Page 1
Installation instructions | for authorised electricians sonnenProtect 1300 for sonnenBatterie eco 8.2 or eco 9.43 KD-345 • Part no. 22041 • Version X02 info@sonnenbatterie.de • sonnenbatterie.de...
Page 2
IMPORTANT Read this documentation carefully before installation / operation. Retain this document for reference purposes. Publisher sonnen GmbH Am Riedbach 1 D-87499 Wildpoldsried Service number Email Document Document number Part number 22041 Version Valid for Publication date 19/02/2018...
Table of contents Table of contents 1 Information about this document .................... 5 Target group of this document .................... 5 1.2 Designations in this document .................... 5 1.3 Explanation of symbols...................... 5 2 Safety .............................. 7 2.1 Intended use .......................... 7 2.2 Requirements for the electrician .................. 7 2.3 Operating the sonnenProtect ....................
Page 4
Table of contents 7.2 Installing the mains filter .................... 23 7.3 Connecting the cable and strands ................. 24 7.3.1 Removing the dummy plug ................ 24 7.3.2 Installing the cable gland.................. 24 7.3.3 Wiring the cable.................... 25 7.3.4 Connecting the cables and strands.............. 25 8 Commissioning......................... 27 8.1 Commissioning the storage system ................
Information about this document | 1 1 Information about this document This document describes the installation of the sonnenProtect 1300 in connection with the sonnenBatterie eco 8.2 or eco 9.43 storage system. Read this document in its entirety. Keep this document in the vicinity of the sonnenBatterie. 1.1 Target group of this document This document is intended for authorised electricians.
Page 6
1 | Information about this document Symbol Meaning List ● Table 1: Additional symbols 6 / 36 Installation instructions sonnenProtect 1300...
• The electrician must be a person with a technical knowledge or sufficient experience to enable him/her to avoid dangers which electricity may create. • The company for which the electrician works must be certified by sonnen GmbH. • The electrician must have successfully complete sonnen GmbH certification train- ing for the product.
Therefore: Disconnect the sonnenProtect from the power (see Disconnecting the sonnen- Protect from the power supply [P. 32]). Only then can the sonnenProtect be opened.
Product description | 3 3 Product description 3.1 Technical data sonnenProtect 1300 System data Maximum power (2 sec.) 2,200 W Nominal power 1,300 W Output voltage (AC) 230 V +/- 10 % Nominal frequency 50 Hz Network configuration in emergency opera- tion Operating concept Single-phase power supply via plug outlet. The switch to emergency operation takes place automatically through the storage system.
3 | Product description 3.2 System components 3.2.1 System components of the sonnenProtect ON AL Test Reset Illustration 1: System components sonnenProtect 1 sonnenProtect 2 Plug outlet 3 F1.P (Z6) miniature circuit breaker 4 K2.P insulation monitor 3.2.2 Control and display elements ON AL Test K2.P...
Product description | 3 No. Designation Function ‘ON” LED Lights up when power supply is on (indicates emergency opera- tion). ‘AL’ LED Lights up when an insulation fault occurs, i. e. when the insula- tion resistance drops below the set alarm value (R <...
3 | Product description ON AL Test Reset kΩ Illustration 4: Emergency operation 1 Plug outlet of the sonnenProtect 2 sonnenProtect 3 F1.P miniature circuit breaker 4 Storage system 5 Insulation monitor 6 AC miniature circuit breaker 7 Residual current device (RCD) - 30 mA 8 Public grid (electrical mains) If a grid outage occurs, the connection to the public grid is disconnected in the storage system.
Product description | 3 • Technical data 3.5 Symbols on the outside of the sonnenProtect Symbol Meaning Warning: electrical voltage. Warning: electrical voltage. Wait five minutes after switching off 5 min (capacitor de-energising time). CE mark. The product meets the requirements of the applicable EU Directives.
4 | Transport and storage 4 Transport and storage Transport and storage conditions are defined in the product documentation of the storage system. Observe the same transport and storage conditions for the sonnenProtect. 14 / 36 Installation instructions sonnenProtect 1300...
Mounting | 5 5 Mounting 5.1 Scope of delivery Check the following scope of delivery to ensure it is complete. LINE LOAD ON AL Test Reset Illustration 5: Scope of delivery 1 sonnenProtect including connection cable 2 M20 cable gland 3 Mains filter 4 Pre-assembled strand - PE 5 Pre-assembled strand - N...
5 | Mounting 5.2.2 Observe minimum distances Observe the specified minimum dis- 30 cm tances between the device and the stor- 15 cm age system and neighbouring objects. Install the sonnenProtect at the same level as the top edge of the storage sys- tem, if possible.
Installation with sonnenBatterie eco 8.2 | 6 6 Installation with sonnenBatterie eco 8.2 DANGER Electrical work on the storage system Danger to life due to electrocution! Switch off the storage system to electrically isolate it. Disconnect the relevant electrical circuits. ...
6 | Installation with sonnenBatterie eco 8.2 6.2.1 Case 1: Sufficient free space on mounting rail Remove the end stop on the left side of the relay K1 on the mounting rail. Install the mains filter on the mount- ing rail.
Installation with sonnenBatterie eco 8.2 | 6 6.3 Connecting the cable and strands 6.3.1 Removing the dummy plug Tools: • Screwdriver with a thin blade (0.4 mm) Remove the dummy plug (1). A screwdriver with a thin blade can be used for this purpose.
6 | Installation with sonnenBatterie eco 8.2 6.3.3 Wiring the cable Wire the connection cable of the sonnenProtect through the cable gland to the inside of the storage sys- tem. Illustration 13: Connection cable of the sonnenProtect 6.3.4 Connecting the cables and strands Tools: •...
7 | Installation with sonnenBatterie eco 9.43 7 Installation with sonnenBatterie eco 9.43 DANGER Electrical work on the storage system Danger to life due to electrocution! Switch off the storage system to electrically isolate it. Disconnect the relevant electrical circuits. ...
Installation with sonnenBatterie eco 9.43 | 7 Option 2: use the GP measurement concept (setup 4) Advantage: the consumption of the electrical consumer connected to the sonnenPro- tect is added to the household consumption calculation through measurement point G (grid). Disadvantage: if the GP measurement concept has been used previously, the con- sumption measurement point needs to be changed.
7 | Installation with sonnenBatterie eco 9.43 7.3 Connecting the cable and strands 7.3.1 Removing the dummy plug Tools: • Screwdriver with a thin blade (0.4 mm) Remove the dummy plug (1). A screwdriver with a thin blade can be used for this purpose.
Installation with sonnenBatterie eco 9.43 | 7 7.3.3 Wiring the cable Wire the connection cable of the sonnenProtect through the cable gland to the inside of the storage sys- tem. Illustration 18: Connection cable of the sonnenProtect 7.3.4 Connecting the cables and strands Tools: •...
Page 26
7 | Installation with sonnenBatterie eco 9.43 LINE LOAD Illustration 19: Wiring inside the storage system 1 Inverter 2 Connection cable of the sonnenProtect 3 Mains filter 4 Earthing bolt 5 Cable lugs 6 Self-locking nut 7 Wire end ferrules 8 X3 connector ...
Commissioning | 8 8 Commissioning 8.1 Commissioning the storage system It is essential to follow the instructions in the given order when switching on a storage system with sonnenProtect because the storage system cannot otherwise function properly. 8.1.1 Switching on the miniature circuit breaker ...
In this case, check the wiring (see section Installation with sonnenBatterie eco 8.2 [P. 17] or Installation with sonnenBatterie eco 9.43 [P. 22]). Contact the sonnen customer service if the problem cannot be solved. 8.3 Setting up the sonnenProtect 8.3.1 Generating a commissioning code We recommend that you generate a commissioning code before installing the sonnenProtect on the premises of the storage system operator.
Commissioning | 8 1, 3 Ethernet line 2 Router of the home network 4 Laptop Enter the address ‘https://find-my.sonnen-batterie.com‘ into your browser’s ad- dress line. https://find-my.sonnen-batterie.com The following window appears: Illustration 22: Website find-my.sonnen-batterie.com Choose the storage system to be configured. To do this, click the Configure but- ton.
Page 30
8 | Commissioning Click on the button Settings . Select Backup Buffer . Change the percentage of the Backup Reserve to a desired value. Illustration 23: Settings page 30 / 36 Installation instructions sonnenProtect 1300...
Troubleshooting | 9 9 Troubleshooting Disturbance Possible reason(s) Correction Correct the insulation fault. The plug outlet of the sonnenProtect is There is an insulation fault. not supplying any power. The ‘AL’ LED of the insulation monitor is on. Wait until the public grid begins The plug outlet of the sonnenProtect is There is a grid outage.
10 | Decommissioning 10 Decommissioning DANGER Voltage in the event of a grid outage Danger to life due to electrocution! The plug outlet of the sonnenProtect remains live even in the event of a grid out- age or when the main fuses are switched off. ...
Uninstallation and disposal | 11 11 Uninstallation and disposal 11.1 Uninstallation DANGER Improper uninstallation of the sonnenProtect Danger to life due to electrocution! The sonnenProtect must only be uninstalled by authorised electricians. 11.2 Disposal The sonnenProtect must not be disposed of as domestic waste! ...
Page 34
GmbH Am Riedbach 1 D-87499 Wildpoldsried...
Need help?
Do you have a question about the Protect 1300 and is the answer not in the manual?
Questions and answers