Telenetics 202T, MIU202T Installation & Operation Manual

Telenetics 202T, MIU202T Installation & Operation Manual

Industrial grade, bell 202t standalone modem
Hide thumbs Also See for 202T, MIU202T:

Advertisement

Installation, Operation & Diagnostics
for the
MIU202T
Industrial Grade, Bell 202T
Standalone Modem
Document No. 49-0002-011 Rev. A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 202T, MIU202T and is the answer not in the manual?

Questions and answers

Summary of Contents for Telenetics 202T, MIU202T

  • Page 1 Installation, Operation & Diagnostics for the MIU202T Industrial Grade, Bell 202T Standalone Modem Document No. 49-0002-011 Rev. A...
  • Page 2 Telenetics Corporation ARC Electronics 800-926-0226 Document No. 49-0002-011 Rev. A...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. STANDARDS ...2 2. PRODUCT OVERVIEW ...3 3. GENERAL PRODUCT SPECIFICATIONS ...4 MODEM SPECIFICATIONS ... 5 5. ANALOG LINE SPECIFICATIONS ...7 6. ANALOG MICROWAVE INTERFACE...8 7. POWER CONNECTIONS ...10 8. SERIAL DATA PORT PIN-OUT...11 9. DIP SWITCH FUNCTIONS ...12 10.
  • Page 4: Standards

    1. STANDARDS Meets FCC Rules Part J, Subpart 15, Class A for radiated emissions. MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 2...
  • Page 5: Product Overview

    Internally, the MIU202T consists of a baseboard and a communication module. The baseboard includes the power supply regulation and surge protection. The communication module is a Telenetics™ Pony Express™ PE202T Modem Module. The MIU202T is packaged specifically for the harsh environments found in utility substations and industrial facilities.
  • Page 6: General Product Specifications

    3. GENERAL PRODUCT SPECIFICATIONS Dimensions: Weight: Voltage Supply: Standard Model: LV Model (Suffix “-LV”): Current Requirements: 12VDC 24VDC 65mA 27mA Surge Protection: Operating Temperature: Operating Humidity: Storage Temperature: MIU202T Installation, Operation & Diagnostics 125VDC 120VAC 7.5mA 6.5mA Power Supply: 8kVrms Analog Line: 3.75kVac Digital Line:...
  • Page 7: Modem Specifications

    MODEM SPECIFICATIONS Modulation: Modulation Type: Synch/Async: Data Rate: Transmit Frequency: Error Correction: Data Compression: Data Modulation Connectivity: 99.999% or better at -37dBm 99.5% or better at -40dBm 95% or better at -43dBm Serial Formats and Flow Control: Asynchronous and RTS/CTS flow control Analog Interface Tx Output Level: Rx Sensitivity:...
  • Page 8 Other Features Receiver Equalization: Self Test Diagnostics: Local Analog Loopback: Local Digital Loopback: Remote Analog Loopback Remote Digital Loopback Anti-Streaming: RTS/CTS delay: Constant Carrier Soft Carrier Turn Off Carrier Turn ON/OFF * Dip Switch Selectable ~ See Section 9 MIU202T Installation, Operation & Diagnostics Compromise Equalization None See Section 13...
  • Page 9: Analog Line Specifications

    5. ANALOG LINE SPECIFICATIONS The MIU202T contains analog circuitry for connection to the public conditioned or unconditioned, Bell type 3002, 2 or 4-wire, full duplex voice grade leased lines or metallic lines (eg; pilot wires). The MIU202T will also interface to Power Line Carrier or Microwave radio voice channel networks.
  • Page 10: Analog Microwave Interface

    6. ANALOG MICROWAVE INTERFACE The MIU202Tis designed to interface to a Microwave radio voice channel network with the following specifications: Phase Jitter (10 to 300Hz)1 degree peak-to-peak, max. Frequency Response: Frequency Stability: Level Stability (w/o regulation): + 0.5 dB (6 months) Harmonic Distortion: Absolute Delay: Group Delay (option - 001):...
  • Page 11 Crosstalk (unintelligible): Adjacent channel Intra-channel Out of Band Signalling: Frequency 3825 Hz MIU202T Installation, Operation & Diagnostics 28dBrnc0 maximum (24 455B weighted noise at 0 dBmO dBrnc0 typical). 28 dBrnc0, maximum (18 dBrnc0, typical) (1KHz test tone at 0 dBmO) Level -20 dBmO Pulse speed (30 to 80% break) 8 to 14 pps Pulse distortion +3 dB, level var.
  • Page 12: Power Connections

    POWER CONNECTIONS MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 10...
  • Page 13: Serial Data Port Pin-Out

    SERIAL DATA PORT PIN-OUTS MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 11...
  • Page 14: Dip Switch Functions

    9. DIP SWITCH FUNCTIONS IMPORTANT NOTE: Invert modem to view dip switches as shown above Table 1 Switch Function Switch 1 Transmit Analog (TxA) Signal Level Switch 2 Anti-Streaming Switch 3 Received Analog (RxA) Signal Level Switch 4 RTS/CTS Delay Switch 5 RTS/CTS Delay Switch 6...
  • Page 15 Table 2: RTS/CTS Delay Time Switche Wire Wire Carrie MIU202T Installation, Operation & Diagnostics Constan Switch Switch Carrie Edition: April 4, 1998 Switch 9 RTS/CTS Soft Delay Carrier Time 50 ms 50 ms 50 ms 50 ms 35 ms 55 ms 35 ms 35 ms 12 ms...
  • Page 16: Modem Configuration

    10. MODEM CONFIGURATION The following table provides the Dip Switch settings required for most modem application configurations: 4-Wire Point-to-Point 4-Wire Multi-Point Master 4-Wire Multi-Point Slave Rx Term. OFF 4-Wire Multi-Point Slave Rx Term. ON 2-Wire Point-to-Point 2-Wire Multi-Point Master Line Term. ON 2-Wire Multi-Point Slave...
  • Page 17: Led Indicator

    LED INDICATOR MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 15...
  • Page 18: Outline Drawing & Mounting

    12. OUTLINE DRAWING & MOUNTING MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 16...
  • Page 19: Diagnostics

    DIAGNOSTICS The following pages provide hardware techniques for diagnosing communication problems and thereby isolating the problem at the local modem, the remote modem or the interconnecting line. (a) LOCAL ANALOG LOOPBACK (Figure 2) Requires a loop back cable with a built-in circuit for line loss to simulate a typical leased line condition (See Figure 3).
  • Page 20 Test 3: Received Signal Level Set Dip Switch 1 OFF (TxA = -10dBm) and Dip Switch 3 OFF (RxA = -43dBm). CD will be ON. Run a test message at TxD and verify that the same message is received at RxD with no data errors. Test 4: Repeat Test 3 for various RTS/CTS delay times and with soft carrier ON and OFF.
  • Page 21 (c) REMOTE DIGITAL LOOPBACK – 4/Wire Network (Figure 5) Configure both the local and remote modems as follows: Switch 1 = ON (TxA = 0dBm) Switch 3 = ON (RxA = -33dBm) Switch 4 = OFF (RTS/CTS = 35ms) Switch 5 = ON (RTS/CTS = 35ms) Switch 6 = ON (Constant Carrier mode).
  • Page 22 (d) LINE DIAGNOSTICS (i) Typical modem configuration for 4-wire Point-to-Point system… Switch 1 = ON (TxA = 0dBm) Switch 3 = ON (RxA = -33dBm) Switch 4 = OFF (RTS/CTS = 1ms) Switch 5 = OFF (RTS/CTS = 1ms) Switch 6 = ON (Constant Carrier mode). Switch 7 = OFF (4-Wire) Switch 8 = ON (Line Termination = 600 ohms) Switch 9 = OFF (Soft Carrier = OFF)
  • Page 23 MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 21...
  • Page 24 MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 22...
  • Page 25 MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 23...
  • Page 26 NOTES: MIU202T Installation, Operation & Diagnostics Edition: April 4, 1998 Page 24...

This manual is also suitable for:

Miu202t

Table of Contents