Page 1
Midwest Air Technologies, Inc., 625 Barclay Boulevard, Lincolnshire, IL 60069 1/12/03 Task Force® is a registered trademark of LF, LLC. All Rights Reserved FORCE circuit and Parts List all safety precautions and operating Item #83691 For customer service, contactq 1-800-628-8815 ext. 5000 instructions before using Part No.
The information listed below should understood by the operator. given to protect the user while Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury CFM: Cubic feet per minute.
Important Safety Instructions and Guidelines Improper operation or maintenance of this product could result in serious injury and/or property damage. Read and understand all The air compressor should be operated on a dedicated 15 amp circuit. If the circuit does not have 15 free amps available, a larger circuit must be used.
Risk of Do not use the air compressor in the rain or wet conditions. Electrical repairs should be performed by authorized personnel such as an electrician and should comply with all Electrical Shock national and local electrical codes. The air compressor should also have the proper three prong grounding plug, correct supply voltage, and adequate fuse protection.
Daily Start-Up Procedures 1. Set the On/Off switch to the Off position. 2. Check the air compressor visually for any damage or obstruction. 3. Close the drain valve. 4. Plug the power cord into the proper receptacle. 5. Turn the On/Off switch to the On position and the compressor should start and build air pressure in the tank to cut-out pressure and then shut off automatically.
The air compressor should be turned off and unplugged source before any maintenance is performed as well as the PROBLEM Air leak from safety valve. Pressure reading on the regulated pressure gauge drops when an accessory is used. Excessive tank pressure. Air leaks from the tank body tank welds.
AiR COMPRESSOR MODEL LFD2H PART UST Ref. # Part Number Description DC Motor Motor Bolt, M5 x 0.8 x 110 Lock Washer, 5ram Motor Housing Eccentric Connecting Rod Bearing Piston Ring Piston Plate Valve Screw, M3 x 0.5 x 5 Crankcase Cover Ground Screw, M5 x 0.8 x 8...
Midwest Air Technologies, Inc. warrants to the original purchaser that each new air compressor and service part is free from defects in material and workmanship and agrees to repair or replace under this warranty any defective product or part as follows from the original date of purchase. 1 YEAR - Warranty on all air compressor products.