Fineco Electric EM737 User Manual

Fineco Electric EM737 User Manual

Smart energy meter

Advertisement

User Manual
Revision 2.003
English
Smart energy meter
EM737 0.5-10(100)A
Shanghai fangqiu electric CO.,LTD.
Shanghai fangqiu electric CO.,LTD.
User Manual EM737
Document code: Fineco737-1-1.1 Revision2.003
Benefits and Main Features
● MID approved with appendix "B" and "D" certification
● Three phase metering ,7 DIN modules
● Direct metering up to 100A
● Accuracy class B according to EN50470-3
● LCD display, 6 integer 2 decimal
● Large clear back light display
● Electrical measurements:
Volts
Amps
kW&kvar&kVA&PF
Frequency
kWh,kvarh
kW& kvar Demand
● Isolate pulse output and IR (DIN43864)
● Optional single-phase model
● RS485 communication port, modbus protocol
● IR port
● Program by button on the nameplate
● Memory back-up (EEprom)
● The meter is intended to be installed in a Mechanical Environment 'M1', with Shock
and Vibrations of low significance, as per 2004/22/EC Directive and should be installed
in Electromagnetic Environment 'E2', as per 2004/22/EC Directive.
L1,L2,L3-N
L1,L2,L3,Σ,Neutral
L1,L2,L3,Σ
+, -, Σ
+, -, Σ
Email:
salesmanager@fineco.cn

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EM737 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fineco Electric EM737

  • Page 1 User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 User Manual Benefits and Main Features Revision 2.003 English ● MID approved with appendix "B" and "D" certification ● Three phase metering ,7 DIN modules ● Direct metering up to 100A Smart energy meter ●...
  • Page 2: Table Of Contents

    User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 Index: 8.6 Pulse output function 9 Programming 1. Safety notice 9.1 Password verify 2. Content of delivery 9.2 ID setting 3. EC Type Examination Certificate 9.3 Baud rate setting 4. Declaration of Conformity...
  • Page 3: Safety Notice

    Document code: Fineco737-1-1.1 Revision2.003 1. Safety notice 3. EC Type Examination Certificate The smart energy meter of EM737 does not require special mechanical or electrical tools for its installation. Mounting position (with any angle of tilt) has no effect on the measurement functions of the meter. Connecting of the meter must be made according to applicable wiring diagram. Incorrect connection of the meter to the electricity network causes major display problem and can also causes serious damage to the meter.
  • Page 4: Declaration Of Conformity

    User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 4.Declaration of Conformity 5.Technical description 5.1 Performance criteria Operating humidity ≤ 75% Storage humidity ≤ 95% Limit range of operating temperature -25°C - +55°C(3K6) Limit range for storage temperature -25°C - +55°C(1K4) Humanity 75% yearly average,95% on 30 days/year International standard EN50470-3 &IEC62053-21...
  • Page 5: Dimensions And Sealing Points

    User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 Power consumption of < 0.01 current circuits(VA) Power consumption of < 1.3W voltage circuits(W) General data Frequency (Hz) Memory back-up EEprom Environment resistance to Terminal 960℃ heat and fire Cover 650℃ upper ABS+PC...
  • Page 6: Wiring Diagrams

    User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 1/2 L1 in & out L2 in & out L3 in & out Neutral test pulse output contact(11-,8+) 8 &11 Active sealing 9&11 Reactive test pulse output contact(11-,9+) Wiring diagrams 12&13 RS485 communication contact(13 TX/RX(-), 12 TX/RX(+))
  • Page 7: Main Function

    Main function 002A/0112 Reactive power L2 8.1 Measuring Function 002C/0114 Reactive power L3 On the EM737 ’S front panel, there are three LED, active/reactive energy pulse light, and 002E/0116 Total reactive power alarm indicator lights . 0030/00D0 Apparent power L1 Meter can measure import &...
  • Page 8: Electricity Parameters Measurement And Monitoring

    User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 0800/0160 Active energy import Symbol Description 0900/0166 kWh—active energy kW—active power Active energy export kVVArh 0A00/0162 kvarh—reactive energy kvar—reactive power Reactive energy import kVA—apparent power 0B00/0168 Reactive Energy export Total Production data and identification...
  • Page 9: Communication Function

    User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 8.4 Communication Function With an infrared COM and a RS485 COM. Its physical layers are independent with each other. One communication channel will not be affected by the other one. The meter can realize data acquisition, broadcast time setting, read, program and manage through hand-held terminals, data acquisition terminal, test equipments and computers.
  • Page 10: Programming

    User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 9.2 ID setting After the Password authentication , the meter will display the “ID XX” setup interface. As the following picture ”Id 00” it means the current ID address is 00 (the ID address is hex code) Press “Page Down” button to decrease the digits. press ”Page Up” to increase the 9 Programming digits,press “SET” button to save the setup, the interface will switch to Baud rate setup...
  • Page 11: Technical Support

    User Manual EM737 Document code: Fineco737-1-1.1 Revision2.003 The meter will display the current password after enter the password setup interface, press the “SET” to change the password. Use “page down” and “page up” button to input password as you want. After 30 seconds the meter will save the password you changed. Remarks: Do not forget the password you setup. Please press the button to check if every setup is correct after the program. Password setup interface “-“ symbol will blink. 10. Technical support Any questions, please contact: TEL: 0086-021-62129691 FAX: 0086-021-62129670 Email: salesmanager@fineco.cn Shanghai fangqiu electric CO.,LTD. Email: salesmanager@fineco.cn...

Table of Contents