Sony FSV-VN7 Installation Manual

Hybrid network fileserver

Advertisement

Quick Links

HYBRID NETWORK FILESERVER
FSV-VN7
FSV-CS7
INSTALLATION MANUAL
1st Edition

Advertisement

Table of Contents
loading

Summary of Contents for Sony FSV-VN7

  • Page 1 HYBRID NETWORK FILESERVER FSV-VN7 FSV-CS7 INSTALLATION MANUAL 1st Edition...
  • Page 2 Ce manual est destiné uniquement aux personnes compétentes en charge de l’entretien. Afin de réduire les risques de décharge électrique, d’incendie ou de blessure n’effectuer que les réparations indiquées dans le mode d’emploi à moins d’être qualifié pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. FSV-VN7/CS7...
  • Page 3: Table Of Contents

    LIB-162 (AIT Library) .......... 3-5 3-2-2. CSM-20 (SAIT Library) ........3-5 3-2-3. Your PC for Webmin Access ........ 3-6 3-2-4. FSV-VN7 (Main Server) ........3-6 3-2-5. FSV-CS7 (Cache Server) ........3-8 3-3. Library Configuration ............. 3-9 3-3-1. License Registration ..........3-9 3-3-2.
  • Page 4: Manual Structure

    Manual Structure Purpose of this manual This is the Installation Manual of Hybrid Network Fileserver FSV-VN7/CS7. This manual describes the information items that premise the service based on the components parts such as introduction, tool and measuring instruments, installation procedure, troubleshooting, assuming use of system and service engineers.
  • Page 5 Cache AIT Library Server ACY-DR162 (AIT Drive) SDX3-100C or SDX4-200C Cleaning Tape Option units STAND BY ERROR MENU ENTER CANCEL Web Administration Screen STAND BY ERROR MENU ENTER CANCEL STAND BY ERROR MENU ENTER CANCEL AIT Library Cache Server FSV-VN7/CS7...
  • Page 6 System Example with SAIT Libraries (CSM-20) Existing LAN Hybrid Network Fileserver (this system) Basic System Management Software Switching Hub Main Server Application Administrator's Server Computer Cache SAIT Library Server ACY-DR20 (SAIT Drive) SAIT1-500 Cleaning Tape Option units Web Administration Screen SAIT Library Cache Server FSV-VN7/CS7...
  • Page 7 List of models Model Name Serial Number Remarks FSV-VN7 (Main Server) LIB-162/A3 (AIT Library) 1,096,001 thru 1,196,021 Up to 4 units connectable 1,362,601 thru 1,382,600 1,382,601 thru 1,387,600 2,478,601 thru 2,479,600 2,479,601 thru 2,480,600 LIB-162/A4 (AIT Library) 2,505,001 thru 2,506,000...
  • Page 9 General tools, such as a screwdriver required to install an HNF, are shown in this list. Tools whose names are displayed in blue have hyper-link to the details of the specification. You may be able to get the equivalent one in your market. Description SONY Parts No. Remarks Torque Drivers and Bits for assembly —...
  • Page 11: Mount

    3-1-2 Configuration 3-2 Setting 3-2-1 LIB-162 (AIT Library) 3-2-2 CSM-20 (SAIT Library) 3-2-3 Your PC for webmin Access 3-2-4 FSV-VN7 (Main Server) 3-2-5 FSV-CS7 (Cache Server) 3-3 Library Configuration 3-3-1 Licence Registration 3-3-2 Verification of Library connection 3-4 System settings...
  • Page 12: Configuration

    Information required for network setup; please obtain the followings from your customer. . Hostname and IP address, Network address, broadcast address and gateway address to be used on the HNF Main Server (FSV-VN7) . SMTP server IP address used for email notification .
  • Page 13 SCSI Cable Not used AIT Library Power Cable Not used Power Cable Cache Server SCSI Cable Not used AIT Library Power Cable Not used Cache Server Power Cable Terminator Power Cable Not used Cache Server Power Cable Option Unit FSV-VN7/CS7...
  • Page 14 Power Cable Power Cable Not used Cache Server SCSI Cable Not used SAIT Library Power Cable Not used Cache Server Power Cable Not used Cache Server Terminator Power Cable Power Cable Not used Cache Server Power Cable Option Unit FSV-VN7/CS7...
  • Page 15: Setting

    TL4 (3rd extra unit) AIT Library reserved for Main Server. Internal Drive1 Internal Drive2 Libraries are assigned from the lowest SCSI ID first to match on display of Management software windows, but SCSI ID 7 is already reserved for the Main Server. FSV-VN7/CS7...
  • Page 16: Your Pc For Webmin Access

    1. Confirm if the installation is successful by the Webmin. From your PC Browser access the following URL. http:// 192.168.1.254:24000 As a login screen should pop up, enter “sony” for User- name, “sony2002” for Password. Click the “Login” button. 1. Disable the Browser Proxy settings.
  • Page 17 Set to a proper address in each box and click “Change global network settings” button. Network address can be changed by updating the configu- ration file by manual. (Refer to 5-2 IP Address change by command line of Appendix) FSV-VN7/CS7...
  • Page 18: Fsv-Cs7 (Cache Server)

    If failed, check the connection of the cache server and the initial settings and try again the above steps. 4. Configuration of the Cache Server Select the [Setup] → [Cache Configuration] icon. When optional Cache Server(s) is(are) connected, repeat the steps of each above procedure. FSV-VN7/CS7...
  • Page 19: Library Configuration

    In this case, check if the value is properly If the Device List is shown in red, the license information typed in. (Refer to Section 4.) may not have been registered correctly. Check the license registration again. FSV-VN7/CS7...
  • Page 20: Verification Of Firmware Revision

    Click the icon and chose the firmware file to upgrade the library. Restart the PetaServe service after upgrade is completed. Webmin: Services → Start/Stop of PetaServe When the firmware matches with the recommended version, the update button becomes invalid. 3-10 FSV-VN7/CS7...
  • Page 21: System Settings

    Do not set the Timezone by using the “setup” command. It may result in an incorrect setting. Do not change the Timezone on the Cache Servers. When the Cache Server needs time settings, go to 3-4-3 Cache Server time settings. 3-11 FSV-VN7/CS7...
  • Page 22: Ntp Setting

    Cache Server time as follows. # date MMDDhhmmYY Example 2004/03/07 15:12 # date 0307151204 Do not change the Timezone on the Caches Server(s). When using the “date” command, use GMT (Greenwich Mean Time) conversion and set the date and time. 3-12 FSV-VN7/CS7...
  • Page 23: Volume Registration

    If time does not permit, insert at least 6 tapes for A3 and 4 tapes for A4. The rest of tapes can be registered in the same way later but before it goes in operation. 5. Click “Operate the library” button. The registration needs about three minutes per tape. 3-13 FSV-VN7/CS7...
  • Page 24: Final Verification Of Volumes

    3. Insert 19 tapes in the slots 1 to 13 and 15 to 20 of SAIT library. If time does not permit, insert at least 4 tapes. 4. Click the “New Volume Insert” button to insert a volume in the mail slot. The registration needs about three minutes per tape. 3-14 FSV-VN7/CS7...
  • Page 25: Final Verification

    Read each message carefully to reconfirm that there is no problem and delete them. If the migration and reload test (described in 3-6-4) are successful, the system should be no problem. 3-15 FSV-VN7/CS7...
  • Page 26 On the client side the default CIFS mount access uses encrypted password, if you prefer to use plain password, you can use this method to modify your settings. Right click on the “DOWNLOAD : stimeout600reg”. And then, following window will appear. 3-16 FSV-VN7/CS7...
  • Page 27: Alert Mail

    “\\43.15.223.195\mfs1” in Folder : space to connect TL1 (AIT Library) . When mounting another Library, change the directly to “\\43.15.223.195\mfs2”. Login as “mfs”, and password is “sonyhnf” to mount the file system. When a new drive appears, Mount is completed. 3-17 FSV-VN7/CS7...
  • Page 28: Migration And Reload To/From Tape And Cache Server

    10. Input the following commands to reload from the tape. [root@sonyhnf TL1]# migreload test [root@sonyhnf TL1]# migls test 11. Check if the symbol “^” is removed from the dis- played. size sgrp file 102400 group1 test 12. Enable the Cache Server by Webmin. 3-18 FSV-VN7/CS7...
  • Page 29: Shutdown Of The Hnf System

    3-6-6. Restart of the HNF System Turn on the units with the following order (for more details, refer to 3-2 Setting) AIT Library(ies) or SAIT Library(ies) → Cache Server(s) → Main Server 3-19 FSV-VN7/CS7...
  • Page 30: Connection Of Ups

    UPS. 3. Connect a dedicated serial cable between the UPS and the serial port on the rear panel of FSV-VN7. 4. Boot the FSV-VN7. The UPS is made available automatically with the default setting.
  • Page 31 1. Check if the IP address for the Cache Server the main server. inputted by Webmin is correct. 2. Check the IP address of the Cache Server by “ifconfig bond0” command in the console. 3. Check if the network cable is connected firmly. FSV-VN7/CS7...
  • Page 32 5. If all the steps above failed, get the Log data and send it to WW service. 3-6-4. Backup and restore to/from If an error occures 1. Check the SCSI connection. Tape and Cache Server 2. Check the error message and find an appropriate action. FSV-VN7/CS7...
  • Page 33: License Agreement

    2. Telnet to the Main Server with the appropriate IP /etc/sysconfig/network-scripts/ifcfg-bond0 address (Eg. : telnet 43.4.148.33) . 3. Login as “sony” with the Password “sony2002”. DEVICE=bond0 4. When a prompt is back, type “su” to go to root account. IPADDR=43.15.223.196 5.
  • Page 35 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 36 FSV-VN7 (SYL) Printed in Japan Sony Corporation FSV-CS7 (SYL) E 2006. 5 08 9-968-286-01 ©2006...

This manual is also suitable for:

Fsv-cs7

Table of Contents