Issue 2013-08-13
Product Description
FBG132-FTL EnOcean System Gateway
Application
EnOcean system gateway for direct integration of up to 32
radio partners into the DDC4000 automation system for
building automation and control.
The system gateway supports the non-proprietary EnOcean
radio protocol.
It transmits the wireless data straight to the communication
structure of the DDC4000 automation system and the
building management system.
Content
Important Information Regarding Product Safety ..................................................................................................2
Item........................................................................................................................................................................3
Technical Data.....................................................................................................................................................3
Dimensions ..........................................................................................................................................................3
Connection...........................................................................................................................................................4
Wireless Interface ..................................................................................................................................................4
Installation..............................................................................................................................................................6
General radio installation instructions..................................................................................................................6
CAN bus installation notes...................................................................................................................................7
Mounting ................................................................................................................................................................7
Removal.................................................................................................................................................................7
Settings and LED displays.....................................................................................................................................8
Commissioning ......................................................................................................................................................9
Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen
voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения -
A változtatások jogát fenntartjuk - 保留未经通知而改动的权力
Kieback&Peter GmbH & Co. KG
Tempelhofer Weg 50, 12347 Berlin/Germany
Telefon: +49 30 60095-0, Telefax: +49 30 60095-164
www.kieback-peter.de, info@kieback-peter.com
Datasheet 2.50-40.132-01-EN
FBG132-FTL EnOcean System Gateway
A
Page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FBG132-FTL and is the answer not in the manual?

Questions and answers

Summary of Contents for Kieback&Peter FBG132-FTL

  • Page 1: Table Of Contents

    Issue 2013-08-13 Datasheet 2.50-40.132-01-EN Product Description FBG132-FTL EnOcean System Gateway FBG132-FTL EnOcean System Gateway Application EnOcean system gateway for direct integration of up to 32 radio partners into the DDC4000 automation system for building automation and control. The system gateway supports the non-proprietary EnOcean radio protocol.
  • Page 2: Important Information Regarding Product Safety

    Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "FBG132-FTL". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer.
  • Page 3: Item

    Issue 2013-08-13 Datasheet 2.50-40.132-01-EN Product Description FBG132-FTL EnOcean System Gateway Item FBG132-FTL EnOcean system gateway for direct integration of up to 32 technoLink® field devices, en:key components and other radio partners based on the EnOcean radio standard (ISO/IEC 14543-3-10). Integration of the radio parameters into the DDC4000 automation system and suitable building management systems.
  • Page 4: Connection

    Datasheet 2.50-40.132-01-EN Issue 2013-08-13 FBG132-FTL EnOcean System Gateway Product Description Connection 17 18 19 20 Wireless Interface Depending on the radio partner, radio communication with radio partners (e.g. TCF23, en:key RPW301-FTL room sensor, etc.) is cyclical, bidirectional and uses the EEP or MSC process.
  • Page 5 Issue 2013-08-13 Datasheet 2.50-40.132-01-EN Product Description FBG132-FTL EnOcean System Gateway EEP/MSC radio communication mode - FBG132-FTL with radio partners in EEP mode Feldbus FBG132-FTL MK10-FTL TCF23 MD15-FTL - FBG132-FTL with radio partners in MSC mode Feldbus FBG132-FTL RPW301-FTL MD10-FTL Page 5 / 10...
  • Page 6: Installation

    FBG132-FTL EnOcean System Gateway Product Description Installation NOTICE This product description describes specific settings and functions of the FBG132-FTL. In addition to these instructions, observe the product descriptions of other system components, such as DDC controller DDC4000. General radio installation instructions...
  • Page 7: Can Bus Installation Notes

    Issue 2013-08-13 Datasheet 2.50-40.132-01-EN Product Description FBG132-FTL EnOcean System Gateway CAN bus installation notes Lines for the mains supply and fieldbus are to be laid together in one shielded cable, cable type at least 0.8 mm in diameter, with the wires twisted together in pairs. Here, one stranded pair of wires is to be used for the mains supply and the other for the fieldbus.
  • Page 8: Settings And Led Displays

    Datasheet 2.50-40.132-01-EN Issue 2013-08-13 FBG132-FTL EnOcean System Gateway Product Description Settings and LED displays Setting the fieldbus address Permitted range for the fieldbus address: 01 to 63 The rotary switches for setting the fieldbus address are located inside the cover.
  • Page 9: Commissioning

    You can find more information in the PS4000 manual. NOTE A button cannot be used for teaching in on the FBG132-FTL. The radio ID of the radio partner is entered into the configuration parameters in the PS4000 planning system.
  • Page 10 Datasheet 2.50-40.132-01-EN Issue 2013-08-13 FBG132-FTL EnOcean System Gateway Product Description Page 10 / 10...

Table of Contents