7. TECHNICAL DESCRIPTION
7.1. TECHNICAL SPECIFICATION
Dimensions and weight:
•
Width: 48.9 mm [1.92 in]
•
Height: 54.8 mm [2.16 in]
•
Thickness: 15.8 mm [0.62 in]
•
Weight: 50.3 g [1.78 oz]
Depth Gauge:
•
Temperature compensated pressure sensor.
•
Salt water calibrated, in fresh water the readings are about 3% smaller
(calibrated complying with prEN 13319).
•
Maximum depth of operation: 80 m [262 ft] (complying with prEN
13319).
•
Accuracy: ± 1% of full scale or better from 0 to 80 m [262 ft] at 20°C
[68°F] (complying with prEN 13319).
•
Depth display range: 0 ... 99.9 m [300 ft].
•
Resolution: 0.1 m [1 ft].
Temperature display:
•
Resolution: 1ºC [1.5ºF]
•
Display range: - 20 ... +50ºC [- 4 ... +122ºF]
•
Accuracy: ± 2ºC [± 3.6ºF] within 20 minutes of temperature change
67
Need help?
Do you have a question about the D3 and is the answer not in the manual?
Questions and answers