DESCRIPTION
The Art.4850R is an expansion proximity reader that can be connected to the
Art.4810 GSM PRO intercom via the RS485 bus connection. It allows the GSM
intercom to have up to 7 additional proximity access doors or can be used with
a combination of proximity and coded access using the Art.4903 keypad (up to
a total of 8 devices with the GSM PRO's onboard reader as device ID.1).
The front of the module has a tri-colour LED to indicate to the user the status of
the reader (amber = standby, green = access granted and red = access denied).
The reader is housed in a 4000 series module with a stainless steel or aluminium
surround front frame, see Fig.1.
When connected to the GSM PRO module with the RS485 bus connection it
can be programmed by either sending SMS text messages (refer to technical
manual: GSM4KCR_66250754_EN_V1-0 or later) or by using the GSMSK PC
software (refer to technical manual: GSMSK_66251720_EN_V2-0 or later).
It has a single onboard relay with common (C), normally open (NO) and normally closed (NC) connections and a switched 0V push
to exit input (PTE) to enable the activation of the relay. The relay operating time can be set for 01 - 99 seconds or 00 for latching
and can be programmed by using a combination of the tens, units and store buttons on the back of the module (also refer to
programming the relay time on page 2). Presenting a programmed fob will activate the relay for the programmed relay time. The
relay can also be activated via a push to exit button (configured as a push-to-make switch) when connected across - and PTE. It
should also be noted that when the relay time has been set for latching (00) the push to exit button will operate as a "toggle" switch
to latch the relay open and latch the relay closed.
The unit ID (1 - 8) can be set by using a combination of the units, store and delete buttons on the back of the module (also refer to
setting the unit ID on page 3).
IMPORTANT NOTE: The Art.4850R reader can only be used as an expansion reader for the Art.4810 GSM PRO intercom.
Programming can only be carried out (when connected by RS485) by sending SMS text messages to the GSM PRO intercom
or using the GSMSK PC software (software version 4.0.0.0 or later). The only manual programming that can be performed on
the module is the unit ID setup and relay time. All proximity fob data is stored in the GSM PRO module's memory and not the
proximity reader.
Compatible key fobs: 955/T and/or PBX-1E; compatible proximity cards: 955/C and/or PBX-2.
IMPORTANT NOTE: MIFARE PROXIMITY FOBS/CARDS CANNOT BE USED WITH THIS READER.
Art. 4850R - Installation Instructions
Expansion Proximity Reader Module for the GSMPRO
103mm
4850R
LEGEND
Proximity reading area
Status indication LED
Current firmware version (FW X.X)
Programming indication LED's (yellow)
Tens and Units programming buttons
Power input terminals
PTE input & relay (C/NC/NO) terminals
RS485 bus termination jumper
RS485 bus terminals
Store and Delete programming buttons
Store LED (green) and Delete LED (red)
- 1 -
ENG
STEEL
ALI
HIGH BRASS
MATTE
66250407 - V1.1 - 20/02/19

Advertisement

loading
Need help?

Need help?

Do you have a question about the 4000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Videx 4000 Series

  • Page 1 (amber = standby, green = access granted and red = access denied). PTE input & relay (C/NC/NO) terminals The reader is housed in a 4000 series module with a stainless steel or aluminium surround front frame, see Fig.1.
  • Page 2: Lock Release

    4000 Series Art. 4850R Expansion Proximity Reader Module for the GSMPRO OPERATION In standby the status indication LED on the front of the Art.4850R reader (Fig.1, ) will be switched ON (amber). Access Granted: To operate the relay on the reader present a programmed fob/card to the proximity reading area (Fig.1 ).
  • Page 3 Working Temperature: -10 +50 IT IS RECOMMENDED THAT ANY CABLING AND VIDEX PRODUCTS BE INSTALLED BY A COMPETENT AND QUALIFIED ELECTRICIAN, SECURITY INSTALLATION SPECIALIST OR COMMUNICATIONS ENGINEER. For further cabling information and installation notes refer to the wiring diagram on page 4.
  • Page 4 UNIT ID’s 3, 4, 5 and 6 performance of the system therefore Videx DO NOT recommend these types of cable. LAST RS485 DEVICE IN LINE Art.4850R...
  • Page 5 4000 Series GSM Audio Intercom with Proximity Notes - 5 - 4000 Series GSM Audio Intercom - Technical Manual 66250407 - V1.1 - 20/02/19...
  • Page 6 4000 Series GSM Audio Intercom with Proximity Notes - 6 - 4000 Series GSM Audio Intercom - Technical Manual 66250407 - V1.1 - 20/02/19...
  • Page 7 DISPOSAL In accordance with the Legislative Decree no. 49 of 14 March 2014 “Implementation of the Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)”. The crossed-out bin symbol on the equipment or on the packaging indicates that when the product reaches the end of its lifetime, it must be collected separately from mixed municipal waste.
  • Page 8 MANUFACTURER VIDEX ELECTRONICS S.P.A. FABBRICANTE Via del Lavoro, 1 FABRICANT 63846 Monte Giberto (FM) Italy FABRICANTE Tel (+39) 0734 631669 FABRIKANT Fax (+39) 0734 632475 ‫الشركة المص ن ّ ِ عة‬ www.videx.it - info@videx.it CUSTOMER SUPPORT VIDEX ELECTRONICS S.P.A. UK Customers only: SUPPORTO CLIENTI www.videx.it - technical@videx.it...

This manual is also suitable for:

4850r