BEFORE THE FIRST USING YOUR ELECTRIC STORAGE WATER
HEATER, CAREFULLY READ THIS OPERATION MANUAL
Congratulations on your purchase of an electric water heater THERMEX.
Water heaters THERMEX are designed and manufactured in strict accordance
with domestic and international standards guaranteeing operation reliability and safe-
ty.
Present manual applies to THERMEX models of IF/IF (pro). The full name of the
model of your heater is specified in "Manufaturer's warranty" section (sub-section
"Note of sale") and in the marking plate on the heater casing.
Electric water heater (hereinafter referred to as the EWH) is designed to provide
with hot water for domestic and industrial facilities having a cold water supply line
pressure of not less than 0.05 MPa and not more than 0.7 MPa..
EWH shall be operated indoors in heated spaces and it is not designed for opera-
tion in continuous flow mode.
Water heater
Safety valve of GP type
Operation manual
Anchors for fastening (option)
Packaging
EN
EWH power supply shall be within the range of 230 V ± 10%. Supply network
frequency 50 Hz ± 1%. Volume of the inner tank and heating element power are spec-
ified in the marking plate on the casing. Thread diameter in water inlet and outlet
pipes - G1/2 ".
The manufacturer reserves the right to make changes to the design, complete set and
specifications of the heater without prior notice.
DEAR CUSTOMER!
1.
2.
SCOPE OF SUPPLY
3.
MAIN TECHNICAL CHARACTERISTICS
APPLICATION
- 1 pcs.
- 1 pcs.
- 1 pcs.
- 1 set
- 1 pcs.
EN
Table 1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IF 30 V (pro) and is the answer not in the manual?

Questions and answers

Summary of Contents for THERMEx IF 30 V (pro)

  • Page 1 Water heaters THERMEX are designed and manufactured in strict accordance with domestic and international standards guaranteeing operation reliability and safe- Present manual applies to THERMEX models of IF/IF (pro). The full name of the model of your heater is specified in "Manufaturer’s warranty" section (sub-section "Note of sale") and in the marking plate on the heater casing.
  • Page 2: Description And Principle Of Operation

    Model Range EWH useful Average heating time T = Installation volume, l 45° C at 2 kW IF 30 V/ IF 30 V (pro) vertical 0 h 40 min. IF 50 V/ IF 50 V (pro) vertical 1 h 07 min. IF 80 V/ IF 80 V (pro) vertical 1 h 47 min.
  • Page 3 It is required regularly (at least once a month) to discharge a small amount of wa- ter through the exhaust pipe of the safety valve into the drain to remove lime deposits and to test the operating functionality of the valve. Handle (Fig. 1, p. 15) is intended to open the valve.
  • Page 4: Connection To Water Mains

    ARRANGEMENT AND INSTALLATION All installation, plumbing and electrical works shall be performed by qualified personnel. EWH installation shall be performed in accordance with marking on the housing. It is recommended to install EWH as close as possible to the place of hot water using to reduce heat loss in the pipes.
  • Page 5 recommended to connect to a drainage hole a rubber or silicone pipe of the relevant diameter for moisture removal. Connection to the water supply line shall be carried out in accordance with Fig. 1 using copper, plastic pipes or special flexible sanitary wiring. Do not use any used flexible wiring.
  • Page 6: Connection To Power Supply

    10 – hot water main, 11 –cold water shut-off valve, 12 – hot water shut-off valve, 13 – protective cover, 14 –exhaust pipe of the safety valve, 15 – handle for opening pres- sure relief valve, 16 – control panel, 17 – discharge pipe. After connecting EWH make sure that cold water shut-off valve is open and hot water shut-off valve (8) is closed.
  • Page 7: Operation

    OPERATION Figure 2. Electronic control board Figure 2: 1 – LCD display, 2 – button «▲» Temperature control / increasing the heating temperature, 3 – button «▼» Temperature control / decreasing the heating temperature, 4 – button «on/off» / switch on/switch off, 5 – button «Heating mode» / setting the heating power, 6 –...
  • Page 8 can be removed by using scale removing means or mechanically. It is recommended to hold the first technical maintenance after a year from the time of connection by experts of a specialized organization and depending on intensity of scale and residue to determine intervals of follow-up maintenance.
  • Page 9 Heating time covered Remove the flange and increased with a layer of sludge clean the THE Supply voltage decreased Contact power main operation service Frequent tripping The set tempera- Set lower value of water of thermal switch ture is close to the limit heating temperature Thermostat tube is cov- Take out the EWH the re-...
  • Page 10: Manufacturer's Warranty

    TRANSPORTATION AND STORAGE OF ELECTRIC WATER HEATERS Transportation and storage of electric water heaters shall be carried out in accord- ance with manipulation marks on the packaging: need to protect the goods from moisture − fragile, delicate handling − recommended storage temperature range from +10° to +20° С correct vertical position of cargo;...
  • Page 11: Information On The Manufacturer

    EWH. INFORMATION ON THE MANUFACTURER Manufacturer: THERMEX heating Technology (Jiangmen) CO., Ltd No. 51, Jianshedonglu , Taoyuan town, Heshan City, Guangdong Province, China ZIP: 529725 All models have been certified and comply with requirements of European Directives...