455D Control Board; General Description; Technical Specifications; Features - FAAC 750 Manual

Hydraulic swing gate operator
Hide thumbs Also See for 750:
Table of Contents

Advertisement

1. General Description

The 455 D control board is used to operate the FAAC High
Voltage swing gate operators. It has several operating logics
built in, programmable with the help of a display and push-
buttons. The board allows connection of various accessories
including monitored photocell for compliance with the
UL325 standard Ed: 7.
The 455D control board allows the connection of 1 close
and up to 2 open entrapment protection devices.
The board should be installed in an enclosure that is con-
veniently located as close as possible to the gate operator.
All electrical connections from the control board to the
operator must be made in a weatherproof junction box.

2. Technical Specifications

Input Voltage
Input Power
Motor Max. Load
Accessories Max. Load
Electric Lock Max. Load
Ambient Operating Temperature Range
Protection Fuses

3. Features

Function Logics:
Semi-automatic / Automatic / Safety Devices / "Stepped" Semi-
automatic / "Stepped" Automatic / "Stepped" Safety Devices /
Semi-automatic B / Dead-man C
Opening/Closing Time:
Programmable (from 0 to 120 s)
Pause Time:
Programmable (from 0 to 4 min.)
Closing Leaf Delay:
Programmable (from 0 to 4 min.)
Opening Leaf Delay:
2 s (can be excluded)
Thrust Force:
Adjustable on 50 levels for each motor
Terminal Board Inputs:
Open / Open Free Leaf / Stop / Limit-switch / Opening Safety Devices
/ Closing Safety Devices / Power Supply + Earth.
Terminal Board Outputs:
Flashing Lamp / Motors / 24 VDC Accessories Power Supply / 24 VDC
Indicator-Light / Fail Safe / 12 VAC Electric Lock Power Supply
Programmable Functions:
Logic / Pause Time / Thrust Force / Torque at Initial Thrust / Opening and
Closing Leaf Delay / Reversing Stroke / Over-Pushing Stroke / Indicator-
Light / Pre-Flashing / Electric Lock / Fail Safe / Safety Devices Logic
/ Assistance Request / Detection Time of Obstacle or Contact Point
Learning Function:
Simple or complete work time learning, with or without Limit-switches

455D CONTROL BOARD

115 V~ ± 10% or
230 V~ +6% -10%
50/60 Hz
10 W
800 W
0,5 A
15 VA
-4°F to +131°F
5A (230V version)
10A (115V Version)
800 mA (accessory)
14

4. Layout and Components

F2
F1
F1
J4
J3
J3
J4
1
2
4
5
6
7 8
PE N L
OP
OP
CL
COM
COM
LAMP
M1
M2
MAIN
DL STATUS AND PROGRAMMING DISPLAY
J1 LOW VOLTAGE TERMINAL BLOCK
J2 CONNECTOR FOR RADIO RECEIVER
J3 AC POWER SUPPLY TERMINAL BLOCK
J4 MOTORS AND WARNING LAMP TERMINAL BLOCK
J5 INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BLOCK
J6 LIMIT-SWITCH TERMINAL BLOCK
F1 MOTORS AND TRANSFORMER PRIMARY WINDING
FUSE (F 5A - 230V) (F 10A - 115V)
F2 LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
"F" PROGRAMMING PUSH-BUTTON
F
"–" PROGRAMMING PUSH-BUTTON
"+" PROGRAMMING PUSH-BUTTON
+
Connector J2 - Rapid Connection to RP Receivers
The 5 pin J2 connector allows to plug in the FAAC RP radio
receivers
455 D
Terminal Block J3 - Power Supply
PE:
Earth Connection / Ground
N:
AC V~ power supply (Neutral)
L:
AC V~ power supply (Line)
The installer is responsible for grounding the operator
system, for providing the main power breaker switch,
and for making sure that the entire gate system meets
all applicable electrical codes.
DL
FSWOP
FCA1
F2
OP_A
FCC1
STOP
FCC2
OP_B
FSWCL
FCA2
+
F
+
F
J5
J6
J5
J1
J1
9 10 11 12 13 14 15 16 17 18 19
20 21
+
+
A
B
CL OP
-TX
LOCK
-
-
-
STP
+24V
OPEN
FSW
FSW
W.L.
RP 418 DS
RP 433 RC
J2
J2
J6
22
24 25
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

400

Table of Contents