Chapter 8 Parameters
P0-02
STS
Parameter
Attribute:
Operational
Interface:
Default: 01
Control
Mode:
Unit: -
Range: 00 ~ 127
8-16
249:The number of PR command exceeds the range
261:Index error occurs when accessing CANopen object
263:Sub-Index error occurs when accessing CANopen object
265:Data size error occurs when accessing CANopen object
267:Data range error occurs when accessing CANopen
269:CANopen object is read-only and write-protected
26b:CANopen object is not allowed in PDO
26d:CANopen object is write-protected when Servo ON
26F:Error occurs when reading CANopen object via EEPROM
271:Error occurs when writing CANopen object via EEPROM
273:The accessing address of EEPROM is out of range when
using CANopen object
275: CRC of EEPROM calculation error occurs when using
CANopen object
277:Enter the incorrect password when using CANopen object
283:Forward software limit
285:Reverse software limit
289:Feedback position counter overflows
301:CANopen fails to synchronize
302:The synchronized signal of CANopen is sent too fast
303:The synchronized signal of CANopen is sent too slow
304:CANopen IP command is failed
305:SYNC Period is in error
380:Position Deviation Alarm of DO.MC_OK. Please refer to
parameter P1-48.
Drive Status
Parameter for individual axis
Panel / Software
ALL
Communication
ASDA-M
Address: 0004H
0005H
Related Section:
Section 7.2
Revision December, 2014