12. TROUBLE SHOOTING

In case of an unexpected event, caused by software or hardware reasons, the operator is prompted
with the message E r r x x , where xx is the Error code. Program is halted.
)
Press
momentarily to acknowledge the error and proceed as indicated in the error operator
response. Errors may occur during setup, programming, power-up and during operation.
In all other cases of malfunction the user should contact the supplier, as the unit may probably
need service from an experienced technician
DISPLAY
Err 01
SYSTEM ROM : Faulty EPROM.
Err 02
DATA RAM : Faulty CMOS RAM.
Err 04
CALIBRATION DATA : Faulty
EEPROM.
Err 05
SCALE or A/D CONVERTER.
Err 06
LOW INPUT VOLTAGE .
Err 15
System has been initialised due to
power failure or soft reset.
Err 20
PRINTER IS NOT ON-LINE. Either not
connected or out of paper or failed.
Err 26
No paper for EPSON TM295 printer.
Err 50
Small sample count.
Err 51
Small sample weight.
Err 67
Corrupted totaliser.
Err 69
TOTALISER OVERFLOW.
Because totalisers have not been
cleared for long time.
. . . .
To exit from error display press
LD5208 U
M
, R
26
SER
ANUAL
LIST OF ERROR CODES
POSSIBLE CAUSE
)
. 0: N
2005
EV
OVEMBER
ACTION TO BE TAKEN
Contact manufacturer.
Contact manufacturer.
Contact manufacturer.
Check scale, cable, connectors,
contact manufacturer.
Check power supplied to the
instrument.
Zero scale.
Check printer cables. Press
)
Or
to abort.
Supply with paper.
Retry.
Retry.
Clear totalising memory.
Print / clear totalisers. Overflow is not
critical. But remember that 1 total
capacity must be added to the
indication, each time an overflow
occurs.
.
(