HS 6200 Installation And Operating Instructions Manual

Low voltage control chair

Advertisement

INSTALLATION AND

OPERATING INSTRUCTIONS

OWNERS MANUAL
MODEL 6200
LOW VOLTAGE CONTROL CHAIR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6200 and is the answer not in the manual?

Questions and answers

Summary of Contents for HS 6200

  • Page 1: Operating Instructions

    INSTALLATION AND OPERATING INSTRUCTIONS OWNERS MANUAL MODEL 6200 LOW VOLTAGE CONTROL CHAIR...
  • Page 2 SERIAL NUMBER For your future reference, mark the serial number in the space provided. QUALITY MANAGEMENT SYSTEM REGISTERED TO ISO 9001:2008 ISO 13485:2003 M AD E IN A M E R I C A Reliance® Medical Products • 3535 Kings Mills Road • Mason, Ohio 45040-2303 • 1-800-735-0357 • www.reliance-medical.com...
  • Page 3: Table Of Contents

    #10 Headrest Assembly.........26 3. OPERATION..............7 #11 Headrest Assembly.........28 3.1. Stop Switch.............7 #21 Headrest Assembly.........30 3.2. Chair Lift............8 Wiring Diagram - 6200 .........32 Raising & Lowering the Chair Lift from the Footswitch...............8 LIMITED WARRANTY.............35 3.3. Chair Top............9 Posistioning the Chair Back........9 3.4.
  • Page 4: Important Information

    -30 to +60º C Relative Humidity: Operating: 5%RH to 95%RH without condensation Type B, Applied Part Storage: 10%RH to 100%RH, including condensation Atmospheric Pressure: Operating: 700hPa - 1060hPa Storage: 500hPa - 1060hPa Dangerous Voltage / Shock Hazard Fuse Rating Specification IN-6200...
  • Page 5: Introduction

    1. INTRODUCTION “NOTE”- Note indicates points of particular or 1.1. This manual contains information applicable only additional information. to the Reliance® Model 6200 Chair. « REMARQUE » : Remarque indique des points 1.2. Whenever you see the symbols shown below, d’intérêt particulier ou des renseignements...
  • Page 6: Technical Specifications

    Equipment Model energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices Low Voltage Chair 6200 in the vicinity. However, there is no guarantee that interference Volts Hertz Amps will not occur in a particular installation.
  • Page 7: Installation

    “STOP”. (Refer to Figure 2). cable, and the power cord assembly. Refer to Figure 1 for receptacle location and attach all cables. Footswitch Power Cord & Cable Fusedrawer Chair Control Cable  FIGURE 1 BASE IN-6200...
  • Page 8: Chair Lift

    (Figure 4). • If the chair is equipped with an articulating leg rest, the foot-step and apron will rise when the back is reclined. • In the extreme reclined position these surfaces form a flat table. IN-6200...
  • Page 9: Posistioning The Chair Back

    Chair and that the patient position does not move to an extreme position either toward the head of the Chair or toward the foot of the Chair, since this may result in insufficient stability. IN-6200...
  • Page 10: Footrest

    BLACK DOT place. 3.7. Headrest ACTUATOR 3.7.1. The No. 18 headrest is the standard headrest for the Model 6200 Chair. WARNING- IF THE NO. 18 HEADREST RECEIVES A IMPACT OR STRIKES AN OBJECT WITH FORCE CONTACT RELIANCE® TECH SERVICE IMMEDIATELY.
  • Page 11: Adjustment-No. 11, 21 Headrest

    PROCÉDER À DES INSPECTIONS ÉLECTRIQUES PRÉCAUTION : Pour éviter que le tiroir à OU À DE L’ENTRETIEN. fusible reste bloqué dans le module d’entrée CA, n’installez jamais le tiroir à fusible à l’intérieur du module d’entrée CA sans fusibles. IN-6200...
  • Page 12: Troubleshooting Guide

    (UNDER SEAT BOARD.) CHAIR BACK RECLINES FULLY 1) BACK SPRING FAILURE 1) ADJUST GAS SPRING WITHOUT HANDLE BEING 2) REPLACE GAS SPRING ACTIVATED. CHAIR BACK SPONGY WHEN 1) BACK SPRING FAILURE 1) REPLACE GAS SPRING PATIENT PUTS PRESSURE ON CHAIR BACK. IN-6200...
  • Page 13: Cleaning And Maintenance

    A V E R T I S S E M E N T : S E R É F É R E R areas. AUX DIRECTIVES LOCALES OU DES PROFESSIONS DE LA SANTÉ POUR SÉLECTIONNER DES PRODUITS DE CONTRÔLE D’INFECTION EFFICACES. IN-6200...
  • Page 14: Parts List

    PARTS LIST RELIANCE® MODEL 6200 EXAMINATION AND TREATMENT CHAIR Note: When ordering parts, please: 1. Advise dealer or factory of model and serial number of unit. These numbers are on the plate that is located at rear, near bottom, of chair back.
  • Page 15: Model 6200 Chair Assembly

    Upholstered Back Assembly** 1765073 Scuff Pad** 1479373 Upholstered Seat Assembly** ** Please specify upholstery color when ordering. *Please specify paint color when ordering. To order complete Upholstery Set use P/N. 2727873 Designer Upholstery Set With No. 18 Headrest Pad - 6200 IN-6200...
  • Page 16: Chair Top Assembly

    FIGURE 8 6200 CHAIR ASSEMBLY 6,58 41, 42 9, 10 79, 80 13, 22 64 69 55, 59 69, 73, 74 61, 62, 63 IN-6200...
  • Page 17 Back Hinge Assembly - Right* 0122203 Armrest Bracket - Right* 0603903 Back Hinge Assembly - Left* 0122303 Armrest Bracket - Left* 1/2 Retaining Ring Linkage Pin 0732699 0563299 For Items 46 thru 84 see page 18. *Please specify paint color when ordering. IN-6200...
  • Page 18 4 Circuit Cap 0705199 3/8-16 Nut 1660899 6 Circuit Cap 1586899 6 in Extention Spring 0299899 F.H.M.S. 1/4-20 x 2 1/2 Phil 1655599 6 1/2 in Flexible Tubing Part List for Figure 8 page 16 *Please specify paint color when ordering. IN-6200...
  • Page 19 (NOTES) IN-6200...
  • Page 20: Chair Base Assembly

    FIGURE 9 6200 BASE ASSEMBLY 3, 4 30, 17 30, 17 16, 17 37, 36 IN-6200...
  • Page 21 230V ne comprend pas une fiche. 2716292 Chair Base Assembly - Low - 120V* 2716392 Chair Base Assembly - High - 120V* 2716492 Chair Base Assembly - Low - 230V* 2716592 Chair Base Assembly - High - 230V* *Please specify paint color when ordering. IN-6200...
  • Page 22: Lift Assembly

    FIGURE 10 LIFT ASSEMBLY 33 & 37 IN-6200...
  • Page 23 Pin - Roll (in Item 12) 1060392 Tubing Assembly 0422899 Disc - Valve 1183592 Piston Rod - High 1183692 Piston Rod - Low To order complete Lift Assembly use P/N’s. 2721192 Lift Assembly - Low 2721292 Lift Assembly - High IN-6200...
  • Page 24: Headrest Assembly

    FIGURE 11 # 18 & # 22 HEADREST ASSEMBLY IN-6200...
  • Page 25 2721692 Middle Joint Screw Assembly 144070 #22 Headrest Assembly* Includes: Item’s 5, 6, 7 & 8. *Please specify paint color when ordering. 2721792 Bottom Joint Screw Assembly ** Please specify upholstery color when ordering. Includes: Item’s 5, 6, 8 & 18 IN-6200...
  • Page 26: Headrest Assembly

    FIGURE 12 # 10 HEADREST ASSEMBLY IN-6200...
  • Page 27 F.H.C.S 1/4-20 x 1.00 - Socket 0788699 S.H.C.S. 1/4-20 x 1.00 1454799 B.H.C.S. 1/4-28 x 1/2 To order complete Headrest Assembly use P/N. 665200 #10 Headrest Assembly* *Please specify paint color when ordering. ** Please specify upholstery color when ordering. IN-6200...
  • Page 28: Headrest Assembly

    FIGURE 13 # 11 HEADREST ASSEMBLY 16, 17 10, 17 IN-6200...
  • Page 29 F.H.M.S 3/8-16 x 3/4 0713199 R.H.M.S 1/4-20 x 3/4 0728299 1/4 Lockwasher 1454799 B.H.C.S., 1/4-28 x 1/2 To order complete Headrest Assembly use P/N. 155720 #11 Headrest Assembly* *Please specify paint color when ordering. ** Please specify upholstery color when ordering. IN-6200...
  • Page 30: Headrest Assembly

    FIGURE 14 # 21 HEADREST ASSEMBLY 16, 20 10, 20 IN-6200...
  • Page 31 0845199 F.H.W.S. #6 x 1/2 - Phil 0728299 1/4 Lockwasher 1454799 B.H.C.S., 1/4-28 x 1/2 To order complete Headrest Assembly use P/N. 184640 #21 Headrest Assembly* *Please specify paint color when ordering. ** Please specify upholstery color when ordering. IN-6200...
  • Page 32: Wiring Diagram - 6200

    FIGURE 15 WIRING DIAGRAM IN-6200...
  • Page 33 IN-6200...
  • Page 34 (NOTES) IN-6200...
  • Page 35: Limited Warranty

    REMEDIES ARE LIMITED EXCLUSIVELY TO REPAIR OR REPLACEMENT OF PARTS. RELIANCE® MEDICAL PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE RESULTING FROM THE USE OF THE EQUIPMENT. Claims covered by this warranty will be honored when presented within one (1) month from discovery of a defect. IN-6200...
  • Page 36 MADE IN AMERICA 3535 Kings Mills Road Mason, Ohio 45040-2303 1-800-735-0357(Customer Service) 1-800-735-0358 (Technical Service) (513) 398-3937 Http://www.reliance-medical.com P/N 27168 REV E © Copyright 2006 Printed in U.S.A. Revised 02-2012-7925...

Table of Contents