Taking care of the pot
For the pot, carefully follow the instructions below:
• To ensure the maintenance of pot quality, it is recommended not to cut
food in it.
• Make sure you put the pot back into the rice cooker.
• Use the plastic spoon provided or a wooden spoon and not a metal type
so as to avoid damaging the pot surface – fig.14.
• To avoid any risk of corrosion, do not pour vinegar into the pot.
• The color of the pot surface may change after using for the first time or
after longer use. This change in color is due to the action of steam and
water and does not have any effect on the use of the rice cooker, nor
is it dangerous for your health. It is perfectly safe to continue using it.
Cleaning the micro pressure valve
• When clean the micro-pressure valve, please remove it from the lid –
fig.15
and open it by rotating in the direction of "open" –
16b. After cleaning it, please wipe dry it and meet the two triangle in
the two parts together and rotate it in the direction of "close", then put
it back to the lid of the rice cooker –
Cleaning and care of the other parts of the appliance
• Clean the outside of the Rice Cooker – fig.18, the inside of the lid and
the cord with a damp cloth and wipe dry. Do not use abrasive products.
• Do not use water to clean the interior of the appliance body as it could
damage the heat sensor.
TECHNICAL TROUBLESHOOTING GUIDE
Malfunction
description
Any indicator lamp
off and no heating. Rice cooker not plugged.
Any indicator lamp
off and heating.
Steam leakage
during using.
15
Causes
Problem of the connection
of the indicator lamp or
indicator lamp is damaged.
Lid is badly closed.
Micro pressure valve
not well positioned or
uncomplete.
Lid or micro pressure valve
gasket is damaged.
fig.17a and
17b.
Verify the main plug is well
engaged in the product body.
Send to authorized service
center for repair.
Open and close again the lid.
Stop the cooking (unplug the
product) and check the valve
is complete (2 parts locked
together) and well positioned.
Send to authorized service
center for repair.
fig.16a and
Solutions