6.9.2

Direct connection to GX Soft

Server address – address of the computer running the GX Soft program. It must be a public
address. You can enter the IP address or domain name.
Port – number of the TCP port used for direct communication between the module and
the computer with GX Soft program. You can enter values from 0 to 65535 (0=disabled).
Server address from SMS – if this option is enabled, the address of server, to which
the module is to connect, and the port number can be entered in the content of SMS
message initiating the connection. If the address is not entered, the module will connect to
the computer whose address has been programmed in the module.
SMS function – the function that is run on receiving the control message. The function
enables direct connection between the module and the GX Soft program to be established
via cellular network.
SMS command – the control command which, if sent in the SMS message, will initiate
communication between the module and the GX Soft program. You can enter up to 16
alphanumeric characters except spaces (digits, letters and special characters).
The command content must be different from that of the other control commands
programmed in the module.
In the SMS message, you can include address of the computer the module is to
connect to, and the number of TCP port which is to be used for communication.

6.10 Station simulation

Station simulation – if this option is enabled, the module can receive event codes from
a device connected to the telephone line output (the module simulates the monitoring
station).
Events buffering – if this option is enabled, each event received by the module from the
control panel is written to the module event log and confirmed immediately on receipt.
If the option is disabled, events from the control panel will not be written to the module
event log, and the received event will only be confirmed after the module receives
acknowledgement of the event receipt by the monitoring station.
No voltage on TIP/RING if GSM trouble – if this option is enabled, voltage on the telephone
line terminals will be turned off in case of the cellular telephone trouble.
GPRS-A LTE