Zip VARIPOINT II Series Installation Instructions & User Manual

Zip VARIPOINT II Series Installation Instructions & User Manual

Direct unvented water heaters

Advertisement

INSTALLATION INSTRUCTIONS & USER MANUAL
ZIP
VARIPOINT II
Direct unvented water heaters.
MODEL NUMBER:
VP103, VP153, VP103UB & VP153UB
INSTALLATION INSTRUCTIONS & USER MANUAL
210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB)
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VARIPOINT II Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Zip VARIPOINT II Series

  • Page 1 INSTALLATION INSTRUCTIONS & USER MANUAL VARIPOINT II Direct unvented water heaters. MODEL NUMBER: VP103, VP153, VP103UB & VP153UB INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 2: Table Of Contents

    Installation must only be undertaken by a competent person, familiar with unvented electric water heaters. The Zip Varipoint II must be installed in accordance with these instructions and all current legislation, codes of practice and regulations governing the installation of unvented hot water cylinders in force at the time of installation .
  • Page 3: General Product Description

    GENERAL PRODUCT DESCRIPTION These instructions will guide you through the installation, maintenance and use of the Zip Varipoint II, however, if you require any further information please call Zip customer service on 0345 6 005 005. • The Zip Varipoint II is an unvented water heater designed for connection directly to incoming mains water supply and can serve one or more outlets using conventional taps.
  • Page 4: Technical Data

    1/2” BSP (1) EU Regulation 812/2013;EN 50440 Dimensions Fixing Dimensions Model centres (mm) (mm) VP103 VP103UB VP153 VP15UB INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 5: Safety Information

    • Temperatures in excess of approximately 43°C are perceived as hot, especially by children, and may cause a feeling of burning. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 6: Cautions

    • When the appliance has been in use for some time, the fittings may be very hot. • The Zip Varipoint II is intended for connection to mains supply only. In any other case please contact Zip on 0345 6 005 005 for advice.
  • Page 7: Spare Parts

    Element 2.2 kW for underbasin models VP0303 Thermostat VP0304 Ressettable cut-out VP0317 Element Gasket VP0322 Wall fixing bracket INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 8: Pack Contents And Accessories

    Expansion vessel and check valve. Combined pressure reducer and line strainer. Thermostatic blending valve TMV2 & TMV3 rated Water block. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 9: Installation

    • These instructions must be read and fully understood before commencing the installa- tion. If in doubt, or in need of further guidance please ring Zip on 0345 6 005 005. • Installations must comply fully with UK Water Regulations, Building regulations part G3 and any Local Authority requirements.
  • Page 10: Positioning

    This is particularly relevant when the heater is located in a roof space, cupboard or any concealed location. For guidance please call Zip Customer Service on 0345 6 005 005. Wall Mounting Fig.
  • Page 11: Plumbing And Safety Control Arrangement

    • Drain valves should be fitted in both hot and cold water lines. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 12: Plumbing Installation Diagram

    VALVE TO BE DRAINED VIA TUNDISH (optional, not supplied). Zip recommend expansion vessels to be installed in line with the current HSE guidelines. Expansion vessels should be installed, in cool areas on cold flowing pipes, mounted as close to the incoming water supply to the water heater as possible, mounted...
  • Page 13: Electrical Installation

    230V AC supply only, this appliance must be earthed The Zip Varipoint II is pre-wired with a length of 3 core cable suitable for connection to a mains 230V AC supply. The cable is to be wired to a double pole fused spur, with a minimum break rating of 13 amps.
  • Page 14: Commissioning & Operation

    (The temperature cannot now be setto a value higher fixed on the selector). than that xed on the selector). INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 15: Maintenance

    MAINTENANCE Precautions • The Zip Varipoint II is an unvented electric water heater and only a competent person (electrician or plumber), familiar with unvented systems, should carry out any servicing and maintenance work on this unit. • DO NOT Remove the cover whilst the unit is connected to the electrical supply.
  • Page 16: Schedule

    Disconnect the inlet and outlet connections on the heater. • Remove the heater. • Drain the unit through the hot water supply connection INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 17: Fault Finding

    Faulty element. Check and replace as necessary. Thermostat failure. Check and replace as necessary. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...
  • Page 18: End Of Life Disposal

    In order to preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service for advice on 0345 6 005 005. INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK...
  • Page 19: Warranty

    Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance.
  • Page 20: Contact Details

    Zip Water UK 14 Bertie Ward Way, Dereham, Norfolk NR19 1TE 0345 6 005 005 sales@zipindustries.co.uk www.zipwater.co.uk INSTALLATION INSTRUCTIONS & USER MANUAL TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB) WWW.ZIPWATER.CO.UK...