  • Page 1 INSTRUCTIONS FOR USE Shower & Disinfection Panel 04.BC.06_6EN • 08/2019...
  • Page 2 Mandatory to read the Instructions for Use Design Policy and Copyright ® and ™ are trademarks belonging to the Arjo group of companies. © Arjo 2019. As our policy is one of continuous improvement, we reserve the right to modify designs without prior notice.
  • Page 3: Table Of Contents

    Contents Contents ..................3 Foreword ................... 4 Intended Use ................5 Safety Instructions ..............6 Preparations ................7 Product Models ................. 8 Parts Designation ..............10 Product Description/Functions ..........12 Disinfection Flow Control ............. 12 Lockable Door for Disinfectant ..........12 Flow Meter ................
  • Page 4: Foreword

    Foreword Thank you for purchasing Arjo equipment. Shower & Disinfection Panel Definitions in this IFU WARNING Please read this Instructions for Use thoroughly! Instructions for Use (IFU) CAUTION Shower & Disinfection Panel NOTE Serious incident Service and Support Shower &...
  • Page 5: Intended Use

    Instructions for Use (IFU). If there is anything you are not sure about, contact your Arjo representative. Installation & Service Requirements Assembly and Installation Instructions, Care and Preventive Maintenance...
  • Page 6: Safety Instructions

    WARNING Modifications made to the equipment or use of incompatible parts without expressed written consent of Arjo will invalidate the supplier’s product liability. This can compromise the safety of resident and caregiver. WARNING...
  • Page 7: Preparations

    Confirm that responsible organization has established calibration routines. Shower & Disinfection Panel Assembly and Installation Instructions NOTE If you have any questions, please contact your local Arjo representative for support and service. The contact number appears on the last page of this IFU.
  • Page 8: Product Models

    Product Models MODEL 1: With thermostatic mixer for shower and disinfection. BCA 1201-04/1204-04 BCA 1202-04 (GB only) BCA 1207-04 (France only) MODEL 2: With thermostatic mixer for shower and disinfection with flush tank. BCA 1211-04/1214-04 BCA 1212-04 (GB only) BCA 1217-04 (France only)
  • Page 9 MODEL 3: With thermostatic mixer for shower and disinfection with flush valve. BCA 1221-04/1224-04 BCA 1227-04 (France only) Accessory option: Accessory option: NOTE Flush sink with toilet Flush sink made of There are no flush sinks function. stainless steel available for the Shower & Disinfection Panel model 1, since they have no flushing capability.
  • Page 10: Parts Designation

    Parts Designation Shower & Disinfection Panels include the following parts: (BCA 1211-04/1212-04/1214-04/1217-04) (BCA 1221-04/1224-04/1227-04) (Replaces part number1 and 9 on the BCA 1207-04/1217-04/1227-04) (Accessory) (Not available for BCA 1201-04/1202-04/1204-04/1207-04) (Accessory) (Not available for BCA 1201-04/1202-04/1204-04/1207-04)
  • Page 11 BCA1201-04/1202-04/1204-04/1207-04 BCA1211-04/1212-04/1214-04/1217-04 BCA1221-04/1224-04/1227-04...
  • Page 12: Product Description/Functions

    Product Description/Functions Disinfection Flow Control Fig. 1 Lockable Door for Disinfectant Fig. 2 Flow Meter Fig. 3 Shower Flow Control Fig. 4 Shower/Disinfection Handle (France) Fig. 5...
  • Page 13: Shower Flow Control

    Shower/Disinfection Handle (not France) Fig. 6 Lock Button Trigger Temperature Control Fig. 7 Thermometer Fig. 8 Flushing Valve / Flush Button Fig. 9 Shower & Disinfection Panel Flush valve Flush button...
  • Page 14: Shower Patient In A Shower Chair/Trolley

    Shower Patient in a Shower Chair/Trolley Shower & Disinfection Panel Technical Specifications on page 23 Follow these 7 steps. Shower & Disinfection Panel Fig. 1 WARNING To prevent scalding, always check the water temperature with your naked hand before directing the water on the patient. (See Fig. 1) Do not use gloves as it may insulate to the extent that the water temperature can be misjudged.
  • Page 15: Cleaning And Disinfection Instructions

    Iodine, bromide, methylene blue, potassium permanganate etc. (discolouration) Citric acid, chlorine, heavy metal chlorides, petroleum based solvents, trichloroethylene, phenol based disinfectants or similar solvents (damages the plastic surfaces). Do not wash the product with a high pressure washer. Arjo Clean™.
  • Page 16 Microbiological Formation Prevention Installation precautions In order to limit the growth of bacterial flora, it is necessary to take action at four levels: • Avoid stagnating water and ensure proper water circulation; • Take precautions against the formation of scale and corrosion based on to the water quality;...
  • Page 17 CAUTION To prevent equipment surface damage only use Arjo Clean. Fig. 1 Fig. 2 Disinfectant mix ratio Flow Meter Mix Disinfectant Ratio Arjo Clean™ Arjo Plus V Arjo Disinfectant Cleanser IV Cen-Kleen IV™ Arjo General Purpose disinfectant Fig. 3...
  • Page 18 Cleaning & Disinfecting a Shower Chair/ Trolley (8 steps) Shower & Disinfection Panel Technical Specifications on page 23 Fig. 1 WARNING To avoid eye or skin irritation, never disinfect in the presence of a patient. Fig. 2 page 17 Disinfectant mix ratio...
  • Page 19: Care And Preventive Maintenance

    Care and Preventive Maintenance Shower & Disinfection Panel WARNING To avoid malfunction resulting in injury, make sure to conduct regular inspections and follow the recommended maintenance schedule. In some cases due to heavy use of the product and exposure to aggressive environment more frequent inspections should be carried out. Local regulations and standards may be more stringent than the recommended maintenance schedule.
  • Page 20 Caregiver Obligations Fig. 1 Shower & Disinfection Panel Every day page 17 Disinfectant mix ratio Every week Fig. 2 Fig. 3 Fig. 4...
  • Page 21 Monthly Fig. 1 Fig. 2 Fig. 3 WARNING Pressurized system and a risk of scalding. Make sure that the shut-off valve is closed before removing the cap, this is especially important for the hot water shut-off valve.
  • Page 22 Yearly Checks by Qualified Personnel Only WARNING To avoid injury and/or unsafe product, the maintenance activities must be carried out at the correct frequency by qualified personnel using correct tools, parts and knowledge of procedures. Qualified personnel must have documented training in maintenance of this device.
  • Page 23: Technical Specifications

    Technical Specifications Technical Data Measurements, Volume, Weight Weight 14 kg (31 lbs) without flush 22 kg (49 lbs) with flush tank 14 kg (31 lbs) with flush valve Width 455 mm (17 7/8”) without flush 750 mm (29 1/2”) with flush tank 455 mm (17 7/8”) with flush valve Height 510 mm (20”)
  • Page 24 WARNING To avoid injury, always follow the allowed combinations listed in this IFU. No other combinations are allowed. Allowed product combinations The Shower & Disinfection Panels integrate Carendo with the following Arjo products Carevo Carino Carmina Concerto/Basic Prelude Environmental Conditions...
  • Page 25: Labels

    Labels Symbol Explanation Label Explanation Attention Label Identification Label Data Label Water Connection Label...
  • Page 26: Accessories

    Accessories Arjo Clean Flush sink (stainless) Flush sink with toilet For disinfectant contact 080015-53 (P-trap) function local Arjo representative 080015-54 (S-trap) A: Support handle: 100837-04 B: Flush sink: 080090-0453 (P-trap) 080090-0454 (S-trap) C: Support frame: 100836-04...
  • Page 27 AUSTRALIA FRANCE POLSKA Arjo Australia Pty Ltd Arjo SAS Arjo Polska Sp. z o.o. 78, Forsyth Street 2 Avenue Alcide de Gasperi ul. Ks Piotra Wawrzyniaka 2 O’Connor CS 70133 PL-62-052 KOMORNIKI (Pozna ) AU-6163 Western Australia FR-59436 RONCQ CEDEX...
  • Page 28 At Arjo, we are committed to improving the everyday lives of people affected by reduced mobility and age-related health challenges. With products and solutions that ensure ergonomic patient handling, personal hygiene, disinfection, diagnostics, and the effective prevention of pressure ulcers and venous thromboembolism, we help professionals across care environments to continually raise...