D
CANopen communication
D.10.1
Object 1010h: Store parameters
The current parameter set (main memory) can be stored in the application parameter set (permanent
memory) through the object. To do this, the object is written with the ASCII text "save" as the hexa
decimal number 65766173h.
The object "Store parameters (1010h_01h)" can only be used with switched-off output
stage.
Index
Name
1010
Store parameters
h
00
Highest sub-index
h
supported
01
Save all parameters
h
Tab. D.45
Objekt 1010
Signature
LSB
ASCII
hex
Tab. D.46 ASCII text "save"
In contrast to the normal SDO traffic, with this object the command is immediately acknowledged at the
start of processing. The internal storage cycle for saving the data can take some seconds. During this
time, no additional SDOs can be processed. Until the internal saving cycle is ended, sent SDOs are
answered with Generic error.
Festo – GDCE-EMCA-EC-C-HP-EN – 1611b – English
Object
code
ARRAY
VAR
VAR
h
s
73
h
Data
Ac
PDO
type
cess
map
ping
–
–
–
UINT8
ro
no
UINT32
rw
no
a
v
61
76
h
Value
Default value
range
–
–
–
1
h
–
1
h
MSB
e
65
h
h
275
Need help?
Do you have a question about the EMCA-EC-67 Series and is the answer not in the manual?
Questions and answers