all connections must be properly made according to the wiring diagram, and the
electronic limits of the motor must first be set. Please refer to the respective motor instructions on how to set the electronic limits.
Identifying the ZBDMI into a Network
1.
Upon power-up, the INCLUSION LED will turn on for five (5) seconds then turn off. When
the LED turns off, press and release the SETUP button a few times to verify that the motor
moves. This will indicate a good electrical connection between the ZBDMI and the motor.
2.
Select the IDENTIFYcommand on your ZigBee controller.
3.
Press and hold the SETUP button for five (5) seconds to identify the ZBDMI in the network.
Verify that the INCLUSION LED turns on within 10-15 seconds. When the LED is on,
the ZBDMI is identified in the network.
NOTE: If inclusion is unsuccessful, reset the interface according to the factory reset
instructions on the following page and try again.
Disconnecting the ZBDMI from a Network
1.
Select the DISCONNECT command on your ZigBee controller.
2.
The ZBDMI will be disconnected from the network when the INCLUSION LED turns off.
3.
To manually disconnect the ZBDMI from the network, press and hold the SETUP button for five (5) seconds. The ZBDMI will be
disconnected from the network when the INCLUSION LED turns off.
OPERATION BY CONTROLLER
The ZBDMI interface can be operated by 3rd party automation, hand-held and PC based controllers, or manually by pressing the
SETUP button. The following convention is used when operating from either 3rd party automation or controllers:
Light ON = Window Covering UP.
Light OFF = Window Covering DOWN.
Light DIM & BRIGHTEN = Window Covering OPEN at a percentage where 0% = Window Covering CLOSED at its lower limit,
and 100% = Window Covering OPEN at its upper limit.
Lighting percentage values between 0% and 100% = 99 intermediate window covering positions.
MANUAL OPERATION
The SETUP button can be used to manually operate the motor at any time as follows:
Repeatedly pressing and releasing the SETUP button within ½ second will drive the motor in a sequence of UP-STOP-DOWN-STOP.
For example, while the motor is at rest, press and release the SETUP button to drive the motor up. Press and release the SETUP
button again to STOP the motor. Pressing and releasing the SETUP button once more will drive the motor DOWN, and a subsequent
press and release will STOP the motor.
Need help?
Do you have a question about the ZigBee and is the answer not in the manual?
Questions and answers