Contents Controller user guide ................................5 1.1. Control panel ..................................5 1.2. Main screen ................................... 6 1.3. Active components ................................6 1.4. Mode ...................................... 7 1.5. Operation program ................................8 1.6. Heat pump status ................................... 8 1.7. List of user menus ................................10 1.8.
Technical service manual ecoGEO 1. Controller user guide The information included below corresponds to application versions launched after January 2016. Other versions, both earlier and later, may differ slightly from the contents found in this section. NOTE There might be screens or screen contents that are not shown, depending on the heat pump model and the settings configured by the technical service.
Technical service manualecoGEO 1.2. Main screen The main screen of the application contains a series of fields with information about heat pump operation. Date and time // Fri 4:5 Status Energy meter 7 5 Operation program Operation mode Active components Figure 1.2.
Technical service manual ecoGEO 1.4. Mode This field shows the icons that indicate the operating modes that are active. Several operating modes can be viewed simultaneously, depending on the heat pump model and the configuration set up by the technical service. DIRECT HEATING Mode / DIRECT COOLING Mode The heat pump sends hot / cold water directly to the heating / cooling system and adjusts the power supply to the consumption of the home.
Technical service manualecoGEO Apart from the icons that define the operating modes, the following icons can also be found in this field. Operation This indicates thermal energy transfer between circuits. If the icon is shown continuously, this indicates normal heat pump operation. If the icon flashes, there is a heat pump protection activated.
Page 9
Technical service manual ecoGEO ON + NIGHT SCHEDULE status The heat pump is on and available to activate all its functions, but performance is limited by night-time schedule programming. OFF status from control panel The heat pump is switched off from the front panel of the controller and is therefore not available to activate any of its functions.
Technical service manualecoGEO 1.7. List of user menus Follow the instructions below to browse through the various user menus. Each menu has a series of screens that are used to change heat pump STATUS and OPERATION MODE, adjust comfort parameters and view desired information.
Page 11
Technical service manual ecoGEO // Fri 4:5 7 5 4:5 User menu /8 On/Off Schedule Heating User menu /8 On/Off Schedule Heating User menu Schedule Heating ooling User menu XXXXXX XXXXXX Heating XXXXXX ooling DHW/Legionella prot User menu efrigeracin DHW/Legionella prot Pool User menu /8...
Technical service manualecoGEO 1.8. Parameter adjustment Take the following steps to change a parameter: Search for the screen containing the parameter that needs adjusting (see Section 1.7). With the cursor in position 1 press on to enter the screen and move the cursor to the parameter in position 2. Adjust the parameter in position 2 using buttons Press to accept and move the cursor to position 3.
Technical service manual ecoGEO 1.10. CALENDAR Menu User menu /8 On/Off Schedule Heating /8 Date/Time Date/Time Day: Sunday This is used to adjust the day of the week, date (DD/MM/YY) and time (HH:MM 24-hour format) of the controller. Date: //5 Time: 7:5 Daily saving time...
Technical service manualecoGEO Heating groups Heating units - + - + This can be used to adjust the heating target outlet temperatures programmed by the DG: SG: 5 technical service. Each ramp increases or decreases the outlet temperature by 2°C. SG3: SG4: oom terminals...
Technical service manual ecoGEO oom terminals Interior terminals SetT Used to show and adjust the inside environment temperature setpoint (Tcons) and the DG: SG: comfort temperature differential (DTc) of the terminals of each outlet unit. SG3: ...
Technical service manualecoGEO 1.14. POOL Menu User menu /8 DHW/Legionella prot Pool Information /8 Pool Pool Enable: Used to enable the POOL mode. In versions for ecoGEO B and ecoGEO C, it can be used to adjust the percentage of Winter program Minutes per hour: ...
Page 17
Technical service manual ecoGEO oom terminals Interior terminals SetT ealT H In installations with interior terminals equipped with bus communication (Th-T or TH T: 5 498 3 T: 45 4 sensors), it displays the interior setpoint temperature (Tcons), the current temperature 45...
Technical service manualecoGEO Version Version Version: 5B Date: //5 This shows information about the application installed in the controller. Bios: 4 5//4 Boot: 45 4//3 Version firmw: 5 Firware version: 1.16. ALARMS Menu Press for quick access to the information menu from the main screen. User menu Pool Information...
Technical service manual ecoGEO 2. Controller Technical Service Guide To access the installer menu, press at the same time. Afterwards, enter access password PW1. This menu is used to define the type of installation and the services the heat pump will deal with, to adjust the various operation parameters and protections as well as to carry out various start-up and maintenance operations.
Technical service manualecoGEO 2.2. Selecting the heat pump model Installer menu / / onfiguration /7 ahange language aHeat pump model bonfiguration bSources cManual test cServices setup /7 Heat pump model Model selection Select model: 1. Used to select the heat pump model within the ecoGEO range. This selection is required for the correct operation of the heat pump and the energy counters.
Technical service manual ecoGEO Hybrid system Hybrid system Sources %min air: % 1. Used to adjust the minimum power percentage absorbed by each collector. If the %min ground: % +5% power percentage absorbed by one of the collectors decreases below the established Geothermal protection limit, it is disabled.
Page 22
Technical service manualecoGEO Heating bus terminals Heating bus terminals Type Address 1. Used to enable the use of indoor terminals with data bus communication in heating DG: th-Tune AD SG: th-Tune AD mode. SG3: th-Tune 2. Shows the address assigned (ADx) by the controller to the indoor terminal associated SG4: th-Tune SG5: th-Tune to each outlet unit.
Technical service manual ecoGEO Special parameters Special parameters DTheating: 5 1. Used to adjust the target temperature difference between the production circuit DTsupply: outlet and inlet in heating mode. 2. Used to adjust a temperature difference between the calculated target outlet Simultaneous consum...
Page 24
Technical service manualecoGEO ooling groups Cooling units DG: 1. Used to enable the outlet units in cooling mode. SG: Direct -Vdc SG3: everse -Vdc 2. Used to invert the modulating valve control logic of the combined outlet units. SG4: Direct -Vdc Note: The modulating valve control logic must be the same in both heating and cooling.
Page 25
Technical service manual ecoGEO Interior compensation Indoor offset Used to adjust the indoor offset factor for each outlet unit. The indoor offset factor DG: SG: corrects the target outlet temperature based on the indoor temperature. SG3: 0: No indoor temperature offset. SG4: ...
Technical service manualecoGEO 2.6. Configuration of the DHW production service Installer menu / onfiguration Services setup 3/ ahange language bSources booling bonfiguration cServices setup cDHW cManual test dAuxiliary systems dPool 3/ Enable: 1. Used to enable the DHW production service. 2.
Technical service manual ecoGEO 2.8. Configuration of production priorities Installer menu / onfiguration Services setup 5/ ahange language bSources dPool bonfiguration cServices setup ePriorities cManual test dAuxiliary systems fSpecial programs 5/ Priorities Priorities 1. Allows the response to the different services to be prioritised. Services with the same priority level can be dealt with simultaneously.
Page 28
Technical service manualecoGEO Installer menu / onfiguration Equipos auxiliares /3 ahange language cServices setut aBivalent parameters bonfiguration dAuxiliary systems bInternal elec heater cManual test eemote control cBoiler Internal elec heater 1. Used to enable the indoor auxiliary resistor for heating, DHW and/or pool services. In Enable: the USER level, its use must be enabled as SUPPORT and/or EMERGENCY for the DHW:...
Technical service manual ecoGEO 2.11. Configuration of remote control options Installer menu / onfiguration ahange language dAuxiliary system bonfiguration eemote control cManual test fProtections EVU signal EVU remote control Enable: 1. Used to enable the EVU electrical consumption control. The EVU control prevents production of energy with the compressor or the auxiliary equipment.
Technical service manualecoGEO BMS ONFIG BMS2 configuration ADDESS: 1. Used to assign the controller BMS2 port address. POTOOL: MODBUS MASTE BAUDATE: 4 2. Used to configure the communication parameters via the BMS2 port. STOP BIT: Note: This port can be used to connect indoor bus terminals with MODBUS MASTER PAITY: None configuration.
Technical service manual ecoGEO ompressor delay Compressor delay Delay: min 1. Used to adjust the duration of the compressor switched on delay. 5bar Note: The compressor switched on may experience extra delays due to automatic pre-start checks. Trial period Trial period Enable: 2.
Technical service manualecoGEO 2.16. Default values Installer menu 5/ dAlarm log eDefault values fhange password 5/ Initialization Initialization Delete user settings 1. Used to delete the settings in the USER and INSTALLER menus and restore default and set default factory settings. values: Energy meters Delete counters...
Technical service manual ecoGEO 3.2. Power circuit diagram ecoGEO B|C. All models. 230 Vac 24 Vac Distribution Distribution PCOOEM PCOe PCOe Fuse information 0.5Amps 2.5Amps Manufacturer SIBA SIBA TRAFO Model 70-007-33/0.5A 70-007-33/2.5A Control Supply 230 Vac Fuse rating [A] 230/24 Voltage [V] Size [mm] 5x20...
Technical service manualecoGEO 3.3. Electrical connection tables ANALOGUE INPUTS CONNECTIONS DESCRIPTION Connection terminal Controller terminal Type Signal Block I / AI1 pCOOEM+ / J2 / U1 NTC 10K 25°C Compressor suction temperature Block I / AI2 pCOOEM+ / J2 / U2 Radiometer 0-5Vdc Compressor suction pressure Block I / AI3...
Page 43
Technical service manual ecoGEO DIGITAL OUTPUTS CONNECTIONS DESCRIPTION Connection terminal Controller terminal Type Signal Block III / DO1 pCOOEM+ / J16 / NO1-NC1 Activation 230Vac / 1A max Passive cooling production Block III / DO2 pCOOEM+ / J27 / NO9-NC9 Activation 230Vac / 2A max Pool production pCOOEM+ / J27 / NO10-...
Technical service manualecoGEO 3.4. Operation map ecoGEO B|C 1-9 kW / ecoGEO B|C 3-12 kW / ecoGEO B|C 5-22 kW -7; 65 35; 65 -25; 40 -25; 10 -25; 10 35; 10 Brine / Cooling outlet temperature (ºC) Maximun speed of compressor is not able in all the areas of the operation map. NOTE...
Technical service manualecoGEO 3.9. Technical data table ecoGEO ecoGEO ecoGEO ecoGEO Specification ecoGEO B/C 1-9 Units B/C1 B/C2 B/C3 B/C4 Place of installation Indoors Type of brine system Geothermal / Aerothermic / Hybrid ✓ ✓ ✓ ✓ Heating Application ✓ ✓...
Page 55
Technical service manual ecoGEO ecoGEO ecoGEO ecoGEO ecoGEO Specification ecoGEO B/C 3-12 Units B/C1 B/C2 B/C3 B/C4 Place of installation Indoors Type of brine system Geothermal / Aerothermic / Hybrid ✓ ✓ ✓ ✓ Heating Application ✓ ✓ ✓ ✓ HTR - High temperature recovery system ✓...
Page 56
Technical service manualecoGEO ecoGEO ecoGEO ecoGEO ecoGEO Specification ecoGEO B/C 5-22 Units B/C1 B/C2 B/C3 B/C4 Place of installation Indoors Type of brine system Geothermal / Aerothermic / Hybrid ✓ ✓ ✓ ✓ Heating Application ✓ ✓ ✓ ✓ HTR - High temperature recovery system ✓...
Technical service manualecoGEO 4.7. Technical data table Specification ecoGEO HP1 12-40 kW / HP3 12-40 kW Units HP1 12-40 HP3 12-40 Place of installation Indoors Type of brine system Geothermal Heating, DHW with external storage tank and ✓ Application pool ✓...
Page 69
Technical service manual ecoGEO Specification ecoGEO HP1 15-70 kW / HP3 15-70 kW Units HP1 15-70 HP3 15-70 Place of installation Indoors Type of brine system Geothermal Heating, DHW with external storage tank and ✓ Application pool ✓ Integrated active cooling ✓...
Page 70
Technical service manualecoGEO Specification ecoGEO HP1 25-100 kW / HP3 25-100 kW Units HP1 25-100 HP3 25-100 Place of installation Indoors Type of brine system Geothermal Heating, DHW with external storage tank and ✓ Application pool ✓ Integrated active cooling ✓...
Page 72
ECOFOREST GEOTERMIA, S.L. Parque Empresarial Porto do Molle l Rúa das Pontes, 25 l 36350 – Nigrán – Pontevedra.- (Spain) Tlfs.: +34 986 262 184 / +34 986 417 700 Fax: +34 986 262 186 e-mail: Info@ecoforest.es http://www.ecoforest.es The manufacturer reserves the right to make any necessary changes to the contents of this manual without prior notice.
Need help?
Do you have a question about the ecoGEO Basic and is the answer not in the manual?