Firman P03501 Owner's Manual
Hide thumbs Also See for P03501:

Advertisement

OWNER'S MANUAL
PORTABLE GENERATOR
IMPORTANT:
Record product information to reference when ordering parts or
obtaining warranty coverage.
DO NOT RETURN TO
STORE!
Read all safety precautions and instructions carefully
before operating equipment.
Ensure engine is stopped and level before performing
any maintenance or service.
MODEL NUMBER
P03501
Rev Level:01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P03501 and is the answer not in the manual?

Questions and answers

Summary of Contents for Firman P03501

  • Page 1 OWNER’S MANUAL PORTABLE GENERATOR MODEL NUMBER P03501 Rev Level:01 IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Ensure engine is stopped and level before performing any maintenance or service. Record product information to reference when ordering parts or obtaining warranty coverage.
  • Page 2: Table Of Contents

    Table of Contents Trouble Shooting..... .24 Parts Diagram and Parts List ...25 Generator Parts Diagram .
  • Page 3: Important Safety Information

    INTRODUCTION Thank you for purchasing a FIRMAN generator. Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings in this manual and the tags and decals affixed to the unit are therefore not all-inclusive.
  • Page 4 SAFETY PRECAUTIONS WARNING WARNING • WARNING POISONOUS GAS HAZARD. • • • •...
  • Page 5 CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: Near any door, window or vent Garage Basement...
  • Page 6 WHEN OPERATING EQUIPMENT WARNING • • DO NOT tip engine or equipment at angle which causes fuel to spill. • DO NOT stop engine by moving choke • control to “Start” position. WHEN TRANSPORTING, MOVING • OR REPAIRING EQUIPMENT • NEVER start or stop engine with electrical Transport/move/repair with fuel tank devices plugged in and turned on.
  • Page 7 • When using generator for backup power, WARNING notify utility company. Unintentional sparking • Use a ground fault circuit interrupter (GFCI) could cause fire or in any damp or highly conductive area, electric shock resulting such as metal decking or steel work. in death or serious •...
  • Page 8: Unpacking The Generator

    1. Axle Pin ....... . .2 NOTE: 2. 8.0" in. Wheel ......2 Improper treatment of generator could damage 3.
  • Page 9 REMOVAL OF SHIPPING SUPPORTS Before you can run your new generator, follow these simple instructions: CAUTION 3. You may discard these brackets, as they are no longer Failure to remove these items can result required for normal operation of your generator. in damage to your generator, possible Your generator is now ready for use.
  • Page 10 ASSEMBLY Install the Handle The generator requires some assembly prior to 1. Place the handle K over the mounting channel usage. on the frame. Install the Wheel Kit 2. Secure the handle to the frame using the two handle flange bolts H(M8x45). 3.
  • Page 11 5- Fuel Valve 13- Control Panel 6- Air Filter 14- Handle 7- 208cc FIRMAN OHV Engine 8- Recoil Starter *We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on this page.
  • Page 12: Control Panel

    Control Panel NOTE: Total power drawn from all receptacles must not exceed the name plate rating. Engine Switch - Flip the switch to the 120V, 20A Duplex – (NEMA 5-20R) 20 Amp “ON”(l) position and pull the recoil starter of current may be drawn from this 120 Volt to start the generator.
  • Page 13: Specifications

    SPECIFICATIONS Model P03501 Starting Watts 4450 3550 Running Watts Rated AC Voltage 120V Rated Fequency 60Hz Phase Single Voltage Regulator Power Factor Alternator Type Brushed Engine FIRMAN Engine Type Single Cylinder, 4-Stroke OHV Air Cooled Displacement 208cc Low Oil Shutdown...
  • Page 14 4.Using oil funnel, slowly pour contents of Add Engine Oil provided oil bottle into oil fill opening to the "H" mark on dipstick. Be careful do not CAUTION overfill. Overfilling with oil could cause the engine to not start or hard starting. NOTE: Degrees Celsiusº(Outside) 5.Replace oil fill cap/dipstick and fully tighten.
  • Page 15 Add Fuel Fuel must meet these requirements: • Clean, fresh, unleaded gasoline. • Use regular UNLEADED gasoline with the generator engine with a minimum 87 octane / 87 AKI (91 RON). For high altitude use, see "Operation at High Altitude". •...
  • Page 16 THE GENERATOR (STATOR WINDING) AND THE Installation instructions are also available in the FRAME. Technical Bulletin area of the FIRMAN internet site. The part number and recommended minimum Connecting to a Building's Electrical System altitude for the application of the high altitude carburetor main jet is listed in the table below.
  • Page 17 OPERATION • Generator Location WARNING Make sure you review each warning in order to • prevent fire hazard. Keep area clear of inflammables or other hazardous materials. Select a site that is dry, well ventilated and protected from the weather. •...
  • Page 18: Starting The Generator

    7. Pull the starter cord slowly until resistance is Starting the Generator felt and then pull rapidly. 1. Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment. 2. Check oil level and fuel. 8.
  • Page 19: Connecting Electrical Loads

    Connecting Electrical Loads This unit has been pretested and adjusted to handle its full capacity. Before starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for Stopping the Engine correct output.
  • Page 20 7. Repeat steps 5-6 for each additional item. 1.DO NOT try to restart the engine. 2.Contact an Authorized FIRMAN Service Dealer. 3.DO NOT operate engine until oil level is corrected. If oil level is below LOW mark on dipstick: 1.Add oil to bring level to HIGH mark.
  • Page 21: General Recommendations

    MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE Every Daily(Before Initial Every 100 hours ITEM NOTES operation) 25 hours 50 hours (or annual) Check condition. Adjust gap √ Spark Plug and clean. Replace if necessary. √ Check oil level. Engine Oil √ √ Replace.
  • Page 22: Engine Maintenance

    • Use fresh and high quality lubricating oil to the ENGINE MAINTENANCE specified quantity. If contaminated or deteriorated oil is used or To prevent accidental starting, remove and the quantity of the engine oil is not sufficient, ground spark plug wire before performing any engine damage will result and its life will be service.
  • Page 23: Inspect Muffler And Spark Arrester

    Spark Plug Maintenance Cleaning Fuel Strainer Changing the spark plug will help your engine Dirt and water in the fuel are removed by the fuel to start easier and run better. strainer. (a) Remove the spark plug cap. (b) Remove spark plug using provided wrench. (a) Remove the strainer cup and throw away water and dirt.
  • Page 24 • DO NOT touch hot parts and AVOID hot exhaust CAUTION gases. • Failure to clean the spark arrester will result in Allow equipment to cool before touching. degraded engine performance. • Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
  • Page 25 Long Term Storage 8-Keep the engine switch and fuel valve on “OFF” position. It is important to prevent gum deposits from forming 9-Cover the unit and store in a clean, dry place in essential fuel system parts such as the carburetor, out of direct sunlight.
  • Page 26: Trouble Shooting

    TROUBLE SHOOTING Problem Cause Correction 1. Circuit breaker is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord 3. Check and repair. AC output is available. set.
  • Page 27: Parts Diagram And Parts List

    PARTS DIAGRAM AND PARTS LIST P03501 PARTS DIAGRAM...
  • Page 28: Engine Parts Diagram

    FIRMAN 208cc Engine Parts Diagram...
  • Page 29: Parts List

    P03501 Parts List Qty. Qty. NO. Part Number Description NO. Part Number Description FIRMAN 208cc Engine 336713551 Fuel Valve 336713500 Rubber Cap 2 336713552 Guard, Muff. 336713501 Rubber Cap1 336713553 Frame 336713502 Rotor Assy 336713554 Axle Pin 336713503 336713555 Wheel...
  • Page 30 FIRMAN 208cc Engine Parts List NO. Part Number Description Qty. NO. Part Number Description Qty. 336723500 Crankcase Subassembly. 336723553 336723501 Locating Pins 336723554 336723502 Sensor, Engine Oil 336723555 336723503 336723556 Flg. Bolt M6×12 336723504 Camshaft Assy. 336723557 336723505 Bearing 336723558...