Hide thumbs Also See for SB2 Series:

Advertisement

2
Art. No.: 0967 SB
-22
2
Art. No.: 0968 SB
-12
Art. No.: 0969 SB
2
-12A
FB 04-243 Rev. 6
Revision: 27.06.2016
Manual
2
SB
-Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SB2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for hadewe SB2 Series

  • Page 1 Manual -Series Art. No.: 0967 SB Art. No.: 0968 SB Art. No.: 0969 SB -12A FB 04-243 Rev. 6 Revision: 27.06.2016...
  • Page 2: Table Of Contents

    Directory Foreword Safety instructions Cleaning & Disinfection Getting to know the unit Before the use Range of application Installation site Application Operation Working positioning Suction Changing filter bag Changing control unit filter Clamping the bur/ tool Setting up the speed Foot switch LCD Display Messages...
  • Page 3: Foreword

    Foreword The SB foot care unit was produced according to strict quality criteria and uses the latest technology in its design. The images in this manual may vary slightly from the product you have bought as we are constantly developing our products. This user manual includes a detailed description and explanation of how to use the SB unit.
  • Page 4: Safety Instructions

    Safety Instructions The equipment should only be Prevent your hair from used by trained operators. wrapping itself around moving parts. If applicable, wear a hair net. The installation of the working area has to correspond to the When working with materials, relevant regulations.
  • Page 5 Safety Instructions • liquids). the inserted tool sits properly in the chuck and will not cant/jam while Always follow the operating clamping it instructions. • the tool is approved for using it at Do not carry out any repairs, the max speed (see manufacturer´s modifications maintenance work...
  • Page 6: Cleaning & Disinfection

    Safety Instructions Cleaning and disinfection The device is designed to be compatible with rotating instru- ments which do not penetrate the skin or mucosal or inadvertently may still cause injuries. For this application please adhere to the cleaning and disin- fection instructions provided below.
  • Page 7: Getting To Know The Unit

    Getting to know the unit Gerät kennen lernen 1 Decrease the suction output 2 Increase the suction output 3 Reduce the speed 4 Increase the speed 5 Display of speed/ suction level 6 Change direction of rotation 7 LED: ON during reverse rotation 8 Main switch 9 Switching ON/OFF the unit (Standby) 10 Connecting socket for foot switch...
  • Page 8: Before The Use

    Before the use Please read through the instructions Installation site carefully before using the unit and The working area must conform to carefully note the safety advice. the conditions described. Set up the Always keep this manual accessible unit in such a way, that the air slits to any users of the drill.
  • Page 9 Before the use . Check that the filter bag and dust filter are correctly fitted. Ensure that the tool is fixed. On the left side in the back of the device you will find the main power switch. Press this switch to turn the unit on.
  • Page 10: Application

    Application Operation If you want to take a break or finish the job press the standby button In the following section the order in (14). The handpiece motor and which you should use the device is suction will turn off. The handpiece described.
  • Page 11 Application Work positioning The following images are examples of how to work on various parts of the foot. Always make sure that the foot is firmly gripped and that you can work freely and without strain.
  • Page 12 Application...
  • Page 13: Suction

    Application Suction Switch on the suction with button (8). The suction output can be regu- lated in 5 levels. You will see the selected level in the display. Level 0 would mean that the suction is turned off. Pull out the lid of the dust chamber and remove the old filter.
  • Page 14: Clamping The Bur/ Tool

    Operation of the footswitch: and leave it there. Now insert the Only use the original hadewe foot tool as far as possible. Pull back the switch, to avoid any damages. knob and the tool will be firmly...
  • Page 15: Maintenance & Care

    Maintenance & Care Cleaning the chuck Because of the additional protection washer (see right), not much dirt is usually entering the handpiece. In the process of time, some dirt might collect itself within the handpiece, and might affect its functions. Therefore the chuck has to be To assemble the chuck follow the cleaned monthly.
  • Page 16 Maintenance & Care Maintenance overview What has to be done? How often? Done by whom? Cleaning the chuck, Monthly by user changing the washer 4571 Changing filter Each 50 hours of 5115 or 5179 operation by user (check after each 10 hours) Changing filter 3752 Each 200 hours of...
  • Page 17: Handling Instructions

    Its moisture could damage the interior parts of the handpiece. Any materials used by hadewe prevend formation of rust. In cases in which a rust infestation was found within handpiece, thorough inspections...
  • Page 18 Handling instructions Do not work with tools you use is according to the work which you are doing and the instru- - are bent or out of balance ments you are working with. - whose shaft is worn out or - are rusty.
  • Page 19: Troubleshooting

    Footswitch is used constantly or bur/tool itself can be tested with the faulty  Pull out the socket of the hadewe Bur Shaft Tester (Art. No. foot switch to see if this is the cause (4990) to see if it is bent).
  • Page 20 Technical Details 0967 SB 0969 SB Total weight: 3,8 kg Total weight: 3,8 kg Dimension: W273xH142xD186mm Dimension: W273xH142xD186mm Input:230V, AC voltage 50Hz, 0,9A Input:230V, AC voltage 50Hz, 0,9A vacuum: 2,9 – 5,8 kPa vacuum: 2,9 – 5,8 kPa Fuse primary: Fuse primary: F1: 315 mA time delayed safety fuse F1: 315 mA time delayed safety fuse...
  • Page 21 2 in accordance with DIN 374-2 93/42/EEC medical devices directive during the disassembling of the device. Also, wear a protective hadewe GmbH – Grambartstraße 10 – 30165 Hannover mask for your face according EN 14683 version IIR or EN 149 FFP2.
  • Page 22 Technical Details Symbol Safety Check A safety check must be done in compliance with the regulations of Caution! the country where the device is used. The inspection interval is Important Note! once a year. Follow instructions for use Repeated control and control after Temperature limit (indi- repair (DIN EN 62535, VDE 0751-1) cates the lower and upper...
  • Page 23 Electromagnetic Compatibility Guidance and Manufacturer's Declaration – Electromagnetic Emissions The device is suitable for use in the specified electromagnetic environment. The customer and/or the user of the pa-on should assure that it is used in an electromagnetic environment as described below: Emissions Test Compliance...
  • Page 24 Electromagnetic Compatibility Guidance and Manufacturer's Declaration – Electromagnetic Immunity IEC 60601-1-2 The device is suitable for use in the specified electromagnetic environment. The customer and/or the user of the device should assure that it is used in an electromagnetic environment as described below: Immunity Test IEC 60601 Test...
  • Page 25 Electromagnetic Compatibility Guidance and Manufacturer's Declaration – Electromagnetic Immunity IEC 60601-1-2 The device is suitable for use in the specified electromagnetic environment. The customer and/or the user of the device should assure that it is used in an electromagnetic environment as described below: Immunity Test IEC 60601 Test Level...
  • Page 26 Electromagnetic Compatibility a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be consid- ered.
  • Page 28 GmbH Grambartstraße 10 30165 Hannover Germany info@hadewe.de www.hadewe.de...

This manual is also suitable for:

Sb2 22Sb2 12Sb2 12a

Table of Contents